Finding | |
|---|---|
| Title | Failure to Perform Adequate NTTF Flooding Walkdowns |
| Description | An NRC-identified non-cited violation (NCV) of 10 CFR 50, Appendix B, Criterion XVI, Corrective Actions, was identified because the licensee failed to identify and correct conditions adverse to quality associated with the flood protection design basis of the Unit 1 Auxiliary Building. Specifically, the licensee failed to identify missing condulet covers in electrical conduits that penetrate the Unit 1 auxiliary building below the flood protection design basis elevation of 154.5 feet (MSL). The inspectors determined that the failure to identify missing condulet covers in electrical conduits that penetrate the Unit 1 auxiliary building below the flood protection design basis elevation of 154.5 feet was a performance deficiency. The discovery of the missing condulet covers was captured in the licensees corrective action program with CR 10273516. The licensee implemented WO SNC815778 to replace missing condulet covers. Corrective actions to inspect the remaining below grade pipe trenches are being developed and scheduled. The performance deficiency was more than minor because it was associated with the protection against external factors attribute of the mitigating systems cornerstone and adversely affected the cornerstone objective of ensuring availability, reliability, and capability of systems that respond to initiating events. Specifically, flood water could enter the Auxiliary Building Lower Equipment Room through unsealed electrical conduits and render the TDAFW Pump inoperable. In accordance with IMC 0609.04, Initial Characterization of Findings, and Exhibit 2 of IMC 0609, Appendix A, The Significance Determination Process (SDP) For Findings At-Power, issued June 19, 2012, the inspectors utilized Section B, External Event Mitigation Systems (Seismic/Fire/Flood/Severe Weather Degraded), and Exhibit 4 of Appendix A and determined the finding did not involve a total loss of any safety function, identified through a PRA, IPEEE, or similar analysis, that contributes to external event initiated core damage accident sequences (i.e., initiated by a seismic, flooding, or severe weather event). The two motor driven AFW pumps are also located in the lower equipment room but are protected behind watertight doors and can satisfy the AFW safety function. Therefore, the finding screened to Green. The inspectors determined the finding had a cross-cutting aspect of Procedures in the human performance area because the licensee missed two opportunities to follow the NEI 12-07 guidance to evaluate the adequacy of the flood protection features below the design basis flood protection elevation.[H.8] |
| Site: | Farley |
|---|---|
| Report | IR 05000348/2016004 Section 4OA2 |
| Date counted | Dec 31, 2016 (2016Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | A Nielsen B Caballero B Collins D Mas J Panfel K Miller P Niebaum S Sandal W Pursley |
| Violation of: | 10 CFR 50 Appendix B 10 CFR 50 Appendix B Criterion XVI |
| CCA | H.8, Procedure Adherence |
| INPO aspect | WP.4 |
| ' | |