ML20213F393

From kanterella
Revision as of 02:47, 20 January 2021 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Nonproprietary Version of RESAR-SP/90 Westinghouse Advanced PWR Module 13, Auxiliary Sys
ML20213F393
Person / Time
Site: 05000601
Issue date: 10/31/1986
From:
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To:
Shared Package
ML19292G244 List:
References
NUDOCS 8611140187
Download: ML20213F393 (376)


Text

.__

.O RESAR-SP/90 O AUXILIARY SYSTEMS l

WESTINGHOUSE A VANCED PRESSURIZED O WATER REACTOR

!O i l

I '@*;~;

1 .

^ .

c .m. .

88 O

O STANDARD PLANT DESIGN rasan m8He K

i NESTINGHOUSE CLASS 3 I

' I i

i

! i

! i I

l l

l i

1 1

, I i

4 1,

1

)

i I

I i

i l

1 1

4 l l i

i l

I l

1 1

l l

i

WAPWR-AS OCTOBER 1986 5539e
1d

-, ppm- _m

.___ _ .__ m . . _ _ _ _ . . - _ . _ _ _ - _ _ _ . - . _ _ -

TABLE OF CONTENTS i

Reference SAR fO j Section Title &

Section Status i

1.0 INTRODUCTION

AND GENERAL DESCRIPTION OF PLANT 1.1-1 1

1.1 INTRODUCTION

1.1-1 I (

! 1.2 GENERAL PLANT DESCRIPTION 1.2-1 II l

! 1.2.2 Principal Design Criteria 1,2-1 II ,

1.6 MATERIAL INCORPORATED BY REFERENCE 1.6-1 11 l

! 1.8 CONFORMANCE WITH THE STANDARD REVIEW PLAN 1.8-1 11 l 2.0 SITE CHARACTERISTICS 2.0-1 NA 3.0 DESIGN OF STRUCTURES, COMPONENTS, EQUIPMENT 3.0-1 NA [

I j AND SYSTEMS l 4.0 REACTOR 4.0-1 NA -

5.0 REACTOR COOLANT SYSTEM AND CONNECTED SYSTEMS 5.0-1 NA

{

l 6.4 CONTROL ROOM HABITABILITY SYSTEM 6.4-1 I l l 6.4.1 Design Bases 6.4-1 I  :

6.4.1.1 Safety Design Bases 6.4-1 I 6.4.2 System Description 6.4-2 1 4 6.4.2.1 General Description 6.4-2 I 4 6.4.2.2 Component Description 6.4-3 I '

! 6.4.2.3 System Operation 6.4-4 I

{ 6.4.3 Codes and Standards 6.4-5 I

! 6.4.4 Safety Evaluation 6.4-6 I 1

j 6.4.5 Inspection and Testing Requirements 6.4-7 I  :

6.4.6 Instrumentation Application 6.4-8 I i 7.0 INSTRUMENTATION AND CONTROLS 7.0-1 NA i 8.0 ELECTRIC POWER 8.0-1 NA
9.0 AUXILIARY SYSTEMS 9.1-1 I ,

9.1 FUEL STORAGE AND HANDLING 9.1-l' I l 9.1.1 NEW FUEL STORAGE 9.1-1 I J

O WAPWR-AS i OCTOBER, 1986 l 5539e:1d i

}

I . - _ _ __ _____ _ -- _

TABLE OF CONTENTS (Continued)

