| | | Reporting criterion |
|---|
| 05000305/LER-1981-003-03, /03L-0:on 810122,supply Thermal Overloads Tripped During Testing of Valve CC400B (Component Cooling Water Inlet to Residual Heat Exchanger 1B).Caused by Wiring Error. Wiring Fault Identified & Corrected | /03L-0:on 810122,supply Thermal Overloads Tripped During Testing of Valve CC400B (Component Cooling Water Inlet to Residual Heat Exchanger 1B).Caused by Wiring Error. Wiring Fault Identified & Corrected | |
| 05000305/LER-1981-003, Forwards LER 81-003/03L-0 | Forwards LER 81-003/03L-0 | |
| 05000305/LER-1981-005-03, Apparent Discrepancy Between Tech Specs & Test Procedure Reported as Inadequacy in Implementation of Controls.Review Indicated That Test Sequence Conforms W/Tech Spec.Tech Spec Revised for Clarity | Apparent Discrepancy Between Tech Specs & Test Procedure Reported as Inadequacy in Implementation of Controls.Review Indicated That Test Sequence Conforms W/Tech Spec.Tech Spec Revised for Clarity | |
| 05000305/LER-1981-006, Forwards LER 81-006/03L-0 | Forwards LER 81-006/03L-0 | |
| 05000305/LER-1981-010-01, /01T-0:on 810330,nonradioactive Liquid Found Discharged from Waste Neutralizing Tank to Svc Water Pretreatment Lagoon.Caused by Error in Calculation of Allowable Discharge Rates.Proposed Tech Spec Submitted | /01T-0:on 810330,nonradioactive Liquid Found Discharged from Waste Neutralizing Tank to Svc Water Pretreatment Lagoon.Caused by Error in Calculation of Allowable Discharge Rates.Proposed Tech Spec Submitted | |
| 05000305/LER-1981-010, Forwards LER 81-010/01T-0 | Forwards LER 81-010/01T-0 | |
| 05000305/LER-1981-013-03, /03L-0:on 810422,during Facility Shutdown for Leak Rate Test,Investigation Revealed Cracked Root Weld on Vent Valve of Containment Sump B to RHR Pump 1B Piping.Caused by Sharp Blow of Unknown Origin.Repair Scheduled | /03L-0:on 810422,during Facility Shutdown for Leak Rate Test,Investigation Revealed Cracked Root Weld on Vent Valve of Containment Sump B to RHR Pump 1B Piping.Caused by Sharp Blow of Unknown Origin.Repair Scheduled | |
| 05000305/LER-1981-013, Forwards LER 81-013/03L-0 | Forwards LER 81-013/03L-0 | |
| 05000305/LER-1981-014-03, /03X-1:on 810507,during Test of Presurizer Level Channels,Found Transmitter to Channel Lt 427 Out of Spec Low,Implying That High Level Reactor Trip Relay Would Have Tripped.Will Change Transmitters | /03X-1:on 810507,during Test of Presurizer Level Channels,Found Transmitter to Channel Lt 427 Out of Spec Low,Implying That High Level Reactor Trip Relay Would Have Tripped.Will Change Transmitters | |
| 05000305/LER-1981-015, Forwards LER 81-015/03L-0 | Forwards LER 81-015/03L-0 | |
| 05000305/LER-1981-015-03, /03L-0:on 810510,steam Flow Transmitter Found Out of Calibr Resulting in Bi Steam Flow & hi-hi Steam Flow Trip Settings Less Conservative than Tech Spec.Caused by Instrument Drift.Transmitter Recalibr | /03L-0:on 810510,steam Flow Transmitter Found Out of Calibr Resulting in Bi Steam Flow & hi-hi Steam Flow Trip Settings Less Conservative than Tech Spec.Caused by Instrument Drift.Transmitter Recalibr | |
| 05000305/LER-1981-016-03, /03L-0:on 810515,tests Indicated That Two Foxboro RCS Flow Transmitters in Loop a Were Out of Calibr.Caused by Setpoint Drift.Transmitters Recalibr | /03L-0:on 810515,tests Indicated That Two Foxboro RCS Flow Transmitters in Loop a Were Out of Calibr.Caused by Setpoint Drift.Transmitters Recalibr | |
| 05000305/LER-1981-017-03, /03L-0:on 810515,discovered That High Pressure Reactor Trip Setpoints for Pressure Transmitters Were Higher than Tech Spec.Caused by Setpoint Drift.Instruments Recalibr | /03L-0:on 810515,discovered That High Pressure Reactor Trip Setpoints for Pressure Transmitters Were Higher than Tech Spec.Caused by Setpoint Drift.Instruments Recalibr | |
