Finding | |
|---|---|
| Title | Failure to Conduct Representative Sampling of Stack Efffluents |
| Description | A Green, self-revealing NCV of TS 6.8.4 occurred due to Exelon\'s failure to maintain continuous, representative monitoring and sampling of plant stack gaseous effluents, as required by the Offsite Dose Calculation Manual. The cause was degradation of sample line integrity over the period March 2006 through March 2010. Exelon reported the issue, initiated compensatory monitoring, repaired the stack sample tubing, conducted bounding dose calculations, and entered this issue, including the evaluation of extent-of-condition, into the conective action program (lR 01053577). This finding is more than minor because the performance deficiency adversely impacted the Public Cornerstone objective of ensuring adequate protection of public health and safety in that effluent releases were not fully monitored in accordance with applicable requirements to ensure proper quantification and characterization of radioactive releases. This finding was assessed for significance using IMC 0609, Appendix D, and determined to be of very low safety significance because: Exelon was able to re-assess the radioactive effluent using alternative radiation monitoring instrumentation and programs, therefore Exelon had data by which to assess dose to a member of the public, determine the dose impact to the public, and conclude that the doses were less than the dose values in Appendix I to 10 CFR Part 50 and/or 10 CFR 20J301(e). This finding has a cross-cutting aspect in the area of Human Performance, Resources (H.2(c)) because procedures were not sufficiently robust for review of reasonableness and consistency of data from samples to support identification of the issue in a timely manner. |
| Site: | Oyster Creek |
|---|---|
| Report | IR 05000219/2010005 Section 4OA3 |
| Date counted | Dec 31, 2010 (2010Q4) |
| Type: | NCV: Green |
| cornerstone | Pr Safety |
| Identified by: | Self-revealing |
| Inspection Procedure: | IP 71153 |
| Inspectors (proximate) | M Modes J Kulp R Nimitz R Bellamy J Ambrosini C Newport |
| CCA | H.7, Documentation |
| INPO aspect | WP.3 |
| ' | |
Finding - Oyster Creek - IR 05000219/2010005 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Oyster Creek) @ 2010Q4
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||