Finding | |
---|---|
Title | Failure to Include RWST Level Maintenance In Online Risk Assessment |
Description | The inspectors identified a NCV of very low safety significance related to 10 CFR50.65(a)(4), because Entergy personnel did not adequately assess the risk associated with the unavailability of the Refueling Water Storage Tank (RWST) level indication during planned maintenance on the level transmitters and instrumentation. Entergy entered the issue into the corrective action program (CR-IP2-2009-00342), updated the risk model to include the maintenance activity, assessed the risk, and appropriately coded the maintenance activity to ensure it would be risk assessed in the future. The inspectors determined that this finding was more than minor because it was a maintenance risk assessment issue in which personnel did not consider risk significant SSCs that were unavailable during maintenance. The RWST level indication is specifically listed in Table 2 of the plant specific Phase 2 SDP risk-informed inspection notebook. The inspectors determined the significance of this issue in accordance with IMC 0609, Appendix K, Maintenance Risk Assessment and Risk Management Significance Determination Process. The inspectors determined that this finding was of very low safety significance because the Incremental Core Damage Probability Deficit was less than 1E-6.The inspectors determined that the finding had a cross-cutting aspect in the area of human performance related to work control. Specifically, Entergy personnel did not appropriately plan work activities by incorporating risk insights for affected plant equipment. (H.3(a) per IMC 0305 |
Site: | Indian Point |
---|---|
Report | IR 05000247/2009002 Section 1R13 |
Date counted | Mar 31, 2009 (2009Q1) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.13 |
Inspectors (proximate) | C Hott G Malone J Commiskey M Gray |
CCA | H.5, Work Management |
INPO aspect | WP.1 |
' | |
Finding - Indian Point - IR 05000247/2009002 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Indian Point) @ 2009Q1
Self-Identified List (Indian Point)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||