| 05000305/LER-1981-018-03, /03L-0:on 810516,testing Indicated That Low Pressure Safety Injection & Reactor Trip Were Below Tech Spec Limits for Pressure Transmitters.Caused by Instrument Drift.Sensing Lines Flushed.Amplifier Replaced | /03L-0:on 810516,testing Indicated That Low Pressure Safety Injection & Reactor Trip Were Below Tech Spec Limits for Pressure Transmitters.Caused by Instrument Drift.Sensing Lines Flushed.Amplifier Replaced | |
| 05000305/LER-1981-019, Forwards LER 81-019/03L-0 | Forwards LER 81-019/03L-0 | |
| 05000305/LER-1981-019-03, /03L-0:on 810605,during Refueling Outage,Portable Radiation Survey Instrument Checks for May Not Performed Per Tech Specs.Caused by Oversight Due to Reassignment of Personnel.Instruments Will Be Source Checked in June | /03L-0:on 810605,during Refueling Outage,Portable Radiation Survey Instrument Checks for May Not Performed Per Tech Specs.Caused by Oversight Due to Reassignment of Personnel.Instruments Will Be Source Checked in June | |
| 05000305/LER-1981-020, Forwards LER 81-020/03L-0 | Forwards LER 81-020/03L-0 | |
| 05000305/LER-1981-020-03, /03L-0:on 810606,condensate Water Storage Tank Level Went Below Tech Spec Limit.Caused by Normal Tank Water Usage During Startup & Turbine Testing Coincident W/ Demineralizer Regeneration | /03L-0:on 810606,condensate Water Storage Tank Level Went Below Tech Spec Limit.Caused by Normal Tank Water Usage During Startup & Turbine Testing Coincident W/ Demineralizer Regeneration | |
| 05000305/LER-1981-021, Forwards LER 81-021/03L-0 | Forwards LER 81-021/03L-0 | |
| 05000305/LER-1981-021-03, /03L-0:on 810611,found Visual Verification of Valve Motion & Limit Switch Not Performed During Refueling Outage for Valves Inaccessible During Normal Operation Per Iwv 3300 of 1974 ASME Code.Caused by Procedural Oversight | /03L-0:on 810611,found Visual Verification of Valve Motion & Limit Switch Not Performed During Refueling Outage for Valves Inaccessible During Normal Operation Per Iwv 3300 of 1974 ASME Code.Caused by Procedural Oversight | |
| 05000305/LER-1981-022, Forwards LER 81-022/03L-0 | Forwards LER 81-022/03L-0 | |
| 05000305/LER-1981-022-03, /03L-0:on 810619,spent Fuel Pool Boron Sampling Not Performed within Allotted Time Frame During Steady State Operation.Caused by Temporary Work Load Increase on Chemistry Staff.Sample Taken & Analyzed | /03L-0:on 810619,spent Fuel Pool Boron Sampling Not Performed within Allotted Time Frame During Steady State Operation.Caused by Temporary Work Load Increase on Chemistry Staff.Sample Taken & Analyzed | |
| 05000305/LER-1981-023-03, /03L-0:on 810621,boric Acid Found Leaking from Instrument Isolation Valve CVC-11188.Caused by Leaking Diaphragm & Corroded Bonnet.Transfer Pump 1A Isolated & Bonnet Assembly Replaced | /03L-0:on 810621,boric Acid Found Leaking from Instrument Isolation Valve CVC-11188.Caused by Leaking Diaphragm & Corroded Bonnet.Transfer Pump 1A Isolated & Bonnet Assembly Replaced | |
| 05000305/LER-1981-023, Forwards LER 81-023/03L-0 | Forwards LER 81-023/03L-0 | |
| 05000305/LER-1981-024-03, /03L-0:on 810730,low Boric Acid Heat Tracing Temp Detected on Section of Piping Between Boric Acid Tanks & Safety Injection Pumps.Caused by Removal of Insulation from Boric Acid Heat Tracing Circuits to Permit Maint | /03L-0:on 810730,low Boric Acid Heat Tracing Temp Detected on Section of Piping Between Boric Acid Tanks & Safety Injection Pumps.Caused by Removal of Insulation from Boric Acid Heat Tracing Circuits to Permit Maint | |
| 05000305/LER-1981-024, Forwards LER 81-024/03L-0 | Forwards LER 81-024/03L-0 | |
