Pages that link to "05000293/LER-1982-028, Forwards LER 82-028/03L-0"
Jump to navigation
Jump to search
The following pages link to 05000293/LER-1982-028, Forwards LER 82-028/03L-0:
Displayed 50 items.
- 05000293/LER-1982-018, Forwards LER 82-018/03L-0 (← links)
- 05000293/LER-1982-019, Forwards LER 82-019/03L-0 (← links)
- 05000293/LER-1982-017, Forwards LER 82-017/03L-0 (← links)
- 05000293/LER-1982-016, Forwards LER 82-016/03L-0 (← links)
- 05000293/LER-1982-015, Forwards LER 82-015/03L-0 (← links)
- 05000293/LER-1982-009, Forwards LER 82-009/03L-0 (← links)
- 05000293/LER-1982-037, Forwards LER 82-037/03L-0 (← links)
- 05000293/LER-1982-029, Forwards LER 82-029/03L-0 (← links)
- 05000293/LER-1982-022, Forwards LER 82-022/03L-0 (← links)
- ML20065A250 (redirect page) (← links)
- 05000293/LER-1982-028 (redirect page) (← links)
- 05000293/LER-1982-030, Forwards LER 82-030/03L-0 (← links)
- 05000293/LER-1982-026, Forwards LER 82-026/01T-0 (← links)
- 05000293/LER-1982-024, Forwards LER 82-024/01T-0 (← links)
- 05000293/LER-1982-025, Forwards LER 82-025/01T-0 (← links)
- 05000293/LER-1982-023, Forwards LER 82-023/01T-0 (← links)
- 05000293/LER-1982-056, Forwards LER 82-056/01T-0 (← links)
- 05000293/LER-1982-035, Forwards LER 82-035/03L-0 (← links)
- 05000293/LER-1982-036, Forwards LER 82-036/03L-0 (← links)
- 05000293/LER-1982-027, Forwards LER 82-027/03L-0 (← links)
- 05000293/LER-1982-021, Forwards LER 82-021/03L-0 (← links)
- 05000293/LER-1982-057, Forwards LER 82-057/03L-0 (← links)
- 05000293/LER-1982-053, Forwards LER 82-053/03L-0 (← links)
- 05000293/LER-1982-048, Forwards LER 82-048/03L-0 (← links)
- 05000293/LER-1982-038, Forwards LER 82-038/03L-0 (← links)
- 05000293/LER-1982-031, Forwards LER 82-031/03L-0 (← links)
- 05000293/LER-1982-033, Forwards LER 82-033/03L-0 (← links)
- 05000293/LER-1982-055, Forwards LER 82-055/03L-0 (← links)
- 05000293/LER-1982-049, Telecopy LER 82-049/01X-0:on 821102,safety Valve a Found Set W/Nitrogen at Steam Relief Setting.Caused by Personnel Error.Properly Tested Spare Valve Installed.Personnel Admonished to Read & Follow Procedures Exactly (← links)
- 05000293/LER-1982-051, Forwards LER 82-051/03L-0 (← links)
- 05000293/LER-1982-041, Forwards LER 82-041/03L-0 (← links)
- 05000293/LER-1982-044, Forwards LER 82-044/03L-0 (← links)
- 05000293/LER-1982-042, Forwards LER 82-042/03L-0 (← links)
- 05000293/LER-1982-043, Forwards LER 82-043/03L-0 (← links)
- 05000293/LER-1982-008, Forwards LER 82-008/01T-0 (← links)
- 05000293/LER-1982-004, Telecopy Message of LER 82-004/01X-0:on 820222,primary Containment Isolation Valve Flanges Discovered W/Provision for Type B Llr Testing.Flanges Previously Type a Tested. Flanges Added to Llr Test Program (← links)
- 05000293/LER-1982-003, Forwards Updated LER 82-003/99X-2 (← links)
- 05000293/LER-1982-013, Forwards Updated LER 82-013/03X-1 (← links)
- 05000293/LER-1982-020, Forwards LER 82-020/03L-0 (← links)
- 05000293/LER-1982-006-03, /03X-1:on 820309,three of Four Cap Screws That Attach Main Disk Flange to Main Disk Found Broken.Caused by Overload Conditions Resulting from Erratic Valve Operation. Procedure Developed to Adjust Turbine Valve (← links)
- 05000293/LER-1982-012-03, /03L-0:on 820430,during steady-state Operation, Diesel Generator a Did Not Respond to Start Signal During Surveillance Test.Caused by Defective Pak Unit.Circuit Repaired (← links)
- 05000293/LER-1982-008-01, /01T-0:on 820331,while Conducting Surveillance Test 8.I.13,during Startup,Hpci Injection Valve MO-2301-8 Did Not Fully Open.Caused by Missing Jumper Wire Intended to Bypass Motor Operator Torque Switch (← links)
- 05000293/LER-1982-057-03, /03L-0:on 821213,during Routine Startup from Outage,Outboard MSIV AO 203-2C Did Not Close within Tech Spec Limit.Caused by Malfunctioning four-way Control Valve. Valve Replaced.Timing Dash Pot Adjusted (← links)
- 05000293/LER-1982-054-03, /03L-0:on 821111,RPS Relay 5AK-3G Did Not Respond When D MSIV Inboard Valve Tested for 10% Closure.Caused by Failed Limit Switch.Fuse Removed.Repairs to Limit Switch Added to Next Drywell Entry Procedures (← links)
- 05000293/LER-1982-053-03, /03L-0:on 821110,ground Fault Alarm Observed on 125-volt Dc Battery Circuit & Traced to Limit Switch Circuitry for MOV2301-3.Caused by Valve Packing Steam Leakage.Packing Tightened for short-term Fix (← links)
- 05000293/LER-1982-048-03, /03L-0:on 821006,during Qad Audit,Fire Door 153 Found Closed W/Latch Mechanism Depressed W/Tape.Caused by Personnel Error.Special Meeting Conducted on 821029 Re QA Requirements & QA Significant Deficiency Rept Issued (← links)
- 05000293/LER-1982-038-03, /03L-0:on 820817,while Starting Up from Cold Shutdown,Reactor Core Isolation Cooling Steam Line High Differential Pressure Alarm Received.Caused by Air in Sensing Lines to Differential Pressure Switches (← links)
- 05000293/LER-1982-032-03, /03L-0:on 820818,while Conducting Plant Startup from Cold Shutdown,Oxygen Concentration & Drywell to Torus Differential Pressure Not Established in 24-h as Required by Tech Spec.Caused by Failure of Gasket on Nitrogen Vapori (← links)
- 05000293/LER-1982-031-03, /03L-0:on 820818,reactor Water Conductivity Observed Above Tech Spec Limit.On 820820,recirculation Pump Speed & Drive Flow Relationship Mismatched.Caused by High Conductivity Due to Resin Intrusion (← links)
- 05000293/LER-1982-052-03, /03L-0:on 821028,recirculation Pump a MG Set Inadvertently Tripped While Troubleshooting Ground Indication for 125-volt Dc Circuit.Caused by Inadequate Info Available to Troubleshooters.Info Upgraded (← links)