Category:Inspection Report
MONTHYEARIR 07200015/20244012024-10-30030 October 2024 NRC Independent Spent Fuel Storage Installation Security Inspection Report No. 07200015/2024401 IR 05000219/20240022024-09-0505 September 2024 – NRC Inspection Report 05000219/2024002 and 07200015/2024001 IR 05000219/20240012024-05-14014 May 2024 Decommissioning Intl, LLC Oyster Creek Nuclear Generating Station - NRC Inspection Report No. 05000219/2024001 ML24046A1242024-02-29029 February 2024 – NRC Inspection Report 05000219/2023003 IR 05000219/20230022023-11-0909 November 2023 EA-23-076 Oyster Creek Nuclear Generating Station - Notice of Violation and Proposed Imposition of Civil Penalty - $43,750 - NRC Inspection Report No. 05000219/2023002 ML23214A2472023-08-22022 August 2023 – NRC Inspection Report 05000219/2023002 IR 05000219/20230012023-05-31031 May 2023 – NRC Inspection Report No. 05000219/2023001 IR 07200015/20234012023-05-16016 May 2023 – NRC Independent Spent Fuel Storage Installation Security Inspection Report 07200015/2023401 IR 05000219/20220022023-02-0909 February 2023 NRC Inspection Report No. 05000219/2022002 IR 07200015/20224012022-12-0606 December 2022 NRC Independent Spent Fuel Storage Installation Security Inspection Report 07200015/2022401 (Letter & Enclosure 1) IR 05000219/20220012022-08-11011 August 2022 NRC Inspection Report 05000219/2022001 IR 05000219/20210042022-01-26026 January 2022 NRC Inspection Report No. 05000219/2021004 IR 05000219/20214022022-01-26026 January 2022 EA-21-041: Confirmatory Order Related to Oyster Greek Nuclear Generating Station - NRC Investigation Report I-2020-007; NRC Inspection Report Nos. 05000219/2021402 & 07200015/2021401 IR 05000219/20214032021-12-21021 December 2021 EA-21-093 Notice of Violation and Proposed Imposition of Civil Penalty - $150,000, Inspection Report No. 05000219/2021403 IR 05000219/20210032021-11-16016 November 2021 NRC Inspection Report No. 05000219/2021003 IR 05000219/20214042021-08-26026 August 2021 NRC Independent Spent Fuel Storage Security Inspection Report No. 07200015/2021402 and Security Decommissioning Inspection Report 05000219/2021404 - (Public) ML21202A2312021-07-28028 July 2021 Discretionary Security Decommissioning Inspection Report No. 05000219/2021403 - Public Version IR 05000219/20210022021-07-27027 July 2021 NRC Inspection Report No. 05000219/2021002 and Independent Spent Fuel Storage Installation Report 07200015/2021002 IR 05000219/20210012021-05-18018 May 2021 NRC Inspection Report No. 05000219/2021001 and Independent Spent Fuel Storage Installation Report 07200015/2021001, Holtec Decommissioning International, LLC, Oyster Creek Nuclear Generating Station IR 05000219/20204022020-12-14014 December 2020 Security Decommissioning Inspection Report 05000219/2020402 (Public - No Findings) IR 05000219/20200032020-10-21021 October 2020 NRC Inspection Report No. 05000219/2020003, Holtec Decommissioning International, LLC, Oyster Creek Nuclear Generating Station, Forked River, New Jersey IR 05000219/20204012020-07-27027 July 2020 Security Baseline Inspection Report 05000219/2020401 IR 05000219/20200022020-07-20020 July 2020 NRC Inspection Report No. 05000219/2020002, Holtec Decommissioning International, LLC, Oyster Creek Nuclear Generating Station, Forked River, New Jersey IR 05000219/20200012020-04-20020 April 2020 Forked River, New Jersey, NRC Inspection Report 05000219/2020001 IR 05000219/20190042020-01-0606 January 2020 NRC Inspection Report 05000219/2019004, Holtec Decommissioning International, LLC, Oyster Creek Nuclear Generating Station, Forked River, New Jersey IR 05000219/20190032019-10-28028 October 2019 NRC Inspection Report No. 05000219/2019003, Holtec Decommissioning International, LLC, Oyster Creek Nuclear Generating Station, Forked River, New Jersey IR 05000219/20190022019-07-24024 July 2019 NRC Inspection Report 05000219/2019002 IR 05000219/20190012019-04-15015 April 2019 NRC Inspection Report No. 05000219/2019001, Oyster Creek Nuclear Generating Station IR 05000219/20194012019-03-25025 March 2019 NRC Inspection Report No. 05000219/2019401 (Public) IR 05000219/20180122019-02-19019 February 2019 NRC Inspection Report No. 05000219/2018012, Oyster Creek Nuclear Generating Station IR 05000219/20180032018-11-0808 November 2018 Integrated Inspection Report 05000219/2018003 IR 05000219/20180022018-08-0202 August 2018 Integrated Inspection Report 05000219/2018002 and Independent Spent Fuel Storage Installation Report 