05000280/LER-1980-063-01, Vascomax Cap Screw in Steam Generator a Leveling Pads Broke During Disassembly. Caused by Stress Corrosion Cracking.Screws Replaced

From kanterella
(Redirected from 05000280/LER-1980-063-01)
Jump to navigation Jump to search
Vascomax Cap Screw in Steam Generator a Leveling Pads Broke During Disassembly. Caused by Stress Corrosion Cracking.Screws Replaced
ML18139B157
Person / Time
Site: Surry 
Issue date: 03/09/1981
From: Joshua Wilson
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML18139B155 List:
References
LER-80-063-01X, LER-80-63-1X, NUDOCS 8103130477
Download: ML18139B157 (2)


LER-1980-063, Vascomax Cap Screw in Steam Generator a Leveling Pads Broke During Disassembly. Caused by Stress Corrosion Cracking.Screws Replaced
Event date:
Report date:
2801980063R01 - NRC Website

text

CONTROL BLOCK: I I

I Ii'

,!---------------"'!!fl \\.!.I (Pl.EASE PRINT CA TYPE ALL ~EQUIREC INFORMATtONI-

!IE]_ Iv I A I s I PI sl 1 101 o j.o.J -I o I 01 01 01. oj. -I 01 o 1@1*4-I l 11 I 111101 I I© i3 9

UCENSEE CQCE.

  • 1.&

~S.

Uc&NSENUMBER 25..

25 L.ICENSE TYPE

JO 57 CAT 58 CON'i' [IQ]

8

---:~~i ~J-9.I. sJ.,OJ o !.. OL,ZI a.!o. lQ)t1l1 11 12 ! s Io !©Io I 3:! o I 9 I a 111@.

6Q 61.

CCCK&T NUMBER 68*

69 EVENT CATE 74 75 REPORT CA'l"E 80

VENT CESCrUPTION*ANC PROBABLE CONSEQUENCES@

((II] I During disassembly of "A" Steam Generator Leveling Pads. in accordance with*ETA C!JI]..J

  • 30017 ~ a Vascomax cap screw was broken.
  • The screw had been loosened and was being

([JILi turned out when it failed.. Preliminary investigation revealea *the failure_ h@sL C[II].

  • 1 begun be£ ore removal..

This event. is reportable as per Technical Specification 1.... --

[]JD 1....~6~*:.i* 6~-~2:..:**:.:;*a:.:*:..iCi..:9:..il~*-...1To;,1JJ;e:..1,hLieaawl,.t..1.b1..1iia..iu.w4....is.aa..

f.liie.1ot,lf,y_pr.r,f..._t.. bu.e--.PliliJ.w1b.i.J,i.i1.1c.....i1111.1.ze.lru.e;:..At0.u.a,1,1t_-.i;.a1.1t..11:..i;e::.c.*r..i;e~di...---------:...

IIIIl '----------------------------------....1 cmJ

,. **as L.-

,__ _____ ~----------=so SYfflM.

.CAUSE.

CAUSE

COM~.

VALVE

[]El.

7 S

CCCE*

CODE SUBCCDE*

CCMIIONENT CODi SUICODE SUBCCDE

, c, c, e. l!..1 ts..J.@, x, x, x, x, x, x 1@ t£J ~

@Y 9

10 11 1:Z 13 18.

19 20 C

SIQU!NTIAL.-

OCCURRENCE

. REPORT t."::'\\ L!. R/AO EVENT YeAR' REPORT NO.

CODS*

TV,e

~

REPORT

, s I o 1

, o *1 6 1 3 r 1,...,

. 1 o 11 1 L!.J. 1=!

NUMBER 21

z:z:

. 23 2.&

  • 2&.

27

28.

29 30

n TAKEN ACTION ON PLANT METHOC lolQURS* 22 SUBMITTED FORM liUB. '

SUPPUER REVISION NO.

l1.J 3:

CCM,ONENT

  • MANUFACTURER*

ACTION l'IJTURE Ef'nCT.

SH~OWN

~

ATTACHMENT N,RD4.

,,IIME C:QM,,

W@)W@ W W 1* 0 I O I *0 I I L!J@-

l.!1@) LI@

33 34 3!i 3&

17

.&O 41

'2 43

  • .., T j O i 8 I 2 !@)

CAUSE CESCAIPTION ANC COARECTlv*e ACTIONS @

"4 47 [I((]_ I The cap screw failure has been attributed. to stress corrosiOn - cracking which initiated.

