05000280/LER-2078-028-03, L-0 for Surry 2 Re Containment Pressure Exceeded Allowable Limit
| ML19105A301 | |
| Person / Time | |
|---|---|
| Site: | Surry |
| Issue date: | 09/01/1978 |
| From: | Stallings C Virginia Electric & Power Co (VEPCO) |
| To: | O'Reilly J NRC/RGN-II |
| References | |
| Serial No. 498 LER 1978-028-03L-0 | |
| Download: ML19105A301 (4) | |
| Event date: | |
|---|---|
| Report date: | |
| 2802078028R03 - NRC Website | |
text
--~--~-... ----:;
'"~:-
. ' ' _:.'~..
1 * :: ; * *" *. :;.:. )1.*:}11'.*,o;i,C:*:..
- . \\.
. _':~.: :
1atdli(afojy_~n.acKEf:".f1it'~C:OP~.-'-
..,.,.. *:,Yt~;
1tatJi:;l~~~~ttr:;Jf it)i.?'.**:,:i\\iC *:L:}*
. :. -.,- -*, ::. S~ptember:.1,.J 978 :
.-:.*....\\,*._*.. "*'.:: ~:-:.
,.,. 'hS'";....*..... *.....,~I:,i:./~:/+~~**
- . '.- **:-,Mr. Jeau P. *O.'D.eilly, Director***.,... -..,.--
- :;,':... <- Serial-_ND/,498
- :*i:!;~.ft~~~~:,*** *J=DI.11:6~~!~~>>*.. < :*.
- ~
.r.*....
,.*_. ~*
" :,. ~
. :* 101*-Ma:f.etta Strut -.-:Bli:ite :lUK>,. * :-
...... ***::**:~i;ri~~.s~~.;~;~i*'~::;:.. ~.v~~*
- . : ***.*.* ~\\'** *. ;.:,,**
'*.. *- *. * * *. **-*EUctr:lc:and fonr -~~_: ~~a\\:,\\liubuta.. th* *to"Uoid.n& :Licwu*.. :~t:-;hpon* * *. __ **: **.. '_ **.
>):,:
/('. :? >! :'}{;' '.. '. *.*.
.i idin~ca*
- t
- if ?f
- lur'.S, ltt*:._.I
- :*... *:*
- Office_:; o1* Managawit;.'~9DtAt1-: < * *, ~- * * *. *
- ad. hoin:a.. Con'tnl
',,,**,I * ;.
' : ~. :* >- :
,,,* -';t
'--/;'.
~:.
- I,,,::*.T~-~~-'
,_1
- 1 7c:24ao124
.,. **: --~ -
.. '.. :.,_ ':,;~'.
\\:,**.... ~-
-~*.,1
- r.,
.. * ':}:\\v~t<*,:t).**
.. ;... *.* '?.,.. **..
~,:* ~:: *._, }*; '. :- :...
NRC FORM 366 (7-77)
U.S. NUCLEAR REGULATORY COMMISSION.
e LICENSEE EVENT REPORT e CONTROLBLOCK: ~'-.L--_..L_...__.__ _ _.__.IG) 1 6
(PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION)
, v r A I s I p I s 1 2 101 a, a 1 - 1 a I a I a I a I a 1 _, a, 9
LICENSEE CODE 14 15 LICENSE NUMBER
~
7 8
0101 41 11.11 111 101 I 10 25 26 LICENSE TYPE 30 57 CAT 58 CON'T ITITI 7
8
~~~~~~ ~© I o I s I o -I o I o I 2 I s l 1 101 o I s I o I JI z I s 101 ° 18 13 I 11 7 I s I G) 60 61 DOCKET NUMBER 68 69 EVENT DATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES@
!During normal operation the containment partial pressure exceeded the allowable limit*
~
las specified in the Surry Unit 1 and 2 Order for Modification of License, dated June
~
129, 1978.
This event is reportable as per Technical Specifications 6.6.2~b.(2).
The OD}] !health and safety of the general public were not affected.
[11§]
CIT?]
[§JI]
- 7 8 9.
E£::m 7
8 SYSTEM CODE
,s I Bl@
9 10
- 0. LER/RO CVENT YEAR
~
REPORT I 7 j 8 /
NUMBER 21 22
CAUSE
CAUSE CODE SUBCODE COMPONENT CODE
~@ ~@ I z I z I z I z I z I z 18 11 12 13 18 SEQUENTIAL OCCURRENCE REPORT NO.
CODE 10121s1 I/I fol 3/
23 24 26 27 28.
29
. COMP.
SUBCODE
~@)
19 REPORT TYPE l1_J 30 VALVE SUBCODE
~@
20 ACTION FUTURE EFFECT SHUTDOWN r::::,.
ATTACHMENT NPRD-4 31 PRIME COMP.
