05000323/LER-2006-001, CFR 21 Notification of a Defective Residual Heat Removal Check Valve

From kanterella
Jump to navigation Jump to search
CFR 21 Notification of a Defective Residual Heat Removal Check Valve
ML061290561
Person / Time
Site: Diablo Canyon 
Issue date: 05/01/2006
From: Becker J
Pacific Gas & Electric Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
DCL-06-062 LER 06-001-00
Download: ML061290561 (5)


LER-2006-001, CFR 21 Notification of a Defective Residual Heat Removal Check Valve
Event date:
Report date:
Reporting criterion: 10 CFR 21.21(d)(3)(ii)

10 CFR 50.73(a)(2)(i)

10 CFR 50.73(a)(2)(vii), Common Cause Inoperability

10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded

10 CFR 50.73(a)(2)(viii)(A)

10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition

10 CFR 50.73(a)(2)(viii)(B)

10 CFR 50.73(a)(2)(iii)

10 CFR 50.73(a)(2)(ix)(A)

10 CFR 50.73(a)(2)(iv)(A), System Actuation

10 CFR 50.73(a)(2)(x)

10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor

10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat

10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown

10 CFR 50.73(a)(2)(v), Loss of Safety Function

10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications

10 CFR 21.21(d)(1)
3232006001R00 - NRC Website

text

---

Pacific Gas and Electric Companyo James R. Becker Vice President Diablo Canyon Operations and Station Director Diablo Canyon Power Plant P. 0. Box 56 Avila Beach, CA 93424 805.545.3462 Fax: 805.545.4234 May 1, 2006 PG&E Letter DCL-06-062 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Docket No. 50-323, OL-DPR-82 Diablo Canyon Unit 2 Licensee Event Report 2-2006-001-00 10 CFR 21 Notification of a Defective Residual Heat Removal Check Valve

Dear Commissioners and Staff:

In accordance with 10 CFR 21.21 (d)(3)(ii), Pacific Gas and Electric Company is submitting the enclosed licensee event report regarding the receipt of a defective residual heat removal check valve, a safety-related component.

This condition was initially reported via Event Notification 42459 on March 31, 2006.

This event was not considered risk significant and did not adversely affect the health and safety of the public.

Since ly, James R. Becker ddm/2246/A0661051 Enclosure cc/enc:

Terry W. Jackson, NRC Senior Resident Bruce S. Mallett, NRC Region IV Alan B. Wang, NRC Project Manager Diablo Distribution INPO A member of the STARS (Strategic Teaming and Resource Sharing) Alliance Callaway

  • Comanche Peak
  • Diablo Canyon
  • Palo Verde

WolfC reek Lq

1' r-, T-a

NRC FORM 366 U.S. NUCLEAR REGULATORY COMMISSION APPROVED BY OMB: NO. 3150-0104 EXPIRES: 06/30/2007 (6-2004)

, the NRC may sfor each block) not conduct or sponsor, and a person is not required to respond to, the digits/characters frec blk)information collection.

3. PAGE Diablo Canyon Unit2 05000323 1 OF 4
4. TITLE 10 CFR 21 Notification of a Defective Residual Heat Removal Check Valve
5. EVENT DATE
6. LER NUMBER
7. REPORT DATE
8. OTHER FACILITIES INVOLVED SEUNILRVFACILITY NAME DOCKET NUMBER MONTH DAY YEAR YEAR SEQUENTIAL REV MONTH DAY YEAR 05000 FACILITY NAME DOCKET NUMBER 03 31 2006 2006 - 001 -

00 05 01 2006 05000

9. OPERATING MODE
11. THIS REPORT IS SUBMITTED PURSUANT TO THE REQUIREMENTS OF 10 CFR§: (Check all that apply) 03 20.2201(b)

El 20.2203(a)(3)(i)

El 50.73(a)(2)(i)(C)

El 50.73(a)(2)(vii)

NA E 20.2201(d) 0 20.2203(a)(3)(ii)

