ML20112G534

From kanterella
Jump to navigation Jump to search
Part 21 Rept Re Defective Rosemount Model 1153 Series B Transmitters.Potential Leak Path in Seal of Threads Between Sensor Module & Electronics Housing Exists.Transmitters Will Be Returned to Vendor
ML20112G534
Person / Time
Site: Clinton Constellation icon.png
Issue date: 03/22/1985
From: Hall D
ILLINOIS POWER CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
REF-PT21-85, REF-PT21-85-161-000 PT21-85-161, PT21-85-161-000, U-10256, NUDOCS 8504010150
Download: ML20112G534 (5)


Text

?

ornb

=u.

ILLIN0/8 POWER COMPANY CLINTON POWER STATION. P.O. BOX 678 CLINTON. ILLINOIS 61727 1A.120 '

U-10256

, March 22, 1985 Docket No. 50-461 .

Mr. James G. Keppler Regional. Administrator Region III U. S. Nuclear Regulatory Commission 799. Roosevelt Road Glen Ellyn, Illinois 60137

Subject:

10CFR Part 21 Defect in Rosemount Model 1153 B series transmitters (21-84-14)

Dear Mr. Keppler:

On November 5,1984, Illinois Power was advised by Baldwin

- Associates of ~a potential 10CFR21 defect in Rosemount Model 1153 Series B Transmitters. Based on an evaluation, Illinois Power is notifying the Commission of a 10CFR Part 21 reportable defect.

This report provides information as required by 10CFR Part 21.21 (3).

(1) D. P. Hall, Vice President of Illinois Power Company, Clinton Power Station, Clinton, IL 61727, by means of this report, hereby provideo the uritten notification of a 10CFR Part 21 defect to the NRC.

(ii) The basic components involved are Rosemount Model 1153 Series Transmitters manufactured during the period from January, 1984 to August, 1984.

(iii) The transmitters were manufactured by Rosemount Inc., 12001 West 78th Street, Eden Prairie, Minn.

55344 (Telephone (612)-941-5560).

(iv) A potential leak path in the seal of the threads between the sensor module and the electronics

,'" housing exists in these transmitters. This leak path could allow moisture from the environment to enter the electronics housing under abnormal conditions. Moisture in the electronics housing can cause transmitter failure. Failure of transmitters in safety related systems at a time of abnormal operation could result in a reduction p of performance in these systems.

i $ g l l

L. -

..______m....._ _ - . . - _ -

$7 .~

(v) Illinois Power was notified by Baldwin Associates on November 5, 1984 of a potential defect in the Rosemount Model 1153 Series B transmitters.

(vi) The equipment number and location of the transmitters-in use at, supplied for, or being supplied for Clinton Power Station are identified on the Attachment to this report.

.(vii) All-Rosemount'Model 1153. Series B transmitters at CPS that were manufactured between January and August of 1984 will.be returned to Rosemount's Eden Prairie facility for disassembly, cleaning

- and reassembly per Rosemount's new assembly procedure. .This action was begun on November.2, 1984 and is expected to continue through April 15, 1985. Baldwin Associates is responsible for those transmitters.not yet turned over to IP. IP Startup is responsible'for transmitters which have been turned over.

(viii) None Our evaluation of this reportable defect is available for your review at our offices. I trust that this letter provides sufficient,information for your review and analysis of the problem.

Si erel yours,

. P. Hall Vice President WE/skt (REC)

Attachment cc: NRC Resident Office Illinois Department of Nuclear Safety Director-Office of I&E USNRC, Washington, DC 20555 INPO Records Center

-Nl l_'. _ _ . 6

]

.. --j4 ,-

LT ' +~ t i

f: gg;*o -

a-ATTACHMENT dj u

{

~'

. . a m,y pe -

y;: e w;* y J+

4*

i; -

a

  • * +~ ,= .s

' # #~<'

l ': INTR LOCATION- SERVICE ~ Y I '

S

' (j

- :1E51-NO35A1 ;AL-124-737 ~1RCIC Storage Tank Level:

p. . . ,

h 4, iIC71-NO W .:CNT-73-755

~Drywell High Pressure:- Sq J1C71-N0508; .CNT-260-755 Drywell.HightPressure j

~

I 1E12-N058C.: ' RHR C Injection -Valve Press Perm :

-V-102-707' '[

Jc

?1521-N081A' :CNT-73-755 ' RPV Level.(WR)- [--

u IB21-N081B' CNT-260-755' RPV Level (WR).

