05000302/LER-1977-161, E/04X-0:on 771229-30,biomass of Fish & Shellfish Impinged on Intake Screens,Exceeding ETS Limits.Partially Caused by Oil Barge Entering Intake Canal During Sampling. Entire Scaled Sardine School May Have Been Trapped

From kanterella
(Redirected from 05000302/LER-1977-161)
Jump to navigation Jump to search
E/04X-0:on 771229-30,biomass of Fish & Shellfish Impinged on Intake Screens,Exceeding ETS Limits.Partially Caused by Oil Barge Entering Intake Canal During Sampling. Entire Scaled Sardine School May Have Been Trapped
ML19317G136
Person / Time
Site: Crystal River 
Issue date: 01/18/1978
From:
FLORIDA POWER CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19317G131 List:
References
CS-78-20, LER-77-161E-04X, LER-77-161E-4X, NUDOCS 8002270843
Download: ML19317G136 (1)


LER-1977-161, E/04X-0:on 771229-30,biomass of Fish & Shellfish Impinged on Intake Screens,Exceeding ETS Limits.Partially Caused by Oil Barge Entering Intake Canal During Sampling. Entire Scaled Sardine School May Have Been Trapped
Event date:
Report date:
3021977161R00 - NRC Website

text

.

O ENVIRONMENTAL LICENSEE EVENT REPORT 77-161E/04X-0 0s 1.

Facility:

Crystal River hit #3 2.

Report Date:

18 January 1978 3.

Occurrence Date:

29-30 December 1977 (determined at plant 17 January 1978) 4.

Identification of Occurrence:

Biomass of fish and shellfish impinged on the intake screens of Units 1, 2, and 3 exceeded the 50 kg/24 hour reporting level of Section 3.1.3 of the Environmental Technical Specifications.

5.

Conditions Prior to Occurrenca:

4 hit il - All water circulation pumps operational.

hit #2 - All water circulation pumps non-operational (unit down) hit #3 - All water circulation pumps operational.

6.

Description of occurrence:

During the period 0900 29 December 1977 to 0900 30 December 1977, 828.02 kg of fish and shellfish were impinged on the intake screens at Crystc1 River Units 1, 2, and 3.

Of the 828.02,kg impinged, Unic #3 accounted for 761.63 kg (92 of total). Three finfish species accounted for 94% of the total biomass; scaled sardine 647.17 kg (78%), batfish 74.51 kg (9%), and the Atlantic thread herring 57.38 kg (7%). The remaining biomass impinged was distributed among several species of fish and shellfish.

7.

Designation of Apparent Cause of Occurrence:

)

The following unusual or periodic events were noted prior to, or during, the occurrence-i 1.

One oil barge entered the intake canal during the sempling period.

2.

The scaled sardine is a schooling fish. It is possible that an entire school was entrapped in the intake canal and subsequently impinged.

Thess events may have been partially responsible for the impingement observed.

/rc 8002 270

}

I