05000338/FIN-2012007-02
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Failure To Implement Design Control Measures For The Service Water Air System |
| Description | The team identified a non-cited violation of 10 CFR Part 50, Appendix B, Criterion III, Design Control, for the licensees failure to implement design control measures involving two examples. In the first example, the licensee failed to translate the updated final safety analyses report single failure design bases criteria into the service water (SW) air system specifications. In the second example, the licensee failed to verify the SW air system receiver capacity was adequate to support its design basis function. The licensee entered these issues into their corrective action program as condition reports 477213, 478531, 478957, and 478137. The licensees failure to establish design control measures to translate the updated final safety analyses report single failure design basis criteria into SW air system specifications and failure to verify or check the adequacy of the SW air receiver capacity was a performance deficiency. The performance deficiency was determined to be more than minor because it was associated with the Design Control attribute of the Mitigating Systems Cornerstone and adversely affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, if the screen wash system was required to mitigate the effects of a severe weather initiating event, the performance deficiency could have resulted in a common mode failure of the SW system. In accordance with NRC IMC 0609.04, Initial Screening and Characterization of Findings, the team conducted a Phase 1 Significance Determination Process screening and determined that a Phase 3 assessment was required because the finding screened as potentially risk-significant due to a severe weather initiating event which could plug the SW traveling screens requiring the screen wash function. A bounding Significance Determination Process Phase 3 analysis was performed by a regional senior risk analyst which determined the performance deficiency was a Green finding of very low safety significance. The finding was reviewed for cross-cutting aspects and none were identified since the performance deficiency was not indicative of current licensee performance. |
| Site: | North Anna |
|---|---|
| Report | IR 05000338/2012007 Section 1R21 |
| Date counted | Sep 30, 2012 (2012Q3) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.21 |
| Inspectors (proximate) | G Skinner R Fanner T Tinkel R Nease J Eargle A Alen K Schaaf T Su P Heher |
| INPO aspect | |
| ' | |
Finding - North Anna - IR 05000338/2012007 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (North Anna) @ 2012Q3
Self-Identified List (North Anna)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||