Finding | |
---|---|
Title | Failure to Positively Control Compensatory Measures |
Description | The inspectors identified a finding of very low safety significance and a Non-Cited Violation of 10 CFR Part 50, Appendix B, Criterion V on April 28, 2009, for failure to have adequate procedures to control compensatory actions for degraded/nonconforming conditions. Specifically the failure to implement positive controls for the Unit 2 roll-up door as a compensatory measure for an operability determination invalidated the determination. The door was discovered less than the 18-open requirement which supported the flooding evaluation. Corrective actions for this issue included opening the Unit 2 turbine building roll-up door to greater than 18 inches open, implementing positive configuration controls for the compensatory measures, and revising the operability determination procedure to require the implementation of positive controls. The inspectors determined that this finding was more than minor because if left uncorrected the failure to properly control compensatory measures could result in rendering equipment inoperable (a more significant safety concern). This finding was of very low safety significance because it was not a design or qualification deficiency, did not result in a loss of system safety function or the loss of a single train for greater than the Technical Specification allowed outage time, and it did not screen as potentially risk significant due to a seismic, flooding, or severe weather initiating event since the roll-up door was 14 inches open and would have provided some mitigation following an internal flooding event. The inspectors determined that this issue was cross-cutting in the Human Performance, Resources area because the licensee failed to ensure that the operability determination procedure was adequate in regards to the control of compensatory measures (H.2(c)). (Section 1R15.1b(1) |
Site: | Prairie Island |
---|---|
Report | IR 05000282/2009003 Section 1R15 |
Date counted | Jun 30, 2009 (2009Q2) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.15 |
Inspectors (proximate) | D Betancourt J Giessner J Neurauter K Stoedter M Phalen P Zurawski R Jones |
CCA | H.7, Documentation |
INPO aspect | WP.3 |
' | |
Finding - Prairie Island - IR 05000282/2009003 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Prairie Island) @ 2009Q2
Self-Identified List (Prairie Island)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||