- 0::0:l I at surface pitting at the intersection of the cap sc;rew lead beaiiDi surface and the o::m t screw shank..

The Vascomax cap screws have been replaced. as part of the steam

!IIIl -L.*------------------------------------

.7 a 9 so*.

F~~~ *

"l'OWEPI*.

OTHER STATUS (§)

METHOD*OF CISCOYl:RY Cl~_ER'I' DESCRlmON.@

1DIJ.L!1@.. l*o IO IO J@I S/G.,lteplacement 7

8 9

10

,:z t3 4',

ACTIVITY CON'l'!NT IQ\\

w@**

41 41 ___

80

  • r.-r:,RELEAS!D OF REUASE AMOUNT OF AC'TlYIT.Y ~

~-uJ W@I N/A.

I a s 10 n

N/A P!FISONNEL eXl"OSURES Q

NUMBER TY,£ CESCJ'IIP'T\\ON ~

OJil I O ! 0 I O !@l!j@..__ ___

N;.;.:/_A;..._ _________________

~

a 9

12 1:1 so P!RSONNEI. INJURIES.

c::\\

NUMBER cesc1*11"10N'5

!Ili]J o! oj oj@ __

N

__ /_A ___________________.....

a. s 11 12 so t.QSS OF.OR'CAMAGE*TO FAA;IUTV ~

. TVPE.*. OESCRIP.T!ON

, * *~

IJEI_ u.I@Y..

N/A 7

i3 9

10 PUBLIClTV c.:'\\

ISSUED~ ces~.. 1"1QN ~

r:rw.. ULle,~ ________

N __ /_A ___________ ~ r,,,,,,,

7 S. 9 IQ.

611 H

so NRC USE ONLY I I I It_ ____.

80 ;

(804) 357-3184

!WON
:-.......... -----~---

J.,1.,.*,.

/.

J

  • .*...... __, _____ *------~~-- ----

UPDATED REPORT*-**

. PREVIOUS REPORT 12/02/80-"'- *--------*-** ---------

. ATTACHMENT 1 SURRY POWER STATION,. UNIT 1 DOCKET.NO:

50-280 REPORT NO:

80-063/0!X-1 EVENT DATE:

11-19-80 VASCOMAX CAP SCREW F~

.1. DESCRIPTION OF EVENT:

-* I> ----*-***-----*-----------*

During* disassembly-of "A" Steam* Generator* leveling Pads, in accordance with ETA 30017, a Vascomax cap screw was broken.The screw had been loosened-and was being turned out when it failed.

Preliminary investigation revealed that.

the. failure of the bolt 'had begun before removal..

  • ... '"'1'
2.

PROBABLE CONSEQUENCES' AND STATUS OF REDUNDAN'r -~QUIPMENT:

The other cap screws did not have any visible evidence of cracking.

and safety of the* public were not affected.

3.

CAUSE

The.health The failure of the cap screw has been attribut:ed-to~stress-corrosion cracking which initiated at surface-pitting at the intersection of* the cap screw. bearing surface and the-cap: screw shatik*~:. A stagn}lnt _space_ at __ *th:i,.s ----------'-*

location. coupled;/with a material susceptible

screw selected::for detailed examination indicates that stress corrosion cracking had initiated in this-bolt as we11.-*Tnis second bolt had been removed without breakage.

4..

Il1MEDIATE. CORRECTIVE ACTION:

~' o*A**-*-

- -*-*:. ---~.----- * '

The remainder.:of the broken bolt was. removed.

5.

SUBSEQUENT CORRECTIVE ACTION:

The failed bolt, as well as one bolt which. had been removed intact, were**

evaluated. by Lehigh University to determine _the.. made of fail~re (Refer to "Cause")__

6. "ACTION TAKEN TO PREVENT RECURRENCE:

TheVascomax cap screws have been replaced with cap screws of a superior material (ASTM A~574) as a part of the steam generator replacement project.

This. ~e.plaeement was already** accbmp-lished on Up.it _;l_L __..

7.
GENERIC lMPLICATIONS*:

The potential for failure, especially stress corrosion of this material was a major factor in.the scheduled bolt replacement.