| 05000305/LER-1981-025-03, /03L-0:on 810807,safety Injection High Containment Pressure Setpoint Discovered to Be Less Conservative than Required by Tech Spec Due to Foxboro Containment Pressure Transmitter Out of Calibr.Caused by Instrument Drift | /03L-0:on 810807,safety Injection High Containment Pressure Setpoint Discovered to Be Less Conservative than Required by Tech Spec Due to Foxboro Containment Pressure Transmitter Out of Calibr.Caused by Instrument Drift | |
| 05000305/LER-1981-025, Forwards LER 81-025/03L-0 | Forwards LER 81-025/03L-0 | |
| 05000305/LER-1981-026, Forwards LER 81-026/03L-0 | Forwards LER 81-026/03L-0 | |
| 05000305/LER-1981-026-03, /03L-0:on 810817,auxiliary Feedwater Pump Inservice Testing Not Performed within 7 Days After Reaching Primary Temp Limit.Caused by Misinterpretation of ASME Code.Pumps Tested & Procedures Revised | /03L-0:on 810817,auxiliary Feedwater Pump Inservice Testing Not Performed within 7 Days After Reaching Primary Temp Limit.Caused by Misinterpretation of ASME Code.Pumps Tested & Procedures Revised | |
| 05000305/LER-1981-027-03, /03L-0:on 810820,during Routine Plant Tour, Excess Shaft Leakage Noted on 1B Boric Acid Transfer Pump. Caused by Corroded Pipe Plug in Boric Acid Pump Housing.Plug Replaced W/Stainless Plug | /03L-0:on 810820,during Routine Plant Tour, Excess Shaft Leakage Noted on 1B Boric Acid Transfer Pump. Caused by Corroded Pipe Plug in Boric Acid Pump Housing.Plug Replaced W/Stainless Plug | |
| 05000305/LER-1981-027, Forwards LER 81-027/03L-0 | Forwards LER 81-027/03L-0 | |
| 05000305/LER-1981-028-03, /03L-0:on 810828,supply Breaker Overloads Tripped During Testing of Component Cooling Water Inlet Valve CC 400B.Caused by Worn Gears in Operator.Worn Gears Replaced | /03L-0:on 810828,supply Breaker Overloads Tripped During Testing of Component Cooling Water Inlet Valve CC 400B.Caused by Worn Gears in Operator.Worn Gears Replaced | |
| 05000305/LER-1981-029-03, /03L-0:on 810828,check Damper SBV-3A Failed to Open Resulting in Inability of Sys to Perform to Design. Caused by Hydraulic Oil Leak Resulting from Pump Seals Wearing Out.Pump Replaced & Valve Tested Satisfactorily | /03L-0:on 810828,check Damper SBV-3A Failed to Open Resulting in Inability of Sys to Perform to Design. Caused by Hydraulic Oil Leak Resulting from Pump Seals Wearing Out.Pump Replaced & Valve Tested Satisfactorily | |
| 05000305/LER-1981-030-03, /03L-0:on 810903,surveillance Procedure Found to Incorrectly Measure Shield Bldg Vent Sys Exhaust Flow from Annulus.Caused by Surveillance Procedures Written to Demonstrate Original Design Criteria | /03L-0:on 810903,surveillance Procedure Found to Incorrectly Measure Shield Bldg Vent Sys Exhaust Flow from Annulus.Caused by Surveillance Procedures Written to Demonstrate Original Design Criteria | |
| 05000305/LER-1981-030, Forwards LER 81-030/03L-0 | Forwards LER 81-030/03L-0 | |
| 05000305/LER-1981-031-03, /03L-0:on 811002,sampling & Analysis of Chemical & Vol Control Sys Boron Recycle Monitor Tank 1A Indicated Tritium Activity Exceeded Max Allowable Limits.Caused by Increased Tritium Content in RCS & Boric Acid Evaporator | /03L-0:on 811002,sampling & Analysis of Chemical & Vol Control Sys Boron Recycle Monitor Tank 1A Indicated Tritium Activity Exceeded Max Allowable Limits.Caused by Increased Tritium Content in RCS & Boric Acid Evaporator | |
| 05000305/LER-1981-032-01, /01T-0:on 811013,high Solids Content of Liquid Waste Discharge from Waste Neutralizing Tank to Svc Water Pretreatment Lagoon Exceeded ETS Increase Limits.Caused by Personnel Error in Calculation of Allowable Discharge Rates | /01T-0:on 811013,high Solids Content of Liquid Waste Discharge from Waste Neutralizing Tank to Svc Water Pretreatment Lagoon Exceeded ETS Increase Limits.Caused by Personnel Error in Calculation of Allowable Discharge Rates | |