0700015/2018001 IR 05000219/20184102018-06-18018 June 2018 Security Inspection Report 05000219-2018410 (Cover Letter) IR 05000219/20180012018-05-0808 May 2018 Integrated Inspection Report 05000219-2018001 and Exercise of Enforcement Discretion IR 05000219/20180102018-02-28028 February 2018 Design Bases Assurance Inspection (Programs) Report 05000219/2018010 IR 05000219/20170062018-02-28028 February 2018 Annual Assessment Letter for Oyster Creek Nuclear Generating Station (Reports 05000219/2017006 05000219/2017402 and 05000219/2017501) IR 05000219/20170042018-01-24024 January 2018 NRC Integrated Inspection Report 05000219/2017004 IR 05000219/20170092017-11-30030 November 2017 Temporary Instruction 2515-191 Inspection Report 05000219/2017009 IR 05000219/20174052017-10-25025 October 2017 Problem Identification and Resolution Sample Security Inspection Report 05000219/2017405 (Cover Letter) IR 05000219/20170032017-10-17017 October 2017 Integrated Inspection Report 05000219/2017003 IR 05000219/20170082017-10-17017 October 2017 Supplemental Inspection Report 05000219/2017008 and Assessment Follow-Up Letter IR 05000219/20175022017-10-16016 October 2017 Evaluated Emergency Preparedness Exercise Inspection Report 05000219-2017502 IR 05000219/20170052017-08-28028 August 2017 Updated Inspection Plan Report 05000219 2017005 with Report 22 IR 05000219/20174042017-08-15015 August 2017 Problem Identification and Resolution Cyber Security Inspection Report 05000219/2017404 (Cover Letter) IR 05000219/20170022017-08-0303 August 2017 Integrated Inspection Report 05000219/2017002 IR 05000219/20174032017-05-0909 May 2017 Security Inspection Report 05000219-2017403 (Cover Letter) IR 05000219/20170012017-05-0808 May 2017 Integrated Inspection Report 05000219/2017001 IR 05000219/20170072017-05-0101 May 2017 IR 05000219/20160042017-04-13013 April 2017 Final Significance Determination for a White Finding with Assessment Follow-up and Notice of Violation - Inspection Report 05000219/2016004 IR 05000219/20160062017-03-0101 March 2017 Annual Assessment Letter for Oyster Creek Nuclear Generating Station (Report 05000219/2016006) with Report 22 2024-09-05
[Table view] |
Text
Oyster Creek Outage Inspection License Renewal Commitments
-IP 71003 Drywell Shell Thickness Verifications Lower Drywell Shell Internal UT (at Sand Bed Region elevations) 19 Locations inside drywell [IS-328227-004, 3.2.2]7x7 arrays over a 6"x6" area, and 1x7 arrays, on 1" increments 29 Oct Day Shift, R2096031 [date confirmed by NDE]Commitment 27, Item (1 & 21)Lower Drywell Shell External UT (in Sand Bed Bays)106 UT readings, in the 10 bays (2-shift, 24-hr activities)
[IS-328227-004, 3.2.3]Access through 20" manway (tunnel), Commitment 27, Item (9, 14, & 21)Bay 1 30 Oct [critical bay,.based on previous inspection]
Bay 3 30 Oct Bay 5 27 Oct Bay 7 29 Oct Bay 9 28 Oct Bay 11, 28 Oct [critical bay, based on previous inspection]
Bay 13 28 Oct [critical bay, based on previous inspection]
Bay 15 29 Oct Bay 17 3 Nov Bay 19 30 Oct Upper Drywell Shell UT at Elev 71' (knuckle region)Transition from 2.625" plate to 0.640" plate [IS-328227-004, 3.2.8]4 locations using a dynamic scan of a 6"x6" area 1 Nov 1700, R2096037 Commitment 27, Item (11)Lower Drywell Shell UT at Elev 23' (bottom to middle spherical plates)Transition from 0.770" plate to 1.154" plate [IS-328227-004, 3.2.7]4 locations using a dynamic scan of a 6"x6" area Does NOT appear to be scoped into outage[29 Oct 0600, C2017059 (one-time inspection of 4 butt welds)]Commitment 27, Item (10)Upper Drywell Shell UT at Various Elevations 9 locations using a 7x7 array, at elev. 50', 51', 60', and 87' [IS-328227-004, 3.2.1]Commitment 27, Item (7)Drywell Floor Inspection Access Trenches UT & VT in Bay 5 & Bay 17 Trenches [IS-328227-004, 3.2.6]Remove & reinstall lower 6" of grout at bottom of Bay 5 trench Inspect caulk sealant (trench edge where concrete meets shell)Verify no water accumulation 29 Oct 2100, R2117387 Commitment 27, Item (5, 16, & 20)
Oyster Creek Outage Inspection License Renewal Commitments
-IP 71003 Drywell Shell Leakage Verifications Cavity Strippable Coating prior to flood-up 27 Oct 1500, R2098683 Commitment 27, Item (2)Rx Cavity Concrete Trough Drain Camera Inspection of Rx cavity drain line for blockage 29 Oct 0300, R2095857 Commitment 27, Item (13)[how many drain lines?]Rx Cavity Seal Leakage Trough Drains Daily leakage check R2102695 Commitment 27, Item (3)[how many drain lines?][configuration description?]