El 50.73(a)(2)(ii)(A) 0 50.73(a)(2)(viii)(A)

El 20.2203(a)(1)

El 20.2203(a)(4)

El 50.73(a)(2)(ii)(B)

El 50.73(a)(2)(viii)(B)

El 20.2203(a)(2)(i)

El 50.36(c)(1)(i)(A)

El 50.73(a)(2)(iii)

El 50.73(a)(2)(ix)(A)

10. POWER LEVEL E 20.2203(a)(2)(ii)

El 50.36(c)(1)(ii)(A)

El 50.73(a)(2)(iv)(A)

El 50.73(a)(2)(x)

El 20.2203(a)(2)(iii)

El 50.36(c)(2)

El 50.73(a)(2)(v)(A)

E 73.71(a)(4)

El 20.2203(a)(2)(iv)

El 50.46(a)(3)(ii)

El 50.73(a)(2)(v)(B)

El 73.71 (a)(5)

NA E 20.2203(a)(2)(v)

E 50.73(a)(2)(i)(A)

El 50.73(a)(2)(v)(C) 0 OTHER El 20.2203(a)(2)(vi)

El 50.73(a)(2)(i)(B)

El 50.73(a)(2)(v)(D)

Specify in Abstract below or in NRC Form 366A

12. LICENSEE CONTACT FOR THIS LER LACILiTY NAME Lawrence M. Parker - Senior Regulatory Services Engineer TELEPHONE NUMBER (Include Area Code) 1 (805) 545-3386 El YES (If yes, complete 15. EXPECTED SUBMISSION DATE)

ABSTRACT (Limit to 1400 spaces, i.e., approximately 15 single-spaced typewritten lines)

On March 31, 2006, at approximately 1150 PST, Pacific Gas and Electric Company (PG&E)

Vice President-Diablo Canyon Operations and Station Director, concurred with a quality review determination that a significant defect potentially adverse to safety was identified in a component received from Flowserve, Flow Control Division, of Raleigh, North Carolina. The component is an 8-inch tilting disk check valve, Vendor Assembly Drawing W9023267, that was received for use in the Residual Heat Removal (RHR) System, but not yet installed.

On March 31, 2006, at 1301 PST, PG&E notified the NRC in accordance with 10 CFR 21.21 (d)(1) via Event Notification 42459.

PG&E repaired the valve in accordance with vendor instructions, following which it was successfully bench tested. The valve is scheduled for installation during the Unit 2 Thirteenth Refueling Outage.

PG&E does not know of similar installations at other facilities that are potentially affected by the identified defect, and is providing this report in accordance with 10 CFR 21.21 (d)(3)(ii).

NRC FORM 366(6-2004)

PRINTED ON RECYCLED PAPER NRC FORM 366 (6-2004)

PRINTED ON RECYCLED PAPER

LICENSEE EVENT REPORT (LER) TEXT CONTINUATION FACILITY NAME (1)

DOCKET NUMBER (2)

LER NUMBER (6)

PAGE (3)

YEAR SEQUENTIAL NUMBER REVISION F

INUMBE Diablo Canyon Unit 2 0 l5 0 0 3 l 2 l 3 2006 0 l 0 l 1 1

2 OF 4

TEXT I.

Plant Conditions

Unit 2 did not operate in any plant modes with the described defect installed.

II.

Description of Problem A.

Background

On June 2, 2005, Pacific Gas and Electric Company (PG&E) initiated purchase of an 8-inch tilting disk, stainless steel check valve [CKV], to be built for installation in the Unit 2 Residual Heat Removal (RHR)[BP]

System. The check valves in these locations were initially installed in response to NRC Bulletin 88-04, "Potential Safety Related Pump Loss."

The valve was manufactured by Flowserve, Flow Control Division, of Raleigh, North Carolina, in accordance with Vendor Assembly Drawing W9023267, and ASME Section 111, Subsection NC, 1989 Edition.

