| | | Reporting criterion |
|---|
| 05000325/LER-1981-001, Forwards LER 81-001/01T-0 | Forwards LER 81-001/01T-0 | |
| 05000325/LER-1981-001-01, /01T-0:on 810103,feed Pump Tripped on High Vessel Level Due to safety-relief Valve B21-F013G,Model 67F,lift. Caused by High Second Stage & Pilot Leakage in Valve.Pilot Valve Temporarily Replaced Until Next Scheduled Outage | /01T-0:on 810103,feed Pump Tripped on High Vessel Level Due to safety-relief Valve B21-F013G,Model 67F,lift. Caused by High Second Stage & Pilot Leakage in Valve.Pilot Valve Temporarily Replaced Until Next Scheduled Outage | |
| 05000324/LER-1981-001, Forwards LER 81-001/03L-0 | Forwards LER 81-001/03L-0 | |
| 05000324/LER-1981-001-03, /03L-0:on 810129,during Surveillance Testing, HPCI Sys Initiation Reactor Level Switch Actuated at Simulated Level Above Tech Spec.Caused by Components Slipping Due to Loose Set Screws on Actuator Pointers | /03L-0:on 810129,during Surveillance Testing, HPCI Sys Initiation Reactor Level Switch Actuated at Simulated Level Above Tech Spec.Caused by Components Slipping Due to Loose Set Screws on Actuator Pointers | |
| 05000325/LER-1981-002-03, /03L-0:on 810114 & 0212,reactor Protection Sys Logic relays,C71-K3D & K3E,did Not de-energize When MSIV 1-B21-F028B Was Closed.Caused by Sticking Valve Position Limit Switch Actuator Arm Cam.Switch Replaced | /03L-0:on 810114 & 0212,reactor Protection Sys Logic relays,C71-K3D & K3E,did Not de-energize When MSIV 1-B21-F028B Was Closed.Caused by Sticking Valve Position Limit Switch Actuator Arm Cam.Switch Replaced | |
| 05000325/LER-1981-002, Forwards LER 81-002/03L-0 | Forwards LER 81-002/03L-0 | |
| 05000324/LER-1981-002-03, /03L-0:on 810104,vacuum Breaker X-18A Had Dual open-close Position Indication While in Open Position. Probably Caused by Problem W/Vacuum Breaker Position Limit Switches.Problem Will Be Resolved During Next Outage | /03L-0:on 810104,vacuum Breaker X-18A Had Dual open-close Position Indication While in Open Position. Probably Caused by Problem W/Vacuum Breaker Position Limit Switches.Problem Will Be Resolved During Next Outage | |
| 05000324/LER-1981-002, Forwards LER 81-002/03L-0 | Forwards LER 81-002/03L-0 | |
| 05000324/LER-1981-003-03, /03L-0:on 810108,suppression Pool Level Exceeded Specs.Caused by Valve Operator Torque Switch Out of Adjustment Allowing Leakage Into Suppression Pool.Switch Repaired | /03L-0:on 810108,suppression Pool Level Exceeded Specs.Caused by Valve Operator Torque Switch Out of Adjustment Allowing Leakage Into Suppression Pool.Switch Repaired | |
| 05000324/LER-1981-003, Forwards LER 81-003/03L-0 | Forwards LER 81-003/03L-0 | |
| 05000325/LER-1981-003-03, /03L-0:control Rod 26-35 on 810103,18-51 on 810113,38-31 & 22-15 on 810114 Showed Inaccurate Position Indications.Caused by Buffer Card Failure on 26-35;defective Reed Switches in Others.Card Replaced,Switches Repaired | /03L-0:control Rod 26-35 on 810103,18-51 on 810113,38-31 & 22-15 on 810114 Showed Inaccurate Position Indications.Caused by Buffer Card Failure on 26-35;defective Reed Switches in Others.Card Replaced,Switches Repaired | |
| 05000325/LER-1981-003, Forwards LER 81-003/03L-0 | Forwards LER 81-003/03L-0 | |
| 05000324/LER-1981-004, Forwards LER 81-004/03L-0 | Forwards LER 81-004/03L-0 | |