Reference SAR Section Section Title Page Status 9.1.1.1 Design Bases 9.1-1 I 9.1.1.1.1 Safety Design Bases 9.1-1 I 9.1.1.2 Facility Description 9.1-2 I 9.1.1.3 Safety Evaluation 9.1-4 I 9.1.1.4 Tests and Inspections 9.1-6 I 9.1.1.5 Instrumentation Application 9.1-6 I 9.1.2 Spent Fuel Storage 9.1-6 I 9.1.2.1 Design Bases 9.1-6 I 9.1.2.1.1 Safety Design Bases 9.1-7 I 9.1.2.1.2 Power Generation Design Bases 9.1-8 I 9.1.2.2 Facilities Description 9.1-9 I 9.1.2.3 Safety Evaluations 9.1-11 I 9.1.2.4 Tests and Inspections 9.1-13 I 9.1.2.5 Instrumentation Application 9.1-13 l' 9.1.3 Spent fuel Pit Cooling System 9.1-13 I 9.1.3.1 Design Bases 9.1-14 I 9.1.3.1.1 Safety Design Bases 9.1-14 I 9.1.3.1.2 Power Generation Design Bases 9.1-18 I 9.1.3.2 System Description 9.1-19 I 9.1.3.2.1 General Description 9.1-19 I 9.1.3.2.1.1 Spent Fuel Pit Cooling System 9.1-19 I 9.1.3.2.1.2 Spent Fuel Pit Cooling (Purification Portion) 9.1-21 I 9.1.3.3 Component Data 9.1-22 I 9.1.4 Light Load Handling System (Related to 9.1-25 I Refueling) 9.1.4.1 Safety Design Bases 9.1-25 I 9.1.4.2 System Description 9.1-26 I 9.1.4.2.1 Fuel Handling Description 9.1-27 I WAPWR-AS ii OCTOBER, 1986 5539e:1d

TABLE OF CONTENTS (Continued)

Reference SAR Section Section Title Pag ~e Status 9.1.4.2.2 Refueling Procedure 9.1-28 I 9.1.4.2.2.1 Phase I - Preparation 9.1-29 I 9.1.4.2.2.2 Phase II - Reactor Disassembly 9.1-29 I 9.1.4.2.2.3 Pnase III - Fuel Handling 9.1-30 I 9.1.4.2.2.4 Phase IV - Reactor Assembly 9.1-31 1 9.1.4.2.3 Spent Fuel Cask Handling 9.1-32 I 9.1.4.2.4 Component Description 9.1-33 1 9.1.4.2.5 Applicable Design Codes 9.1-38 I 9.1.4.3 Safety Evaluation 9.1-38 I 9.1.4.3.1 Safe Handling 9.1-38 I 9.1.4.3.1.1 Refueling Machine 9.1-40 I O 9.1.4.3.1.2 Fuel Transfer System 9.1-43 I 9.1.4.3.1.3 Fuel Handling Machine 9.1-44 I 9.1.4.3.1.4 Fuel Handling Tools and Equipment 9.1-45 I 9.1.4.3.2 Seismic Conside, rations 9.1-46 I 9.1.4.3.3 Containment Pressure Boundary Integrity 9.1-46 I 9.1.4.3.4 Radiation Shielding 9.1-47 I 9.1.4.4 Inspection and Testing Requirements 9.1-47 I 9.1.4.5 Instrumentation Reg'uirements 9.1-50 1 9.1.5 Overhead Heavy Load Handling Systems 9.1-50 I 9.1.5.1 Design Bases 9.1-51 I 9.1.5.1.1 Safety Design Bases 9.1-51 I 9.1.5.1.2 Power Generation Design Bases 9.1-51 I 9.1.5.2 System Description 9.1-52 I 9.1.5.2.1 General Description 9.1-52 I 9.1.5.2.2 Cask Handling Crane 9.1-52 I 9.1.5.2.3 Containment Building Polar Crane 9.1-53 I 9.1.5.2.4 Miscellaneous Crane and Hoists 9.1-55 I O

WAPWR-AS 111 OCTOBER, 1986 5539e:1d

TABLE OF CONTENTS (Continued)

Reference SAR Section Section Title Page Status 9.1.5.3 Safety Evaluation 9.1-55 I 9.1.5.4 Tests and Inspections 9.1-56 I 9.1.5.5 Instrumentation Applications 9.1-56 I 9.2 WATER SYSTEMS 9.2-1 I 9.2.1 Essential Service Water System (ESWS) 9.2-1 III 9.2.1.1 Design Criteria 9.2-3 III 9.2.1.1.1 Safety Related Design Criteria 9.2-3  !!!

