Finding | |
|---|---|
| Title | Inadequate Test Control of Safety Related Batteries |
| Description | The team identified a finding of very low safety significance involving a non-cited violation of 10 CFR 50, Appendix B, Criterion XI, Test Control, in that, Constellation did not assure that required testing was performed in accordance with written test procedures and that test results were documented and evaluated to verify that test . requirements were satisfied. Specifically, there were instances where Constellation did not correctly calculate battery capacity, record battery voltages, and properly load the battery during the 11 and 21 station battery discharge tests. In response, Constellation entered the issue into the corrective action program and determined that there was sufficient battery margin to assure operability of the station batteries. The finding is more than minor because it is associated with the procedure quality attribute of the Mitigating Systems Cornerstone and affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. The team determined the finding was of very low safety significance (Green) because it was not a design or qualification deficiency, did not represent a loss of system safety function, did not represent an actual loss of safety function of a single train, and did not screen as potentially risk significant due to a seismic, flooding, or severe weather initiating event. This finding has a crosscutting aspect in the area of Human Performance, Resources Component, because Constellation did not ensure that complete, accurate, and up-to-date procedures were available and adequate to assure nuclear safety. Specifically, the battery discharge test procedures did not ensure that capacities were correctly calculated, critical voltages were recorded, and battery test loading parameters were correct. (IMe 0305, Aspect H.2(c) |
| Site: | Calvert Cliffs |
|---|---|
| Report | IR 05000317/2009006 Section 1R21 |
| Date counted | Sep 30, 2009 (2009Q3) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.21 |
| Inspectors (proximate) | J Lilliendahl S Pindale C Baron G Skinner F Arner L Doerflein M Halter |
| CCA | H.7, Documentation |
| INPO aspect | WP.3 |
| ' | |
Finding - Calvert Cliffs - IR 05000317/2009006 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Calvert Cliffs) @ 2009Q3
Self-Identified List (Calvert Cliffs)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||