05000286/FIN-2009003-02
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Inadequate Maintenance Procedures on FRVs Resulted in a Manual Reactor Trip |
Description | A self-revealing finding of very low safety significance was identified because Entergy personnel did not have adequate procedures appropriate for maintenance associated with air-operated valves. Specifically, existing Entergy maintenance procedures did not ensure that the 33 steam generator (SG) feedwater regulating valve (FRV) positioner feedback arm connecting linkage hardware was properly secured following maintenance. As a result, on May 15,2009, this linkage became disconnected which led to SG level oscillations that required a manual reactor trip by control room operators. Entergy personnel repaired the valve positioner feedback arm connecting linkage, identified the main cause during a post-transient review, performed extent of condition inspections on similar valves susceptible to the same linkage deficiency, and completed a root cause analysis within the corrective action program under condition report (CR)-IP3-2009-02368.The inspectors determined the finding is more than minor because the finding is associated with the equipment performance attribute of the Initiating Events cornerstone and affected the cornerstone objective to limit the likelihood of those events that upset plant stability and challenge critical safety functions during shutdown as well as power operations. Specifically, the inadequate procedures resulted in the failure of a non-safety-related portion of the 33 SG FRV and resulted in a manual reactor trip. The inspectors evaluated the significance of the finding using IMC 0609, Attachment 4, and determined this finding did not contribute to both the likelihood of a reactor trip and the likelihood that mitigation equipment or functions would be unavailable. Consequently, the finding is of very low safety significance. The inspectors determined that this finding had a cross-cutting aspect in the area of Human Performance because Entergy staff did not ensure that complete, accurate and up-to-date procedures were available to perform appropriate maintenance on air-operated valve positioners associated with the 33 SG FRV. |
Site: | Indian Point ![]() |
---|---|
Report | IR 05000286/2009003 Section 4OA7 |
Date counted | Jun 30, 2009 (2009Q2) |
Type: | Finding: Green |
cornerstone | Initiating Events |
Identified by: | Self-revealing |
Inspection Procedure: | |
Inspectors (proximate) | O Ayegbiso S Mccarver C Hott D Johnson E Huang G Malone J Noggle M Gray |
CCA | H.7, Documentation |
INPO aspect | WP.3 |
' | |
Finding - Indian Point - IR 05000286/2009003 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Indian Point) @ 2009Q2
Self-Identified List (Indian Point)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||