05000280/FIN-2015003-03
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Failure to Verify Adequacy of Class 1E 125VDC Branch Circuit Breaker Design |
Description | The team identified a Green non-cited violation of 10 CFR Part 50, Appendix B, Criterion III, Design Control, for the licensees failure to verify or check the adequacy of design of the Class 1E 125 volt direct current (VDC) molded case circuit breakers (MCCBs). The licensee entered the issue into their CAP as CRs 559872 and 59875 and performed an immediate determination of operability, which determined the Class 1E 125VDC switchgear to be operable. The licensees failure to assure the quality levels of MCCBs through the specification of requirements known to promote high quality, such as requirements for design, for the de-rating of components, for manufacturing, quality control, inspection, calibration, and test, as specified by IEEE 279, Section 4.3, was a performance deficiency. The performance deficiency was determined to be more than minor because it was associated with the design control attribute of the Mitigating Systems Cornerstone and adversely affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the failure to adequately assess the electrical rating of electrical components could prevent the Class 1E 125VDC circuits from performing their safety function. The team determined the finding to be of very low safety significance (Green) because the finding was a deficiency affecting the design or qualification of a mitigating structure, system, or component, which maintained its operability or functionality. The team determined that no cross-cutting aspect was applicable because the finding was not indicative of current licensee performance. |
Site: | Surry |
---|---|
Report | IR 05000280/2015003 Section 4OA5 |
Date counted | Sep 30, 2015 (2015Q3) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | |
Inspectors (proximate) | A Masters C Jones E Stamm P Mckenna T Fanelli |
Violation of: | 10 CFR 50 Appendix B Criterion III, Design Control |
INPO aspect | |
' | |
Finding - Surry - IR 05000280/2015003 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Surry) @ 2015Q3
Self-Identified List (Surry)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||