| 05000324/LER-1981-004-03, /03L-0:on 810110,during Startup,Intermediate Range Monitor a Did Not Respond to Changes in Input Signal.Monitor C Indicated Downscale When on Range 7.On 810111 Monitor E Indicated Downscale While Monitor C Still Inoperable | /03L-0:on 810110,during Startup,Intermediate Range Monitor a Did Not Respond to Changes in Input Signal.Monitor C Indicated Downscale When on Range 7.On 810111 Monitor E Indicated Downscale While Monitor C Still Inoperable | |
| 05000325/LER-1981-004, Forwards LER 81-004/03L-0 | Forwards LER 81-004/03L-0 | |
| 05000325/LER-1981-004-03, /03L-0:on 810118,during Control Rod Operability Check,Pt 14.1,rod 26-07 Would Not Select.Caused by Loose Solder Joint in Rod Select Switch Due to Frequent Use of Switch.New Solder Joint Made | /03L-0:on 810118,during Control Rod Operability Check,Pt 14.1,rod 26-07 Would Not Select.Caused by Loose Solder Joint in Rod Select Switch Due to Frequent Use of Switch.New Solder Joint Made | |
| 05000325/LER-1981-005, Forwards LER 81-005/03L-0 | Forwards LER 81-005/03L-0 | |
| 05000325/LER-1981-005-03, /03L-0:on 810101,during Normal Surveillance, Discovered Secondary Containment 20 Ft Elevation Inner Air Lock Door Inoperable Due to Missing Gasket Sealing Matl. Caused by High Personnel Traffic.Gasket Replaced | /03L-0:on 810101,during Normal Surveillance, Discovered Secondary Containment 20 Ft Elevation Inner Air Lock Door Inoperable Due to Missing Gasket Sealing Matl. Caused by High Personnel Traffic.Gasket Replaced | |
| 05000324/LER-1981-005-03, /03L-0:on 810113,during Normal Surveillance, Secondary Containment 20-ft Elevation Outer Air Lock Personnel Door Found Not Sealing.Caused by Heavy Personnel Traffic Through Door.Gasket Repaired | /03L-0:on 810113,during Normal Surveillance, Secondary Containment 20-ft Elevation Outer Air Lock Personnel Door Found Not Sealing.Caused by Heavy Personnel Traffic Through Door.Gasket Repaired | |
| 05000324/LER-1981-005, Forwards LER 81-005/03L-0 | Forwards LER 81-005/03L-0 | |
| 05000324/LER-1981-006-03, /03L-0:on 810115,when Main Steam Line Isolation Valve F028C Reopened During Test P.T.1.3.1P-2,main Steam Line C Indicated Min Flow.Cause Undetermined.Investigation Will Be Performed During Future Outage | /03L-0:on 810115,when Main Steam Line Isolation Valve F028C Reopened During Test P.T.1.3.1P-2,main Steam Line C Indicated Min Flow.Cause Undetermined.Investigation Will Be Performed During Future Outage | |
| 05000324/LER-1981-006, Forwards LER 81-006/03L-0 | Forwards LER 81-006/03L-0 | |
| 05000325/LER-1981-006, Forwards LER 81-006/03L-0 | Forwards LER 81-006/03L-0 | |
| 05000325/LER-1981-006-03, /03L-0:on 810101,containment Atmospheric Monitor, 1-CAC-ATH-1259-2 Found Out of Calibr.Caused by Instrument Drift.Monitor Recalibr & Returned to Svc | /03L-0:on 810101,containment Atmospheric Monitor, 1-CAC-ATH-1259-2 Found Out of Calibr.Caused by Instrument Drift.Monitor Recalibr & Returned to Svc | |
| 05000324/LER-1981-007, Forwards LER 81-007/03L-0 | Forwards LER 81-007/03L-0 | |
