{{#Wiki_filter:8 7 6 5 4 3 2 SH. 2 -t--- OUTSIDE 8031-M-69 INSIDE SHIELD WALL I I ~
§
-- - -.- .-- .. - .. - -*-.. -*. - **-.*-*--**- **t.. -*. -**-**-.. -**-**-.. -*. -**- .*-. --*. - **-.*-.. --..
- i -- -- -- __, -
i
- ---*. - **-.*-*.-**---- -. -*. -**-.*-**-**- **-*.-**-**- . *-.. ., 1. 2" DECONTAMINATION WASH CONNECTIONS.
PUMP TEST CONNECTJONi I ---' 111 I !..-( 2. FLEXIBLE CABLE CONTROLS GASHOLDER BYPASS VALVE. r- -- -- -- -- -- -- -- -- - - -- : 6.- - COMPRErc5l~~E&,irnNGS
- 3. THIS ANALYZER NORMALLY SAMPLES DOWNSTREAM H
,I 1
! I
--j -
121 I
-0 R
/ '- /
OF AFTERCDNDENSER. FC - - - - - - - - ....-- R TO XA-14l
- 4. PACKLESS DESIGN. H
'i-.:-----{)<:J-----t\<J-------""T-{Xf....1....,~C-l' I i
SAMPLE RETURN I * / ' / ' I -! s 5. DELETED. s 1166 NE ~ C..~i'-"'11""'{><.J-"T""-~--i : _ ! __ ~~-*-------~
- 6. THREE-WAY VALVE TO BE LOCATED AT PIPING LOW POINT.
I IOP9H
- I i 1-@-1--------~ j .--------,-S
- 7. 24" HBD-172 MUST BE AT LEAST 6 FEET LONG AND LOCATED I
cYR' BELOW THE AFTERCONDENSER AIR COOLER DRAIN. I I '
-o'-/ R TD AR-143
+--@- @ -~-i--s
- I
- -- -- .,--- "-i' - -
141 B. DESIGN. FABRICATION. MATERIAL PROCUREMENT, ERECTION I
~
TO AAHH-143 ANO TESTING FOR ALL PIPING AND VALVES SHOWN 1162 r-
.- - L - J I '
I / ' / I ON THIS P&!D MAY BE IN ACCORDANCE WITH THE REQUIREMENTS
*o*
.f'iYj__ - /R : OF THE PIPING CLASS DESIGNATION, DESIGN CODE L - __,. . _. /'- ! WITH THE FOLLOWING EXCEPTIONS:
ll63
~
il1au1~
, TRAP
**- **SURGE voLuMETANK
**- *SEPARATOR i:tOTs"TuR"E; I
H%-t-'i'lf-t-N-D_TE __::.._ - .,....__ - - - --s TO AAH-143 (al CLEANING REQUIREMENTS SHALL BE PER THE ORIGINAL LINE CLASS DESJGNA TION.
- -------. ----*-- ----- - -. ~ '.~R LIOUID DRAIN 'rS-!-------~i------l- <bl WELDING PROCEDURES TO BE USED SHALL BE AS REQUIRED
,@ /'
PER THE ORIGINAL LINE CLASS DESIGNATION. 118l
- 9. DELETED
- G SURGE TANK ASSEMSL Y (10T4-t0l SPAN GAS
- 10. HEAT TRACING TROUBLE ALARM LOCATED ON C873. G I 178 1 1167 11. LOOP SEAL DISCHARGE LINE MUST BE AT LEAST 11'-9" FROM
©
~* SWAGELOK
<,-+----.()<:J-----...'..----------f----::-1 THE BOTTOM OF THE LOOP SEAL TUBE FITTING CHILLED WATER OUT 1171 SAt.IPLE I 12. REDUNDANT HEAT TRACING SHALL BE INSTALLED.
- 13. LG-102. YS-117, F0-117, VALVES 1141, 1080, 1131.1132, COOLER '----'-----I CE-155. FG-155 AND SX-155 ALL TO BE LOCATED IN SPARE CHILLED WATER IN <,......;...--~><J--------------i IOE947 I RECOMBINER ROOM.
