ENS 54244
From kanterella
Jump to navigation
Jump to search
ENS Event | |
---|---|
18:16 Aug 28, 2019 | |
Title | Loss of High Presssure Core Spray |
Event Description | On Wednesday, August 28, 2019, at 1316 CDT, Grand Gulf Nuclear Station experienced a power loss to the Control Room High Pressure Core Spray (HPCS) Instrumentation Panel due to an internal inverter failure. The power loss caused the loss of the HPCS System (a single train system). The minimum flow valve (a Primary Containment Isolation Valve) for HPCS opened due to this power loss as well. This valve was manually closed in response to this, and the outboard isolation requirement for the associated penetration [which] is closed [for the] system remained intact throughout this event.
No other accident mitigation systems were affected by this event. The cause of this event is under investigation at this time. The NRC Resident Inspectors were notified. This Condition is an 8-hour reportable condition as an event or condition that could have prevented the fulfillment of a safety function, in accordance with 10 CFR 50.72(b)(3)(v)(D). |
Where | |
---|---|
Grand Gulf Mississippi (NRC Region 4) | |
Reporting | |
10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident | |
Time - Person (Reporting Time:+0.9 h0.0375 days <br />0.00536 weeks <br />0.00123 months <br />) | |
Opened: | Ronald Walters 19:10 Aug 28, 2019 |
NRC Officer: | Richard Smith |
Last Updated: | Aug 28, 2019 |
54244 - NRC Website | |
Unit 1 | |
---|---|
Reactor critical | Critical |
Scram | No |
Before | Power Operation (100 %) |
After | Power Operation (100 %) |
Retrieved from "https://kanterella.com/w/index.php?title=ENS_54244&oldid=2508167"