| 05000325/LER-1981-007-03, /03L-0:on 810220,observed 2-inch Discrepancy Between Level Indicators of Suppression Pool Level Transmitters 1-CAC-LT-2601 & 2602.Caused by Insufficient Venting of 2602 Transmitter High Side Sensing Line | /03L-0:on 810220,observed 2-inch Discrepancy Between Level Indicators of Suppression Pool Level Transmitters 1-CAC-LT-2601 & 2602.Caused by Insufficient Venting of 2602 Transmitter High Side Sensing Line | |
| 05000325/LER-1981-007, Forwards LER 81-007/03L-0 | Forwards LER 81-007/03L-0 | |
| 05000324/LER-1981-007-03, /03L-0:on 810115,Group 1 Isolation Signal Received on Reactor Protection Sys Trip Channel B.Caused by Failure of Relay Coil,Model P/N 12HFAS1A49F Due to Insulation Breakdown.Coil Replaced | /03L-0:on 810115,Group 1 Isolation Signal Received on Reactor Protection Sys Trip Channel B.Caused by Failure of Relay Coil,Model P/N 12HFAS1A49F Due to Insulation Breakdown.Coil Replaced | |
| 05000325/LER-1981-008-03, /03L-0:on 810106,while Performing Primary Containment Leak Rate Testing of Personnel Airlock Doors, Discovered That Drywell Exterior Airlock Door Leakage Rate Exceeded Limits.Caused by Tubing Fitting Lodged in Door | /03L-0:on 810106,while Performing Primary Containment Leak Rate Testing of Personnel Airlock Doors, Discovered That Drywell Exterior Airlock Door Leakage Rate Exceeded Limits.Caused by Tubing Fitting Lodged in Door | |
| 05000325/LER-1981-008, Forwards LER 81-008/03L-0 | Forwards LER 81-008/03L-0 | |
| 05000324/LER-1981-009-04, /04T-0:on 810128,radwaste Sys Liquid Effluent Discharge High Range Indicator/Recorder Found to Have Recorded Release Rate Less than Actual,Causing Tech Spec Limit to Be Exceeded.Caused by Loose Mechanical Linkage | /04T-0:on 810128,radwaste Sys Liquid Effluent Discharge High Range Indicator/Recorder Found to Have Recorded Release Rate Less than Actual,Causing Tech Spec Limit to Be Exceeded.Caused by Loose Mechanical Linkage | |
| 05000325/LER-1981-009, Forwards LER 81-009/03L-0 | Forwards LER 81-009/03L-0 | |
| 05000325/LER-1981-009-03, /03L-0:on 810115,sys Oil Cooler Inlet Isolation Valve 1-E51-F046 Would Not Open from RTGB Resulting in Reactor Core Isolation Cooling Inoperability.Caused by Incorrect Motor Control Ctr Key Lock Switch Position | /03L-0:on 810115,sys Oil Cooler Inlet Isolation Valve 1-E51-F046 Would Not Open from RTGB Resulting in Reactor Core Isolation Cooling Inoperability.Caused by Incorrect Motor Control Ctr Key Lock Switch Position | |
| 05000324/LER-1981-009, Forwards LER 81-009/04T-0 | Forwards LER 81-009/04T-0 | |
| 05000325/LER-1981-010, Forwards LER 81-010/03L-0 | Forwards LER 81-010/03L-0 | |
| 05000325/LER-1981-010-03, /03L-0:on 810120,upon Auto Initiation After Reactor Scram,Rcic Turbine Failed to Accelerate to Idle Speed,Making RCIC Inoperable.Caused by Dirty Contacts in Turbine Steam Inlet Supply Valve 1-E51-F045.Contacts Cleaned | /03L-0:on 810120,upon Auto Initiation After Reactor Scram,Rcic Turbine Failed to Accelerate to Idle Speed,Making RCIC Inoperable.Caused by Dirty Contacts in Turbine Steam Inlet Supply Valve 1-E51-F045.Contacts Cleaned | |
| 05000324/LER-1981-010, Forwards LER 81-010/03L-0 | Forwards LER 81-010/03L-0 | |
| 05000324/LER-1981-010-03, /03L-0:on 810120,RHR Svc Water Subsys a Suction valve,2-SW-V101,would Not Open Fully.Caused by Two Hex Nuts on Input Shaft of Valve Motor Operator,Model H3BC-SMB-00, Freezing to Shaft.Nuts & Shaft Reworked & Lubricated | /03L-0:on 810120,RHR Svc Water Subsys a Suction valve,2-SW-V101,would Not Open Fully.Caused by Two Hex Nuts on Input Shaft of Valve Motor Operator,Model H3BC-SMB-00, Freezing to Shaft.Nuts & Shaft Reworked & Lubricated | |