1 . IB21-N081C CNT-148-755 RPV Level (WR)'

41B21-N081D- CNT-288-755 .RPV Level (WR)

, {

IB21-5091A1 CNT-73-755- RPV Level (WR) (LPCS, RCIC, ADS)~ 7l

- 11B21-50918 'CNT-260-755 RPV Level (WR)'(LPCS, RCIC, ADS) )

it IB21-N091E. CNT-73-755- RPV Level:(WR) (LPCS, RCIC, ADS) ' ' '

1821-N091T :CNT-260-755 RPV Level.(WR)

^

IB33-N014A'~ .CNT-208-755 RX RCRC Pump 1A Suction

.1833 1N014B' CNT-208-755 RX RCRC Pump 1A Suction

1B33-N014C~ CNT-157-755 RX RCRC Pump 1A Suction 1833-N014D. .CNT-157-755 RX RCRC Pump 1A Suction 2 ll 1B33-N024A ~ CNT-40-755 RX RCRC Pump 1B Suction

'e

, 1833-N024B CNT-40-755 RX RCRC Pump 1B Suction 1533-N024C CNT-297-755 , , RX RCRC Pump 1B Suction .

l 1B33-5024D CNT-297-755 RX RCRC Pump 1B Suction 1E22-5005 AH-104-712 HPCS Flow ,

e  :

1E31-N075A U-110-707 RWCU Line to Main Condenser 1E31-N075B- .V-102-707 RWCU Line to Main Condenser

. '1E31-N076A I CNT-73-755 RWCU Inlet Flow

, 1531-N076B 'CNT-40-755 RWCU Inlet Fluw

'1E31-5077A U-110-707 RWCU Line to HX Vessel V y 2

-Q

' ~

C.

.e

. i . . ,.

J e. - ATTACHMENT a- E 5

^

XNTR LOCATION SERVICE 2 -

.9 1E31-N077B V-102-707- RWCU Line to RX Vessel ,

g.

1E31-N089C' CNT-297-755 MS Line D Flow '. k

'3

-IB21-N068B CNT-260-755 RPV Press (ADS) Valve a

IB21-N068E CNT-73-755 RPV Press (ADS) Valve gf IB21-N068F CNT-260-755 RPV Press (ADS) Valve 1PT-O!063. AC-121-781 Drywell Pressure Div. 1 4 1PT-CM064 AC-105-781 Drywell Pressure Div. 2 I 1PT-CIO81 AC-121-781 Containment Prcss to Range <

'IPT-CM082. AE-103-781 Containment Press Lo Range IB21-N401E CNT-303-755 RPV Press ATWS CH E IB21-N401F CNT-270-755 RPV Press ATWS Cll F IB21-N076A N-112-774 MS Press At Stop Viv 3 1B21-5076D N-109-766 MS t'ress At Stop Viv 2 1B21-5078A CNT-73-755 RPV hessure 1B21-5078B CNT-260-755 RPV liigh Pressure 1B21-N078C CNT-148-755 RPV Pressure 1B21-N078D CNT-288-755 RPV Pressure IC41-N004 CNT-63-782 Standby Liquid Pump Disc Press 4

1E22-N051 AH-104-712 , , HPCS Pump Discharge Press .

1B21-N401A CNT-87-755 RPV Pressure ATWS CH A 1B21-N401B CNT-145-755 RPV Pressure ATWS CH B 1E32-N500 U-107-762 MSIV Sys Press IE32C001 SUCT 1E32-N501 X-107-781 MSIV Sys Press 1E32C002B&F SICT 1E31-N089D CNT-297-755 MS Line D Flow IPT-CM256 AC-121-781 Containment Press IPT-CM257 AC-103-781 Containment Press

n .- ; ,.

w :: ,y

~'-

ji . - -ATTACHMENT

. 4-

^ ,.-. ;

p XPfrR LOCATION SERVICE '

_ s; b

p 1C61-N509 'CNT-204-755 RPV Press i ,j 4

IPT-IA078 AC-1231762 ADS Inst Air HDR n,

IPT-IA079 AE-103-781 ADS Inst Air HDR .

-i 4

IPT-IA080 S-124-707 ADS Backup Air Bottles HDR .!!-

IPT-IA081 . W-105-707 ADS Backup Air Bottles HDR t- 3 1C61-N506' AH-116-723 Suppression PL WTR LVL  ;

IC61-N507 AH-1095-723 Suppression PL WTR LVL

.)' '

ILT-CM260A .AC-123-762 LSuppression PL WTR LVL (WR)

ILT-CM260B AC-123-762 Suppression PL WTR LVL (WR)

ILT-CM260C. .AC-123-750 Suppression PL.WTR LVL (WR) v IC61-N508 CNT-204-755 RPV Level (WR)

,IPT-CM264 'AC-123-781 RPV Press Low Range IPT-C 265 AH-109-755 RPV Press Low Range ILT-01260D AC-123-737 Suppression PL WTR LVL (WR)'

-1LT-CM260E AC-123-737. Suppression PL WTR LVL (WR)

ILT-CM260F 'AC-123-712 Suppression PL WTR LVL (WR)

I1LT-CH261A AD-103-755 Suppression PL VIR LVL (WR) 4 ILT-CM261B AD-103-755 Suppression PL WTR LVL (WR)

AD-103-755 Suppression PL WTR LVL (WR)

.1LT-CM261C ILT-CM261D AD-103-740 Suppression PL VIR LVL (WR)

ILT-CM261E AE-103-740 Suppression PL WTR LVL (WR)

ILT-CM261F AE-103-712 Suppression PL WTR LVL (WR)}