Reports Number of Tubes Plugged During Unit 1 Refueling Outage SL1-16,per TS 4.4.5.5.a
ML17241A481
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 10/01/1999
From: Stall J
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
L-99-218, NUDOCS 9910080125
Download: ML17241A481 (4)


Text

CArZaoar 1 REGULAT Y INFORMATION DISTRIBUTIO SYSTEM (RIDS)

ACCESSION NBR:9910080125 DOC.DATE: 99/10/01 NOTARIZED: NO DOCKET FACIL:50-335 St. Lucie Plant, Unit 1, Florida Power S Light Co. 05000335

~PA%.H "NAME; AUTHOR AFFILIATION STALL,J.A. Florida Power 8 Light Co.

RECIP.NAME RECIPIENT AFFILIATION Records Management Branch (Document Control Desk)

SUBJECT:

Submits number of tubes plugged during Unit 1 refueling outage SL1-16.

DTSTRTBUTTON CODE: A001D COPTER RECE1'UED:LTR I ENCL 0 S12E: r TITLE: OR Submittal: General Distribution NOTES:

RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL CLAYTON,B GLEAVES,W SC 0 INTERNAL: ACRS 1 FILE CENTER 01 NRR/DSSA/SPLB 1 R/DS SA/SMR(B NUDOCS-ABSTRACT 1 OGC/RP EXTERNAL: NOAC NRC PDR D

~III,gg g

NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR REMOVED FROM DISTRIBUTION LISTS ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD) ON EXTENSION 415-2083 TOTAL NUMBER OF. COPTER REQUTRED: LTTR 11 ENCL

Cr 4/P Florida Power 5 Light Company, 6351 S. Ocean Drive, Jensen Beach, FL 34957 October 1, 1999

@PL I 99-218 10 CFR 50.36 10 CFR 50.4 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Re: St. Lucie Unit 1 Docket No. 50-335 Special Report Steam Generator Tube Plu in Re ort This letter is being sent pursuant to St. Lucie Unit 1 Technical Specification 4.4.5.5.a. The following number of tubes were plugged during the Unit 1 refueling outage SL1-16.

Steam Generator 1A - 11 Steam Generator 1B - 0 Should you have any questions on this information, please contact us.

Very truly yours, J. A. Stall Vice President St. Lucie Plant JAS/GRM cc: Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, St. Lucie Plant Astir;an 9'Pi00801.25 99'i OOi F 0R AQQCX OSOOOSSS P PDR an FPL Group company

5

/

g 1 "(4 ~ 'M

)

f