9.2.1.1.2 Fower Generation Design Criteria 9.2-4 III 9.2.1.2 System Description 9.2-5 111 9.2.1.3 Component Data 9.2-7 III 9.2.2 Component Cooling Water System (CCWS) 9.2-7 I 9.2.2.1 Design Criteria 9.2-9 I 9.2.2.1.1 Safety Related Design Criteria 9.2-9 I 9.2.2.1.2 Power Generation Design Criteria 9.2-11 I 9.2.2.2 System Description 9.2-11 I 9.2.2.3 Safety Evaluation 9.2-13 I 9.2.2.4 Major Equipment Component Data 9.2-13 I 9.2.3 Demineralized Water System 9.2-15 III 9.2.3.1 Design Bases 9.2-15 III 9.2.3.1.1 9.2.3.1.2 Safety Design Bases Power Generation Design Bases 9.2-15 9.2-15 III g

9.2.3.2 System Description 9.2-16  !!!

9.2.4 Potable and Sanitary Water System 9.2-16 III 9.2.4.1 Design Bases 9.2-16 III 9.2.4.1.1 Safety Design Bases 9.2-16 III 9.2.4.1.2 Power Generation Design Bases 9.2-16' III 9.2.4.2 System Description 9.2-17  !!!

O WAPWR-AS iv OCTOBER, 1986 5539e:1d t

TABLE OF CONTENTS (Continued)

Reference SAR O Section Title Page Section Status 9.2.5 Ultimate Heat Sink 9.2-17 III 9.2.5.1 Design Bases 9.2-18 III 9.2.5.1.1 Safety Design Bases 9.2-18  !!!

9.2.5.1.2 Power Generation Design Bases 9.2-18  !!!

9.2.5.2 System Description 9.2-19  !!!

9.2.5.3 Safety Evaluation 9.2-19 III 9.2.6 Condensate Storage and Transfer System 9.2-19 III 9.2.6.1 Design Bases 9.2-20 III 9.2.6.1.1 Safety Design Bases c.2-20 III 9.2.6.1.2 Power Generation Design Criteria 9.2-20 III 9.2.6.2 System Description 9.2-21 III 9.2.6.3 Safety Evaluation 9.2-21 III 9.2.7 Reactor Makeup Water Sy:; tem 9.2-21 I 9.2.7.1 Design Bases 9.2-21 I 9.2.7.1.1 Safety Design Bases 9.2-21 I 9.2.7.1.2 Power Generation Design Basesi 9.2-23 I 9.2.7.2 System Description ,

9.2-23 I 9.2.7.2.1 General Description 9.2-23 I 9.2.7.2.2 Component Description 9.2-24 I 9.2.7.2.3 System Operation 9.2-24 I O 9.3 PROCESS AUXILIARIES 9.3-1 I 9.3.1 Compressed Air System 9.3-1 III 9.3.1.1 Design Bases 9.3-1 III 9.3.1.1.1 Safety Design Bases 9.3-1 III 9.3.1.1.2 Power Generation Design Bases 9.3-1 III 9.3.1.2 System Description 9.3-2* III 9.3.2 Process and Post Accident Sampling System 9.3-2 I O

WAPWR-AS v OCTOBER, 1986 5539e:1d

1

)

TABLE OF CDNTENTS (Continued)

Reference SAR Section Title Page Section Status g

9.3.2.1 Design Bases 9.3-2 I 9.3.2.1.1 Safoty Design Bases 9.3-2 I 9.3.2.1.2 Power Generation Design Bases 9.3-4 I 9.3.2.2 System Description 9.3-5 I 9.3.2.2.1 Normal Sampling Provisions 9.3-5 I 9.3.2.2.2 Post Accident Provisions 9.3-6 I 9.3.2.2.3 Equipment Description 9.3-8 I 9.3.2.3 Safety Evaluation 9.3-8 I 9.3.3 Equipment and Floor Drainage System 9.3-9 I 9.3.3.1 Design Bases 9.3-9 I 9.3.3.1.1 Safety Design Bases 9.3-9 I 9.3.3.1.2 Power Generation Design Bases 9.3-15 I 9.3.3.2 General Description 9.3-16 I 9.3.3.2.1 System Description 9.3-16 I 9.3.3.2.2 Component Description 9.3-17 I 9.3.3.3 Safety Evaluation 9.3-19 I 9.3.4 Chemical and Volume Control System 9.3-20 I 9.3.4.1 Design Bases 9.3-22 I 9.3.4.1.1 Safety Design Bases 9.3-22 I 9.3.4.1.2 Power Generation Design Bases 9.3-23 1 9.3.4.2 9.3.4.2.1