'---....----' ZERO GAS 1170 I I I 14. REDUNDANT HEAT TRACING AND CONTROL llQ6A & Bl TO BE I
FC I 168 I t-- I 171 (;;'\ INSTALLED ON GCC-102.
-------~- -:-~-r-~
L __________ J_ ___ ~-t~i_---~--LW I
- 15. TE-106 A & B AND TE-107 ARE MAGNETIC SURFACE MOUNT TYPE.
UPSTRft~p5~ ~i~~TM81NER <,--i-------i)<J----- r-- ~ JG. DELETED.
~
+------,
1
- -.... I I I ~ ~
1158 FC I I
- 17. DELETED.
I
- 18. DENOTES PROCESS RADIATION MONITORING. SEE P&ID M-26 FDR DETAILS.
F 1157 FC W SWAGELDK 19. DELETED. F ANAL YlER t.400ULE, IOC162 TUBE FITTING READOUT AND CONTROL MODULE, IOC163 20. AFTERCDNDENSER/HOLDUP PIPE LOOP SEALS TO BE INSTALLED I : _________________________________________________________ J IN REACTOR ENCLOSURE EQUIPMENT DRAIN SUMP.
'--- - ----- -- * - - - - - - - * * - - .. - - - - . - - . . . - - * - - - - ** - .... - - - - - - - - - - - - - - - - . - - .. - - - - - - - - .... - - .. - - - - - - - .. 1
- 21. DELETED
- 22. DELETED.
- 23. K SIZE CYLINDERS ARE TD BE MOUNTED VERTICALLY. SUPPORTS REQUIRED. H2 CONNECTIONS ANO SAFETY RELIEF VALVES ARE TO BE AT LEAST 3 FEET FROM ELECTRICAL WIRING OR EOUIPMENT.
RELIEF VALVE DISCHARGE TO BE UPWARDS TOWARD OPEN AREAS AWAY FROM BOTTLES. ADJACENT STRUCTURES, AND PERSONNEL. CH. A 0 z LOW
- 24. FITTINGS FOR THE REGULATORS ANO MANIFOLDS SHOULD BE STANDARD LINDE OR EOU!VALENT.
CH.A Dz HIGH
- 25. CONNECT OBD-119 AS CLOSE AS POSSIBLE TO VALVE 1116 IN GCC-106.
CH. A 0 z MONITOR TROUBLE
- 26. CELE TED.
- 27. DELETED.
E 28. PSV-140 INLET ELBOW AND THE ATTACHED FLANGE E ARE STAINLESS STEEL, SEE ECR 95-01564.
- 29. HSS-143 JS PART OF AIT-143.
HSS-143A IS PART OF AIT-J<3A. HSS-143B IS PART OF AIT-1438. 1 t82A I 181A JO, A PORTION OF THIS PIPING JS CARBON STEEL. ll. POINT CONNECTIONS SHOWN ON DRAWING M-207-00274 SH.2.
- 32. DELETED.
LIQUID DRAIN .,_-!-----"""'--1/~--....,--t-; 1183A SURGE TANK ASSEMBLY (JAT440l CHILLED WATER OUT s-+----~()-----...'..----------r--:-'.°:":'.:::-::-1 SAt.tPLE 6c"X 1171A ~ SPAN GAS ZERO GAS TO I CciOLEii FC I 167A H 2 ANALYZERS
.._ IAE9'47 __, I D
CHILLED WATER IN i,-----~>~---------------1 1170A L __
~
J!::Y r- - NO s ($v\, J!::Y ZERO GAS M-69 D I -1"IL'i I FC 116BA ISH.1 G.21 I -~ r-- ~ ~ SPAN GAS TO
- M-69 H 2 ANALYZERS
!SH.I 0,61 AIR 1157A FC 1159A
>k* SWAGELOK TO UNIT 2 ANALYZER t.400ULE, IACl6'4 TUBE FITTING READOUT AND CONTROL lo40DULE, IAC16S
- M-69 11<° COPPER TUBING M-69
*---------------------------------------------------*-----* <SH.I A,6) ISH.4 C,5l N
c =-?--~ 1 c I Il============L: -r--===__,==, MINIMUM 3* DIAMETER i*-**-------**--*-**-**-**--*-**-**-**t**-*--**-**-**-**-**--*-**-**-**-**-**=*=*=*: - ! -I: - - - - - - - - I ,.... .... - * * -* * - * * -.... - - * - * * -* .. - * .. - * * -.. * - ** - * * - * * -* * - * *- * * - * * -.... ., PUMP TEST CONNECTIDNio. 02 - - - - - - - 71 -aH~~0~} CH.Bl.Dz FDR PIGTAILS COMPRESSION FITTINGS - -- -- -- -- - - - -- -- -r- ~ 0 c-------r--t~~06c..>> CH. B 0 2 LOW (CONNECTION 100/.
