05000282/FIN-2008007-01
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Failure to Perform a 10 CFR 50.59 Evaluation for Bulk Hydrogen Storage Facility |
| Description | The inspectors identified a Severity Level IV NCV, having very low safety significance, of 10 CFR 50.59, Changes, Tests, and Experiments, for the licensees failure to perform a safety evaluation associated with installation of a bulk hydrogen storage facility. Specifically, the licensee had not evaluated the adverse affects on the Circulating Water System from a postulated hydrogen tank explosion in the bulk storage facility located directly above buried Circulating Water System return lines. The licensee stopped work on the installation of the bulk hydrogen facility and documented the NRC identified issues in the corrective action system. The inspectors concerns also prompted the licensee to identify above ground Cooling Water System pipe in the nearby Turbine Building, which had not been evaluated in the hydrogen blast analysis. The finding was more than minor because the inspectors could not reasonably determine that this change would not have ultimately required prior approval from the NRC. This finding was categorized as Severity Level IV because the underlying technical issue for the finding was determined to be of very low safety significance based on a Phase 1 screening in accordance with IMC 0609, Appendix A, Significance Determination of Reactor Inspection Findings for At-Power Situation. Specifically, the inspectors answered No to the Mitigating Systems screening questions in the Phase 1 Screening Worksheet because the licensee had not yet filled the bulk storage facility with hydrogen, so no possibility of explosion and damage to plant equipment existed. The cause of the finding is related to the cross-cutting element of Human Performance Decision Making, because the licensee failed to make conservative assumptions in decision making associated with the effects of a postulated hydrogen tank explosion (IMC 305, Section 06.07.c, Item H.1(b)). (Section 1R17.1.b |
| Site: | Prairie Island |
|---|---|
| Report | IR 05000282/2008007 Section 1R17 |
| Date counted | Dec 31, 2008 (2008Q4) |
| Type: | TEV: Severity level IV |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.17 |
| Inspectors (proximate) | M Holmberg M Munir V Meghani |
| CCA | H.14, Conservative Bias |
| INPO aspect | DM.2 |
| ' | |
Finding - Prairie Island - IR 05000282/2008007 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Prairie Island) @ 2008Q4
Self-Identified List (Prairie Island)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||