SUPPLIER REVISION NO.
IJLJ 32 COMPONENT MANUFACTURER 80 TAKEN ACTION ON PLANT METHOD HOURS ~ SUBMITTED FORM SUB.
Li@L£.I@ ~@ ~
I. 0 I o I o I o I W@ ~@
33 34 35 36 3 7 40 41 42 w@ I z I 9 I 9 I 9 I@
CAUSE DESCRIPTION AND CORRECTIVE ACTIONS @
43 44 47
~he event was caused by a small leak in the Containment Radiation Monitoring Syst£ID, ITJJ] jContairunent partial pressure was reduced using the containment vacuum pumps.
OE.)
7 8
9 FACILITY STATUS
% POWER OTHER STATUS [QI] LU@ 11 I O I 01@1......_ __
._NA __
@)
7 8
9 10 12 1'.3 44 ACTIVITY CONTENT Q
RELEASED OF RELEASE AMOUNT OF ACTIVITY
~
LU@) ~@)I NA 7
B 9
10 11 PERSONNEL EXPOSURES r:;;;.,
44 80 METHOD OF A
DISCOVERY DISCOVERY DESCRIPTION ~
l..!J~~L ___
O~p_e_r_a_t_o_r_O_b_s_e_rv a_t_i_o_n _______ __.
45 46 45 LOCATI0°N OF RELEASE @
NA 80 J
80 NUMBER
~
TYPE
DESCRIPTION
[IE] 1° 1° I ~0tU@,___ ____
NA ___________________
7 8
9 11 12 13 PERSONNEL INJURIES Q
80 NUMBER DESCRIPTION~
ETIJ I O j O l O l@'---_. ______
N_A ___________________
- - J 7
8 9
11 12 80 LOSS OF OR DAMAGE TO FACILITY '43',
TYPE
DESCRIPTION
~
EJ2) ~{§)'---~~~~~~~NA~~~~~~~~~~~~~~~~~~~~~~------1 7
8 9
10 80 PUBLICITY
~
NRC USE ON y ISSUEDQ DESCRIPTION~
L
,o [IG] LBJ~....._ _____
NA ________________ __.
L I II II I I II I I I ~
7 8
9 10 68
- 69.
80 ;
T*. L. Baucom NAME OF PREPARER------------------
PHONE; __
( 8_0_4-'-)_3_5 7_-...:3c....::1=8'-'4 __ _
0
- 0.
C)
, 5urry Power Station, Unit 2 Docket No: 50~281 Report No: 78-028/03L-0 Event Date: 08-03-78 Title of Report:
Containment Partial Pressure
- 1.
- 2.
Description of Event
During normal operation the containment partial pressure exceeded the allowable limit as specified in the Surry Unit 1 and 2 Order for Modifica-tion of License dated June 29, 1978.
At the time of the event, the service water temperature was 85°F and the Refueling Water Storage Tank temperature was less than 45°F.
The partial pressure limit was exceeded by 0.05 psia before corrective action returned the pressure within the limits.
This event is reportable as per Technical Specifications 6.6.2.b.(2).
Probable Consequences and Status of Redundant Systems The containment pressure must be maintained below a specified limit in order to insure adequate conservatism in the ECCS performance as analyzed in the FSAR.
A margin of partial pressure is permitted (not to *exceed 0.25 psi) to sustain operation while action is taken to correct a problem.
If the condition cannot be corrected, the reactor must be shutdown.
Containment* pressure remained within the allowable limits at all times,.
and pressure instrumentation.remained operable and capable of CLS initiation.
The health and safety of the general public were not affected.
- 3.
Cause
This event was caused by a small leak in the containment radiation moni-toring system and abnormally high ambient temperatures causing the containment
.to heat up and pressurize more rapidly than normal following unit startup.
- 4.
Immediate Corrective Action
- 5.
A second vacuum pump was started and a search for leaks initiated.
When found, the leaking fittings on the containment radiation monitoring system were tightened.
As the containment bulk average temperature reached equilibrium, the containment vacuum system brought the partial pressure with-in the limits and the second vacuum pump was returned to standby.
Subsequent Corrective Action No further corrective action was required.
- 6.
Actions Taken to Prevent Recurrence A modification to improve containment cooling systems has.been initiated, approved, and is planned for installation during the Steam Generator Replace-ment,Outage.
During periods of high service water temperature (>87°), con-
. tainment pressure, temperature and service water conditions are.monitored
Surry Power Station, Unit 2
,,, r!ocket No: 50-281 Report No: 78-028/03L-0 Event Date: 08-03-78 Title of Report:
Containment Partial Pressure (Continued)
- 7.
on a more frequent interval.
Generic Implications None