System Description

General Description 9.3-24 9.3-24 I

I h

9.3.4.2.1.1 Charging, Letdown, and RCP Seal Injection 9.3-24 I 9.3.4.2.1.2 Chemical Control, Purification, and Makeup 9.3-27 I Functions 9.3.4.2.2 Equipment Design Basis and Description 9.3-31' I 9.3.4.2.2.1 Pumps 9.3-31 I O

WAPWR-AS vi OCTOBER, 1986 5539e:1d

TABLE OF CONTENTS (Continued)

Reference l SAR Section Section Title P_ge Status 9.3.4.2.2.2 Heat Exchangers 9.3-32 I 9.3.4.2.2.3 Tanks 9.3-33 I 9.3.4.2.2.4 Demineralizers 9.3-35 I 9.3.4.2.2.5 Orifices 9.3-36 I 9.3.4.2.2.6 Filters 9.3-36 I 9.3.5 Baron Recycle System 9.3-37 I 9.3.5.1 Design Bases 9.3-39 I ,

9.3.5.1.1 Safety Design Bases 9.3-39 I 9.3.5.1.2 Power Generation Design Bases 9.3-39 I l

9.3.5.2 System Description 9.3-40 I l 9.3.5.2.1 General Description 9.3-40 I 9.3.5.2.2 Component Descriptions 9.3-44 I 9.3.6 Chlorine Supply System 9.3-48 III i 9.3.6.1 Design Bases 9.3-48 III 9.3.6.1.1 Safety Design Bases 9.3-48 III 9.3.6.1.2 Power Generation Design Bases 9.3-48 III 9.3.6.2 System Description 9.3-49  !!!

9.4 AIR CONDITIONING, HEATING, COOLING AND 9.4-1 I VENTILATION 9.4.1 Control Equipment Area Ventilation Systems 9.4-1 I O 9.4.1.1 9.4.1.1.1 Design Bases Safety Design Bases 9.4-1 9.4-1 I

1 ,

9.4.1.2 System Description 9.4-2 I

9. 4.1. 2.1 General Description 9.4-2 I 9.4.1.2.2 Component Description 9.4-3 I 9.4.1.2.3 System Operation 9.4 I 9.4.1.3 Codes and Standards 9.4-6 I O WAPWR-AS vii OCTOBER, 1986 5539e:1d r

TABLE OF CONTENTS (Continued)

Reference SAR Section Title  %

Section Status g

9.4.1.4 Safety Evaluation 9.4-7 I 9.4.1.5 Inspection and Testing Requirements 9.4-8 I 9.4.1.6 Instrumentation Application 9.4-9 I 9.4.2 Reactor External Building Ventilation System 9.4-10 1 9.4.2.1 Design Bases 9.4-10 I 9.4.2.1.1 Safety Design Bases 9.4-10 I 9.4.2.1.2 Power Generation Design Bases 9.4-11 I 9.4.2.2 System Description 9.4-11 I 9.4.2.2.1 General Description 9.4-11 I 9.4.2.2.2 Component Description 9.4-12 I 9.4.2.2.3 System Operation 9.4-13 I 9.4.2.3 Codes and Standards 9.4-14 I 9.4.2.4 Safety Evaluation 9.4-15 I 9.4.2.5 Inspection and Testing Requirements 9.4-16 I 9.4.2.6 Instrumentation Application 9.4-17 I 9.4.3 Radwaste Building Ventilation System Design 9.4-17 III Criteria 9.4.4 Turbine Building Ventilation System Design 9.4-18 III Criteria '

9.4.5 Annulus Air Cleanup and feel Building 9.4-18 I Emergency Exhaust System 9.4.5.1 Design Bases 9.4-18 I 9.4.5.1.1 Safety Design Bases 9.4-18 I 9.4.5.2 System Description 9.4-19 I 9.4.5.2.1 General Description 9.4-19 I 9.4.5.2.2 Component Description 9.4-20 I 9.4.5.2.3 System Operation 9.4-20 I O

WAPWR-AS viii OCTOBER, 1986 5539e:1d

i

  • l l

\  !