Purchase Order No. 125492 was identified as 10 CFR 21 applicable.

B.

Event Description

On March 2, 2006, during post-receipt bench testing, PG&E identified incorrect disc dimensions that caused the disc to stick in the valve bonnet, i.e., in the open position. This defect could have prevented the valve from performing its intended safety function of closing to prevent pump-to-pump interaction when both RHR pumps are running.

On March 8, 2006, PG&E notified Flowserve of the defect via Supplier Audit Finding Report No. 060670010, and requested corrective actions be taken.

On March 13, 2006, Flowserve concluded that the defect was caused by disc design error and test procedure error.

On March 16, 2006, Flowserve initiated Quality Problem Corrective Action Plan No. 169, that concluded a 10 CFR 21 evaluation was not required.

On March 31, 2006, the PG&E Vice President - Diablo Canyon Operations and Station Director, concurred with a quality review determination that a significant defect potentially adverse to safety had been identified in a component received for use in a safety-related application for Unit 2.

LICENSEE EVENT REPORT (LER) TEXT CONTINUATION FACILITY NAME (1)

DOCKET NUMBER (2)

LER NUMBER (6)

PAGE (3)

YEAR SEQUENTIAL NUMBER REVIUSM N

DiabloCanyon Unit 2 0

5 0 0 3 12 13 200 O

0 1 0 1 3 1OF [ 4 TEXT On March 31, 2006, at 1301 PST, PG&E notified the NRC in accordance with 10 CFR 21.21 (d)(1) via Event Notification 42459.

C.

Inoperable Structures, Systems, or Components that Contributed to the Event None.

D.

Other Systems or Secondary Functions Affected

None.

E.

Method of Discovery

This condition was identified during post-receipt bench testing.

F.

Operator Actions

None.

G.

Safety System Responses None.

Ill.

Cause of the Problem A.

Immediate Cause The defect identified involved incorrect valve disc dimensions that caused the disc to stick in the valve bonnet, in the open position.

B.

Root Cause The vendor concluded that the cause of the incorrect valve disc dimensions was design error.

C.

Contributory Cause The vendor's test procedure did not test the valve with the bonnet installed.

LICENSEE EVENT REPORT (LER) TEXT CONTINUATION FACILITY NAME (1)

DOCKET NUMBER (2)

LER NUMBER (6)

PAGE (3)

YEAR SEQUENTIAL NUMBER REVISION NUMBER Diablo Canyon Unit20 l5 0 0 0 3 2 3 2006 0

l 0 1 l -

0 1 4 I OF I 4 TEXT IV.

Assessment of Safety Consequences

The identified defect could have prevented the valve from performing its intended safety function of closing to prevent pump-to-pump interaction when both RHR pumps are running. Failure of this check valve, had it been installed, could have resulted in the loss of one RHR train on Unit 2, which could impact the ability to shut down the reactor and maintain it in a safe shutdown condition.

The defect was identified during bench testing prior to installation, thus, the defect was prevented from being placed in service. If the defect had not been previously identified, PG&E's Inservice Testing Program requires that the valve be full flow and reverse flow verified prior to declaring the system operable.

Therefore, this event was of very low risk significance, was not a Safety System Functional Failure, and did not adversely affect the health and safety of the public.

V.

Corrective Actions

A.

Immediate Actions

1. Bench testing activities were stopped, a problem report was initiated, and the vendor notified.
2. Supplier Audit Finding Report No. 060670010 was issued to Flowserve.

B.

Corrective Actions

PG&E repaired the valve in accordance with vendor instructions.

VI.

Additional Information

A.

Failed Component: 8-inch tilting disk stainless steel check valve.

Manufacturer:

Flowserve; PG&E Purchase Order No. 125492 Flow Control Division, Raleigh, North Carolina

Reference:

Vendor Assembly Drawing W9023267, Part Serial No. AY777 ASME Section III, Subsection NC, 1989 Edition B.

Previous Similar Events

None.