Title | Failure to Have Adequate Analyses Supporting the Degraded Voltage Relay Setpoints |
Description | The team identified a Green non-cited violation of 10 CFR 50, Appendix B, Criterion III, Design Control, for the licensees failure to have adequate analyses that supported safety-related load operation during a design basis accident while supplied by offsite power. This was a performance deficiency. The licensee entered the issue into the corrective action program as Nuclear Condition Reports 601201 and 605969, and performed an evaluation that determined the capability of starting the safety-related motors at degraded voltage conditions, as well as the capability of the electrical loads during the degraded grid voltage relay (DGVR) time delay to ensure equipment function was preserved. The performance deficiency was more than minor because it affected the Mitigating Systems cornerstone attribute of Equipment Performance and adversely affected the cornerstone objective of ensuring reliability, availability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the licensee did not ensure the capability of safety related loads to respond to a design basis accident under degraded voltage conditions. Evaluations of the effects of starting motors at the DGVR voltage dropout setpoint and the equipment survivability during the DGVR time delay were not performed. The team determined the finding required a detailed risk analysis, because the finding was a deficiency affecting the design or qualification of a mitigating structure, system, or component, and the team assumed the performance deficiency represented a loss of operability or functionality of the equipment that could be lost during the DGVR time delay. This assumption was made to bound the risk of the finding, because the licensee was still investigating whether or not there would be a loss of function of any equipment during the DGVR time delay period as of the date of this inspection report issuance. The team assumed a recoverable loss of function of all 480V motor control centers and assumed a degraded voltage condition exposure time of one hour per year. The one hour per year assumption is conservative relative to actual plant data which indicated a degraded voltage condition exposure of 44 seconds over the past 3 operating years. The results of the detailed risk analysis indicated an increase in core damage frequency <1E-6/year, which is representative of a finding of very low safety significance (Green). No crosscutting aspect was assigned to this finding because the team determined that the cause of the finding was not indicative of current licensee performance due to the age of the degraded voltage evaluation. |
Site: | Robinson |
---|---|
Report | IR 05000261/2013007 Section 1R21 |
Date counted | Jun 30, 2013 (2013Q2) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.21 |
Inspectors (proximate) | A Alen G Nicely G Ottenberg H Campbell J Bartleman M Riley P Cooper R Nease S Walker |
Violation of: | 10 CFR 50 Appendix B Criterion III, Design Control |
INPO aspect | |
' | |
Finding - Robinson - IR 05000261/2013007 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Robinson) @ 2013Q2
Self-Identified List (Robinson)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||