TABLE OF CONTENTS (Continued) i Reference  ;

SAR Section Section Title  % Status 9.4.5.3 Codes and Standards 9.4-22 I 9.4.5.4 Safety Evaluation 9.4-22 I 9.4.5.5 Inspection and Testing Requirements 9.4-23 I 9.4.5.6 Instrumentation Application 9.4-24 I 9.1.6 Containment Cooling and Ventilation System 9.4-24 I 9.4.6.1 Design Bases 9.4-25 I 9.4.6.1.1 Safety Design Bases 9.4-25 I 9.4.6.1.2 Power Generation Design Bases 9.4-26 I  ;

9.4.6.2 System Description 9.4-26 I '

9.4.6.2.1 General Doncription 9.4-26 I  ;

9.4.6.2.2 Component Description 9.4-29 I 9.4.6.2.3 System Operation 9.4-30 I 9.4.6.3 Codes and Standards 9.4-31 I 9.4.6.4 Safety Evaluation 9.4-32 I 9.4.6.5 Inspection and Testing Requirements 9.4-32 I 9.4.6.6 Instrumentation Application 9.4-33 I 9.4.7 Diesel Generator Building Ventilation System 9.4-34 I 9.4.7.1 Design Bases 9.4-34 I -

9.4.7.2 System Description 9.4-34 I 9.4.7.2.1 General Description 9.4-34 I O 9.4.7.2.2 Component Description 9.4-35 I 9.4.7.2.3 System Operation 9.4-35 I 9.4.7.3 Codes and Standards 9.4-35 I 9.4.7.4 Safety Evaluation 9.4-36 I O 9.4.7.5 9.4.7.6 Inspection and Requirements Instrumentation Application 9.4-37 I i 9.4-37 I 9.4.8 Essential Service Water Pump Structure 9.4-38 III Ventilation System Design Criteria WAPWR-AS ix OCTOBER, 1986 5539e:1d

TABLE OF CONTENTS (Continued)

Reference SAR Section Title Page Section Status h

9.4.9 Plant Heating System Design Criteria 9.4-38 III 9.4.9.1 General Description 9.4-38 III 9.4.9.2 Design Criteria 9.4-39 III 9.4.10 Essential Chilled Water System 9.4-40 I 9.4.10.1 Design Bases 9.4-41 I 9.4.10.1.1 Safety Design Bases 9.4-41 I 9.4.10.2 System Description 9.4-41 I 9.4.10.2.1 General Description 9.4-41 I 9.4.10.2.2 Component Description 9.4-42 I 9.4.10.2.3 System Operation 9.4-42 I 9.4.10.3 Codes and Standards 9.4-43 I 9.4.10.4 Safety Evaluation 9.4-43 I 9.4.10.5 Inspection and Testing Requirements 9.4-44 I 9.4.10.6 Instrumentation Application 9.4-45 I 9.5 OTHER AUXILIARY SYSTEMS 9.5-1 III 9.5.1 Fire Protection System 9.5-1 III 9.5.1.1 Design Basis 9.5-1 III 9.5.1.2 Codes and Standards 9.5-5 III 9.5.1.3 Protection of Safe Shutdown Related 9.5-7 III Equipment 9.5.1.4 Fire Protection System and Feature 9.5-8 III Descriptions 9.5.1.4.1 Passive Fire Protection Features 9.5-8 III 9.5.1.4.2 Active Fire Protection Features 9.5-13 III 9.5.1.4.3 9.5.1.4.4 Support Systems Curbs and Drains 9.5-16 9.5-17 III

!!I h

9.5.1.4.5 Reactor Coolant Pump Oil Collection System 9.5-18 III

[

WAPWR-AS x OCTOBER, 1986 O

5539e:1d

{

TABLE OF CONTENTS (Continued)

Reference SAR O

Section Section Title h Status 9.5.1.4.6 Smoke Control 9.5-18 III l 9.5.1.4.7 Access / Egress 9.5-18 III 9.5.1.4.8 Construction Materials and Combustible 9.5-19  !!!

Contents 9.5.1.5 Interaction with Other Systems 9.5-19 III l 9.5.1.6 Preoperational Testing 9.5-20  !!! l 9.5.1.7 Administrative Controls. Quality Assurance, 9.5-22 III l Personnel Qualification and Training 9.5.1.8 Summary 9.5-31 III 9.5.2 Communication Systems 9.5-32 III 9.5.2.1 Design Bases 9.5-32 III 9.5.2.2 System Description 9.5-32  !!!

