o NSF NORTHERN STATES POWER COMPANY M I N N E A PO LI S. M I N N E S OTA 55401 January 18, 1980 Mr J G Keppler Office of Inspection & Enforcement U S Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137

Dear Mr Keppler:

PRAIRIE ISLAND NUCLEAR GENERATING PLANT Docket No. 50-282 License No. DPR-42 Both Trains of Caustic Addition Valved Out by Mistake The Licensee Event Report for this occurrence is reproduced on the back of this letter and in the attached supplemental report.

Enclosed are three copies.

This event is reported in compliance with Technical Specification 6.7.B.1.f in that personnel error and procedural inadequacy resulted in operation for a short period of time without automatic caustic addition to the containment spray system.

Yours very truly, c..' C kwa p o%

L 0 Mayer, PE Manager of Nuclear Support Services LOM/DMM/jh cc:

Director, IE, USNRC (40)

Director, MIPC, USNRC (3)

MPCA Attn: J W Ferman 1783 321

- over-8001220