| Reporting criterion: | 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2)(ix)(A) 10 CFR 50.73(a)(2)(iv)(A), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications |
| 2192007002R00 - NRC Website | |
text
AmerGen.
AmerGen Energy Company Oyster Creek US Route 9 South, P.O. Box 388 Forked River, NJ 08731-0388 www.exelonCOTP.COM An Exelon Company 10 CFR 50.73 September 18, 2007 RA-2007-025 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 - 0001 Oyster Creek Nuclear Generating Station Facility Operating License No. DPR-16 NRC Docket No. 50-219
Subject:
Licensee Event Report 2007-002-00, Intermediate Range Monitor (IRM) 16 Inoperable During Startup Enclosed is Licensee Event Report 2007-002-00, Intermediate Range Monitor (IRM) 16 Inoperable During Startup. This event did not affect the health and safety of the public or plant personnel. This event did not result in a safety system functional failure. There are no new regulatory commitments made in this LER submittal.
If any further information or assistance is needed, please contact Stevie Du Pont, Regulatory Assurance at 609-971-4033.
Sincerely,
,Rausch "
it President, Oyster Creek Nuclear Generating Station
Enclosure:
NRC Form 366, LER 2007-002-00 cc:
Administrator, USNRC Region I USNRC Project Manager, Oyster Creek USNRC Senior Resident Inspector, Oyster Creek File No. 07035
~29~
NRC FORM 366 U.S. NUCLEAR REGULATORY COMMISSION APPROVED BY OMB: NO. 3150-0104 EXPIRES: 06/30/2007 (6-2004)
, the NRC may not conduct or digits/characters for each block) sponsor, and a person is not required to respond to, the information collection.
- 3. PAGE Oystert Creek, Unit 1 05000 219 1
OF 4
- 4. TITLE Intermediate Range Monitor 16 Inoperable During'Startup
- 5. EVENT DATE
- 6. LER NUMBER
- 7. REPORT DATE
- 8. OTHER FACILITIES INVOLVED 7[SEQUENTIAL REV FACILITY NAME DOCKET NUMBER MONTH DAY YEAR YEAR NUMBER NO MONTH DAY YEAR 05000 j2007 FACILITYNAME DOCKET NUMBER j207 20 002...0 N05000
- 9. OPERATING MODE
- 11. THIS REPORT IS SUBMITTED PURSUANT TO THE REQUIREMENTS OF 10 CFR §: (Check all that apply) 20.2201(b) 20.2203(a)(3)(i) 50.73(a)(2)(i)(C) 50.73(a)(2)(vii)
- t
.u.
20.2201(d) 20.2203(a)(3)(ii) 50.73(a)(2)(ii)(A) 50.73(a)(2)(viii)(A) 20.2203(a)(1) 20.2203(a)(4) 50.73(a)(2)(ii)(B) 50.73(a)(2)(viii)(B) 20.2203(a)(2)(i) 50.36(c)(1)(i)(A) 50.73(a)(2)(iii) 50.73(a)(2)(ix)(A)
- 10. POWER LEVEL 20.2203(a)(2)(ii) 50.36(c)(1)(ii)(A) 50.73(a)(2)(iv)(A) 50.73(a)(2)(x) 000 20.2203(a)(2)(iii) 50.36(c)(2) 50.73(a)(2)(v)(A) 73.71 (a)(4)
,**." 000' 20.2203(a)(2)(iv) 50.46(a)(3)(ii) 50.73(a)(2)(v)(B) 73.71(a)(5) 20.2203(a)(2)(v) 50.73(a)(2)(i)(A) 50.73(a)(2)(v)(C)
OTHER 20.2203(a)(2)(vi)
X 50.73(a)(2)(i)(B) 50.73(a)(2)(v)(D)
Specify in Abstract below or in (If more space is required, use additional copies of (If more space is required, use additional copies of (If more space is required, use additional copies 0f NiC.. F-orm 36 A)
Corrective Action Completed.
Replaced IRM 16 detector and repaired IRM 17 instrumentation.
Corrective Action Planned.
Evaluate action plan to bring the Nuclear Instrumentation System back to Maintenance Rule (a)(2) status.
Evaluate the adequacy of IV and TDR testing at Oyster Creek to be able to identify this type of failure.
Provide training to engineers and instrument and control maintenance supervisors and managers to enhance testing and evaluation skills.
Previous Similar Occurrences There have been numerous previous detector failures in the industry including past failures at Oyster Creek Nuclear Generating Station.
Component Data.
Component:
Cause
System:
Component:
Manufacturer:
Model number:
IRM Nuclear Instrument Detector Failure Neutron Monitoring IRM Detector GE 129B3192