Finding | |
|---|---|
| Title | 11 Turbine-Driven Auxiliary Feedwater Pump Inoperable Due to Improperly Installed Insulation |
| Description | The inspectors identified an apparent violation (AV) of Technical Specification 5.4.1 for the failure to establish, implement and maintain procedures governing the installation of insulation on the 11 turbine-driven auxiliary feedwater (TDAFW) pump. The failure to establish and implement adequate instructions resulted in the 11 TDAFW pump being inoperable for 10 days due to improper insulation installation during the March 2008, Unit 1 refueling outage. This issue has the potential to have low to moderate safety significance; however, this may change pending the completion of the SDP. Corrective actions for this issue included correctly installing the insulation, exploring the installation of a different insulation package that was easier to install, and performing an internal inspection to determine if mechanical clearances inside the turbine were contributing to the increased turbine bearing temperatures. This finding was more than minor because it was associated with the equipment performance attribute of the Mitigating Systems Cornerstone and affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the 11 TDAFW pump would not have been able to perform its safety function during the worst case, post-accident conditions. This finding was not an immediate safety concern because the licensee took immediate action to declare the pump inoperable once the condition of the insulation was identified. The inspectors determined that this finding was cross-cutting with respect to the Decision Making aspect of the Human Performance area because the licensee failed to use conservative assumptions when determining the need to establish and implement instructions for installing the turbine insulation (H.1(b)). (Section 4OA5.3 |
| Site: | Prairie Island |
|---|---|
| Report | IR 05000282/2008004 Section 4OA5 |
| Date counted | Sep 30, 2008 (2008Q3) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | |
| Inspectors (proximate) | C Zoia E Dickson K Stoedter L Kozak M Munir M Phalen P Zurawski R Skokowski S Thomas |
| CCA | H.14, Conservative Bias |
| INPO aspect | DM.2 |
| ' | |
Finding - Prairie Island - IR 05000282/2008004 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Prairie Island) @ 2008Q3
Self-Identified List (Prairie Island)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||