| 05000305/LER-1981-032, Informs That Repts for LER 81-032/01T-0 & LER 81-033/01T-0 Were Incorrectly Submitted as LER 81-032/03L-0 & LER 81-033/03L-0 | Informs That Repts for LER 81-032/01T-0 & LER 81-033/01T-0 Were Incorrectly Submitted as LER 81-032/03L-0 & LER 81-033/03L-0 | |
| 05000305/LER-1981-033-01, /01T-0:on 811016,diesel Generator 1B Removed from Svc While Component Cooling Water Exchanger 1A Out of Svc. Caused by Personnel Error.Personnel Advised of Importance of Maintaining Redundant Equipment | /01T-0:on 811016,diesel Generator 1B Removed from Svc While Component Cooling Water Exchanger 1A Out of Svc. Caused by Personnel Error.Personnel Advised of Importance of Maintaining Redundant Equipment | |
| 05000305/LER-1981-034-03, /03L-0:on 811018,during Normal operations,1B Zone SV Fan Started Automatically.Caused by Solenoid Failure Due to Burned Out Coil in Safe Position Automatically Starting Fan & Opening Damper.Coil Replaced | /03L-0:on 811018,during Normal operations,1B Zone SV Fan Started Automatically.Caused by Solenoid Failure Due to Burned Out Coil in Safe Position Automatically Starting Fan & Opening Damper.Coil Replaced | |
| 05000305/LER-1981-034, Forwards LER 81-034/03L-0 | Forwards LER 81-034/03L-0 | |
| 05000305/LER-1981-035, Forwards LER 81-035/03L-0,LER 81-014/03X-1 & Corrected LER 81-015/03X-2 | Forwards LER 81-035/03L-0,LER 81-014/03X-1 & Corrected LER 81-015/03X-2 | |
| 05000305/LER-1981-035-03, /03L-0:on 811030,during Sampling & Analysis of Chemical & Vol Control Sys,Noted Monitor Tank Indicated Total Tritium Activity Exceeded Tech Specs.No Cause Stated. Liquid Transferred to Reduce Setpoint | /03L-0:on 811030,during Sampling & Analysis of Chemical & Vol Control Sys,Noted Monitor Tank Indicated Total Tritium Activity Exceeded Tech Specs.No Cause Stated. Liquid Transferred to Reduce Setpoint | |
| 05000305/LER-1981-036-03, Motor Drive Auxiliary Feedwater Lube Oil Pump Continued to Run When Pump 1A Stopped.Caused by Excessive Wear & Misalignment of Switch Linkage Mechanism.Worn Parts Replaced | Motor Drive Auxiliary Feedwater Lube Oil Pump Continued to Run When Pump 1A Stopped.Caused by Excessive Wear & Misalignment of Switch Linkage Mechanism.Worn Parts Replaced | |
| 05000305/LER-1981-037-03, /03L-0:on 811109,intermittent Deviation in Steam Flow Indication Between Similar Channels Observed.Caused by Electronic Failure in Circuit Board in Transmitter. Transmitter Repaired & Returned to Svc | /03L-0:on 811109,intermittent Deviation in Steam Flow Indication Between Similar Channels Observed.Caused by Electronic Failure in Circuit Board in Transmitter. Transmitter Repaired & Returned to Svc | |
| 05000305/LER-1981-037, Forwards LER 81-037/03L-0 | Forwards LER 81-037/03L-0 | |
| 05000305/LER-1981-038-03, /03L-0:on 811113,during Surveillance Testing on Shield Bldg Vent Sys,Check Damper SBV-10A Failed Shut.Caused by Ruptured Diaphragm Which Separates Motor from Oil Reservoir.Motor Replaced | /03L-0:on 811113,during Surveillance Testing on Shield Bldg Vent Sys,Check Damper SBV-10A Failed Shut.Caused by Ruptured Diaphragm Which Separates Motor from Oil Reservoir.Motor Replaced | |
| 05000305/LER-1981-038, Forwards LER 81-038/03L-0 | Forwards LER 81-038/03L-0 | |
| 05000305/LER-1981-039-03, /03X-1:on 811218,leaking Weld on Discharge Side of 1C Charging Pump Relief valve,CVC-101C,discovered.Caused by Vibrations & Pulsations in Associated Piping.Pipe Section Replaced.Design Change in Progress | /03X-1:on 811218,leaking Weld on Discharge Side of 1C Charging Pump Relief valve,CVC-101C,discovered.Caused by Vibrations & Pulsations in Associated Piping.Pipe Section Replaced.Design Change in Progress | |