| Title | Failure to have Adequate Justification for Extending the life of Lubricant used in EQ Motor Bearings |
| Description | The inspectors identified a finding of very-low safety significance and an associated NCV of 10 CFR Part 50.49, Paragraph (j), Environmental Qualification of Electrical Equipment Important to Safety for Nuclear Power Plants, for the licensees failure to have adequate justification for extending the service-life for grease used in the bearing for EQ motors installed in harsh environment. Specifically, the licensee extended the bearing grease qualified service life for several EQ motors installed in Zone H4A, H6 and H5A from 31.5, 20.5 and 19.5 years respectively to 60 years based on incorrect assumptions. The justification for 60 years extension incorrectly assumed that the calculated service-life was based on continuous operation of the motor. The licensee captured the inspectors concern into their CAP as AR 04030538. The performance deficiency was determined to be more-than-minor because it was associated with the Mitigating Systems cornerstone attribute of design control and affected the cornerstone objective of ensuring the availability, reliability, and capability of mitigating systems to respond to initiating events to prevent undesirable consequences. The finding screened as of very-low safety significance (Green) because it did not result in the loss of operability or functionality of mitigating systems. Specifically, as an immediate corrective action, the licensee performed a preliminary evaluation that concluded that the grease remained qualified based on test data which showed that the grease consistency remained within acceptable range during the thermal age test. The finding did not have a cross-cutting aspect associated with it because it was not representative of current performance. |
| Site: | LaSalle |
|---|---|
| Report | IR 05000373/2017008 Section 1R21 |
| Date counted | Sep 30, 2017 (2017Q3) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.21 |
| Inspectors (proximate) | G Hausman A Dahbur J Gilliam |
| Violation of: | 10 CFR 50.49 |
| INPO aspect | |
| ' | |
Finding - LaSalle - IR 05000373/2017008 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (LaSalle) @ 2017Q3
Self-Identified List (LaSalle)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||