[any leakage detection instrumentation?]
Sand Bed Region Drains (5 drain lines)Daily leakage check R2102695 Commitment 27, Item (3)Moisture Barrier Seal between'Sand Bed Region Concrete and Embedded Drywell Shell Inspect seal at junction between concrete and shell [IS-328227-004, 3.2.4.1.4]
?? Schedule Date Commitment 27, Item (3, 12, & 21)Moisture Barrier between Drywell Shell and Concrete Floor Curb inside Drywell Inspect moisture barrier between curb and shell 30 Oct 0600, R2097321 Commitment 27, Item (17)Drywell Shell Coating Verifications Drywell Interior Service Level I Coating Inspect shell coating inside drywell 29 Oct 0500, R2096685 Commitment 33, Item (1)
Oyster Creek Outage Inspection License Renewal Commitments
-IP 71003 Drywell Exterior Service Level II Coating in Sand Bed Bays VT epoxy coating in each bay (2-shift, 24-hr activities)
[IS-328227-004, 3.2.4]Commitment 27, Item (4 & 21)Commitment 33 Bay 1 4 Nov Bay 3 28 Oct Bay 5 2 Nov Bay 7 29 Oct Bay 9 28 Oct Bay 11 28 Oct Bay 13 28 Oct Bay 15 29 Oct Bay 17 2 Nov Bay 19 28 Oct Electrical Cable Inspections Feeder Cable to Auxiliary Transformer (Bank 4)Inaccessible Medium Voltage Cable Perform power factor test of 4 kV transformer feeder cable 30 Oct 1000, R2026131 Commitment 36 Feeder Cable to Startup Transformer (Bank 6)Inaccessible Medium Voltage Cable Power factor test of 4 kV transformer feeder cable 2 Nov 0600, R2033700 Commitment 36 Feeder Cable to P-37-1 Inaccessible Medium Voltage Cable Hi-Pot feeder cable 29 Oct 0500, R2054006 Commitment 36 Feeder Cable to P-37-5 Inaccessible Medium Voltage Cable Hi-Pot feeder cable?? Schedule Date, R2059713 Commitment 36 Cable Inspection in Trunion Room Visually inspect a representative sample of accessible cables and connections located in adverse localized environments, for indications of accelerated insulation aging 26 Oct 0400, R2122597 Commitment 34 Oyster Creek Outage Inspection License Renewal Commitments
-IP 71003 Cable Inspection in Drywell Visually inspect a representative sample of accessible cables and connections located in adverse localized environments, for indications of accelerated insulation aging 29 Oct 0500, R2122597 Commitment 34 Non-drywell ISI & NDE Inspections Isolation Condenser One-time Inspection of two stainless steel pipe sections in stagnant or low flow area in the Isolation Condenser System, to verify no stress corrosion cracking.A2184119 (AR/Library)
?? Schedule Date Commitment 24, Item (8)Isolation Condenser One-time Inspection UT of "B" Isolation Condenser shell below the waterline, to verify no pitting corrosion and confirm effectiveness of Water Chemistry Program.?? Schedule Date, still in pre-planning, NOT scoped into outage Commitment 24, Item (2)Open Cycle Cooling & Buried PipeInspections ESW Expansion Joint Periodic inspection 27 Oct 1400, R2081668 Commitment xx ??ESW Buried Piping Replace previously un-replaced buried ESW piping New pipe already installed, needs to be connected in-place of existing old pipe?? Schedule Date for new piping tie-in Commitment 63 ESW Intake Structure Periodic inspection of components submerged in salt water Structures Monitoring Program, inspect ESW/SW piping & components located under the Deck?? Schedule Date, NOT planned or scoped into outage (R2120584)
Commitment 31 Item (7)Commitment 32 Item (2)