05000373/FIN-2018002-04
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Minor Violation - Follow-up of Events and Notices of Enforcement Discretion |
Description | Minor Violation: For S/RV 2B21F013L, serial number N63790050012 (hereafter referred to as S/RV 12), the licensee completed a work group evaluation as documented in AR 03975216ACIT No. 3 to investigate the cause for two S/RVs that failed a set pressure lift test out of specification low. For ACIT No. 3, the licensee staff incorporated a vendor letter that documented the results of the S/RV vendors review of the S/RV 12 condition and which recorded an out of tolerance spring condition. It stated that The spring was measured and rate tested. The free height was found to be below the minimum original equipment manufacturer specified tolerance. The licensees vendor subsequently replaced the nonconforming spring with a new spring. In prior vendor correspondence with the licensee (reference E-mail dated June 24, 2015), the vendor stated that Typically we contribute a low as-found lift to an out-of-tolerance spring rate or free height dimension. Therefore, the nonconforming spring free height dimension may have caused the low as-found lift setpoint failure for this valve and as such was relevant (e.g. material) to the determination of a failure cause that was reported in LER 05000374/201700400 and 01. However, the licensee failed to identify this during their cause investigation and erroneously reported in LER 05000374/201700400 and 01 that The vendor reported for both valves that all the spring tolerances were within the acceptance limits. The licensee documented this violation in AR 04134591, Potential Minor Violation for Unit 2 LER 20170401. The licensee also submitted a revision to the LER as LER 05000374/201700402
Screening: The significance determination process does not specifically consider the regulatory process impact in its assessment of licensee performance. Therefore, it is necessary to address this violation which could impede the NRCs ability to regulate using traditional enforcement to adequately deter non-compliance. The inspectors determined that this issue was a Severity Level IV violation based on Example 6.9.d.10 in the NRC Enforcement Policy which states, A failure to identify all applicable reporting codes on a Licensee Event Report that may impact the completeness or accuracy of other information (e.g. performance indicator data) submitted to the NRC. In accordance with the Section 2.2.1.c of the NRC enforcement policy, the severity level of a violation involving the failure to make a required report to the NRC will depend on the significance of and the circumstances surrounding the matter that should have been reported. The NRC had not relied on information in this LER report to make a regulatory decision, and the inspector answered no to each of the more than minor screening questions in Appendix B of IMC 0612 for the issue of concern. Therefore, the NRC determined this was a minor violation because it was associated with a minor performance deficiency. Violation: Failure to comply with 10 CFR 50.9 Completeness and accuracy of information and accurately report the nonconforming S/RV 12 spring tolerance in LER 05000374/201700400 and 01 to the NRC constitutes a minor violation that is not subject to enforcement action in accordance with the NRCs Enforcement Policy. |
Site: | LaSalle |
---|---|
Report | IR 05000373/2018002 Section 4OA3 |
Date counted | Jun 30, 2018 (2018Q2) |
Type: | Violation: Severity level Minor |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71153 |
Inspectors (proximate) | W Schaup J Havertape M Holmberg A Nguyen R Ng G Roach B Dickson |
Violation of: | 10 CFR 50.9 |
INPO aspect | |
' | |
Finding - LaSalle - IR 05000373/2018002 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (LaSalle) @ 2018Q2
Self-Identified List (LaSalle)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||