| 05000324/LER-1981-011-03, /03L-0:on 810120 & 0123,actual Pool Level Determined in Excess of Upper Tech Spec Limit.Caused by Improper Calibr Data & Calibr Procedure Inadequacy.Procedure Revision Underway & Indicators Correctly Calibr | /03L-0:on 810120 & 0123,actual Pool Level Determined in Excess of Upper Tech Spec Limit.Caused by Improper Calibr Data & Calibr Procedure Inadequacy.Procedure Revision Underway & Indicators Correctly Calibr | |
| 05000324/LER-1981-011, Forewards LER 81-011/03L-0 | Forewards LER 81-011/03L-0 | |
| 05000325/LER-1981-011-03, /03L-0:on 810121,during Routine Shutdown Operation,Seat Leakage Discovered on Reactor Recirculation Sample Inboard Isolation Valve 1-B32-F019.Cause Unknown. Valve Will Be Inspected & Repaired During Next Outage | /03L-0:on 810121,during Routine Shutdown Operation,Seat Leakage Discovered on Reactor Recirculation Sample Inboard Isolation Valve 1-B32-F019.Cause Unknown. Valve Will Be Inspected & Repaired During Next Outage | |
| 05000325/LER-1981-011, Forwards LER 81-011/03L-0 | Forwards LER 81-011/03L-0 | |
| 05000324/LER-1981-012-03, /03L-0:on 810320,wiring Deficiency Associated W/ Actuation Switch Discovered That Prevented Switch Operation. Caused by Improper Writing of Field Revision to Plant Mods Requiring Installation of Switches | /03L-0:on 810320,wiring Deficiency Associated W/ Actuation Switch Discovered That Prevented Switch Operation. Caused by Improper Writing of Field Revision to Plant Mods Requiring Installation of Switches | |
| 05000325/LER-1981-012-03, /03L-0:on 810122,rod 26-35 Did Not Have Position Indication at Position 03 & Rod 34-35 Did Not Have Position Indication at Position 02.Caused by Defective Rod Position Indication Reed Switches.Corrective Maint Will Be Comple | /03L-0:on 810122,rod 26-35 Did Not Have Position Indication at Position 03 & Rod 34-35 Did Not Have Position Indication at Position 02.Caused by Defective Rod Position Indication Reed Switches.Corrective Maint Will Be Completed | |
| 05000325/LER-1981-012, Forwards LER 81-012/03L-0 | Forwards LER 81-012/03L-0 | |
| 05000324/LER-1981-012, Forwards LER 81-012/03L-0 | Forwards LER 81-012/03L-0 | |
| 05000324/LER-1981-013-03, /03L-0:on 810119,HPCI Sys Component Test Tp 9.3.a Could Not Be Completed.Caused by Failed Motor on CST Suction Valve F004.Motor Sent to Svc Contractor to Be Repaired | /03L-0:on 810119,HPCI Sys Component Test Tp 9.3.a Could Not Be Completed.Caused by Failed Motor on CST Suction Valve F004.Motor Sent to Svc Contractor to Be Repaired | |
| 05000324/LER-1981-013, Forwards LER 81-013/03L-0 | Forwards LER 81-013/03L-0 | |
| 05000325/LER-1981-013, Forwards LER 81-013/03L-0 | Forwards LER 81-013/03L-0 | |
| 05000325/LER-1981-013-03, /03L-0:on 810122,rod Worth Minimizer Sys Rod Blocks Were Received W/Proper Adherence to Control Rod Pattern Pull Sheet.Caused by Inadequate Procedures.Rods Pulled to Correct Position | /03L-0:on 810122,rod Worth Minimizer Sys Rod Blocks Were Received W/Proper Adherence to Control Rod Pattern Pull Sheet.Caused by Inadequate Procedures.Rods Pulled to Correct Position | |