! '/ ' @ -------t ICAPPEOJ 111 -02 1t6B H2 WHEN REQUIRED
! i I/ -~ CH.B 0 z HIGH s'@ .?
SAMPLE RETURN FC 11 I (21 I 1165B I --------r~-1-JJ,R /o,R L L.--------7-aH~~o~
- CH. B D 2 MONITOR TROUBLE
~ -i-1~+----,-l____===-=======t}TOXA-143 H2 SPAN GAS ZERO GAS I <BY PECOI 1001. Ni
-+ - t-14--!- --OR 'dR @ - f - - - - - - - --i -S
<BY PECDI L.. - .. - .. - --- ::E__'.'~~E.:_
1 1'7'1t------r-i 11628 - - i / '. / ' J - - - - - - - --i °"5 :: .: ~: - *- - ** - ** - * - i
+- --@- ,-- - ~ -i--s TO AR-143 11828 11818 11638 TO AAHH-143
..--!-------v1-------t-
.---L - @y '6
/ 'R I
- INCORP, EC 625789 REV. 0 PER WO 4877768
- ADDED JUMPER AROUND 1183B ANO VALVES 1181B AND B LIOUID DRAIN 11838 I 1s1 * -
+--'-I NOTE 29 i436
_J - L2L_
-i--s l-.jljl""ll~8~2B~*~[B~*~7-~8~J.::::-,,.,,...-::-=:~::-::,,.,,...,,..,,,,.,,...,,,,,...,,,,.,.,:::;-::----l-l-Tl~=-i B
' PARTIAL INCORP. EC 625789 REV. 0 PER WO 4848554.
- - -+.,~~-.+-- - - ---_,. - - - ~ - __,... TO AAH-143 47 f pgif. 6~~n~o At:15%N032'. 1&:~-t1~D VALVES 11816 AND SURGE TANK ASSEMBLY
<IBT440l I ;{.
46 ', ~~~~rg'*N~~E6~~:1~-W* o PER WO 4735249.
;f8 ADDED CAPS. [E.7-BJ.
CHILLED WATER OUT ',...-+----~:J-----...'..----------f--::-'.°:":'.::"°'.:-l SAt.IPLE 6c"X 45 0 ~~~~lb"'N~~E4;~~37 REV.6 PER WO '180185. EJ'll JCV JI<* 1 !71B ~ SPAN GAS 1 [E 1].
'.-----.()<:J----------------i I COOLER 1167B IBE947 DESCRIPTION CHILLED WATER IN I
(PCT'\ L- - ll 708 I :
@ ~ TABLE OF ADDITIONS & CHANCES
--------1-----:--~I~-
USE ONLY PRINTS SHOWING LATEST DATE ZERO GAS I L __________ j_ ___ ~-l~+------ -1"IL'i I FC 11688 MECHANICAL I 1 I ~ ~ r-- --@ P&ID N , I I , GASEOUS RAOWASTE*RECOUBINATION i I i !UNIT 1l A 1-
- c A I Llt.4ERICK GENERATING STATIOi.
\/) EXELON NUCLEAR CORP. 11578 FC SCALE DRAWN !GOS CHECKED INSPECTED APPROVED DATE
%' SWAGELOK NONE BECHTEL BECHTEL BECHTEL BECHTEL BECH BECH 2120187 TUBE FITTING ANALYZER t.400ULE, IBC16'4 READOUT AND CONTROL t,4DDULE. IBCl65 APPAOVED~B~E~C~H~TE~L~-----APPAOYED---------1 SHEET 2 OF 803 t -M-69 ' 48 8 7 6 5 4 3 2 CATEGORY Al}}