05000220/FIN-2015009-02
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Inadequate Maintenance Rule Monitoring of Unit 1 600 VAC Breaker Super System |
Description | The inspectors identified a Green NCV of 10 CFR 50.65, Requirements for Monitoring the Effectiveness of Maintenance at Nuclear Power Plants, under section (a)(1) and (a)(2) for failing to properly monitor the 600 volt alternating current (VAC) system at Unit 1 in accordance with established maintenance rule reliability criteria to assure that breakers were capable of performing their intended function. Specifically, the inspectors identified four events that were not evaluated against the established (a)(2) reliability criteria. This resulted in a failure to evaluate the 600 VAC system for potential corrective actions in accordance with (a)(1) and did not ensure effective control through preventative maintenance to show the system was capable of performing its intended function in accordance with (a)(2). Exelons immediate corrective actions included evaluations of the failures and planning for a maintenance rule expert panel for consideration of placing the system into (a)(1) where corrective actions could be developed to return the system to (a)(2) monitoring. Exelon also noted that IR 2416790 documented the challenge associated with overcurrent trip device drift and subsequent pump failures. This IR was open at the time of the inspection with actions to determine if a replacement is possible and to present any potential options to Plant Health Committee in October 2015. This performance deficiency is more than minor because it is associated with the equipment performance attribute of the Mitigating Systems cornerstone and affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the overcurrent trip devices associated with Unit 1 600 VAC General Electric (GE)-AK breakers were unreliable and resulted in the trip of five safety-related pumps between April 2013 and February 2014. Only one of the five functions was evaluated by Exelon. This impacted the ability of these pumps to be able to perform their function to provide cooling to their respective systems. In accordance with IMC 0609.04, Initial Characterization of Findings, and IMC 0609, Appendix A, The Significance Determination Process for Findings At-Power, issued June 19, 2012, the inspectors determined this finding was of very low safety significance (Green) because this finding did not represent an actual loss of system safety function, did not represent an actual loss of function of at least a single train for greater than its TS allowed outage time, and did not represent an actual loss of function of one or more non-TS trains of equipment designated as high safety-significant in accordance with Exelons maintenance rule program for greater than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. This finding has a cross-cutting aspect in the area of Problem Identification and Resolution, Evaluation, because Exelon failed to thoroughly evaluate the failures against the monitoring criteria specified for the Unit 1 600 VAC breaker super system. Specifically, between April 2013 and February 2014, four breaker failures were identified by the inspectors that were not evaluated against the Unit 1 600 VAC breaker super system, which prevented compliance with 10 CFR 50.65 (a)(1) to ensure corrective actions are established to return the system to (a)(2) monitoring. |
Site: | Nine Mile Point |
---|---|
Report | IR 05000220/2015009 Section 4OA2 |
Date counted | Sep 30, 2015 (2015Q3) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71152 |
Inspectors (proximate) | A Siwy B Pinson D Schroeder E Dipaolo E Miller |
Violation of: | 10 CFR 50.65(a)(1) 10 CFR 50.65 Technical Specification |
CCA | P.2, Evaluation |
INPO aspect | PI.2 |
' | |
Finding - Nine Mile Point - IR 05000220/2015009 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Nine Mile Point) @ 2015Q3
Self-Identified List (Nine Mile Point)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||