9.5.2.2.1 Telephone /Page System 9.5-32 Ill 9.5.2.2.2 PABX System 9.5-33  !!!

9.5.2.2.3 Sound-Powered System 9.5-34 III 9.5.2.2.4 System Operation Communication Stations 9.5-34  !!!

9.5.2.3 Inspection and Testing Requirements 9.5-35  !!!

9.5.3 Lighting Systems 9.5-35  !!!

9.5.3.1 Design Bases 9.5-35  !!!

9.5.3.1.1 Safety Design Bases 9.5-35 III O 9.5.3.1.2 Power Generation Design Bases 9.5-35 Ill 9.5.3.2 System Description 9.5-36  !!!

9.5.3.2.1 Normal Lighting System 9.5-36  !!!

9.5.3.2.2 Essential Lighting System 9.5-36  !!!

O 9.5.3.2.3 9.5.3.2.4 Emergency Lighting System Exit Lighting System 9.5-37 9.5-38 III 9.5.3.3 Failure Analysis 9.5-38  !!!

9.5.3.4 Test and Inspections 9.5-39  !!!

WAPWR-AS xi OCTOBER, 1986 5539e:1d

TABLE OF CONTENTS (Continued)

Reference SAR Section Section Title Pace Status 9.5.4 Emergency Diesel Engine Fuel Oil Storage 9.5-39 III and Transfer System 9.5.4.1 Design Bases 9.5-39 III 9.5.4.1.1 Safety Design Bases 9.5-39 III 9.5.4.1.2 Power Generation Design Bases 9.5-40 III 9.5.4.2 System Description 9.5-41 III 9.5.4.3 Safety Evaluation 9.5-41 III 9.5.5 Emergency Diesel Engine Cooling Water System 9.5-41 III 9.5.5.1 Design Bases 9.5-41 III 9.5.5.1.1 Safety Design Bases 9.5-41 III 9.5.5.1.2 9.5.5.2 Power Generation Design Bases

System Description

9.5-42 9.5-42 III III g

9.5.5.3 Safety Evaluation 9.5-43 III 9.5.6 Emergency Diesel Engine Starting System 9.5-43 III 9.5.6.1 Design Bases 9.5-43 III 9.5.6.1.1 Safety Design Bases 9.5-43 III 9.5.6.1.2 Power Generation Design Bases 9.5-44 III 9.5.6.2 System Description 9.5-44 III 9.5.6.3 Safety Evaluation 9.5-45 III 9.5.7 Emergency Diesel Engine Lubrication System 9.5-45 III 9.5.7.1 Design Bases 9.5-45 I!!

9.5.7.1.1 Safety Design Bases 9.5-45 III 9.5.7.1.2 Power Generation Design Bases 9.5-46 III 9.5.7.2 System Description 9.5-46 III 9.5.7.3 Safety Evaluation 9.5-47 III 9.5.8 Emergency Diesel Engine Combustion Air Intake 9.5-47 III and Exhaust System O

WAPWR-AS xii OCTOBER, 1986 5539e:1d

U 4

] TABLE OF CONTENTS (Continued)

Reference O

SAR Section Section Title Page Status 9.5.8.1 Design Bases 9.5-47 III 9.5.8.1.1 Safety Design Bases 9.5-48 III 9.5.8.1.2 Power Generation Design Bases 9.5-48 III 9.5.8.2 System Description 9.5-48 III 9.5.8.3 Safety Evaluation 9.5-48 III I 10.0 STEAM AND POWER CONVERSION SYSTEM 10.0-1 NA 11.0 RADI0 ACTIVE WASTE MANAGEMENT 11.0-1 NA 12.0 RADIATION PROTECTION 12.0-1 NA 13.0 CONDUCT OF OPERATIONS 13.0-1 NA 14.0 INITIAL TEST PROGRAM 14.0-1 NA 15.0 ACCIDENT ANALYSES 15.0-1 NA 16.0 TECHNICAL SPECIFICATIONS 16.0-1 NA 17.0 QUALITY ASSURANCE 17.0-1 1 17.1 QUALITY ASSURANCE DURING DESIGN AND 17.0-1 I CONSTRUCTION l 17.1.1 References 17.0-1 I.

18.0 HUMAN FACTORS ENGINEERING 18.0-1 NA O

!O

!O i

i WAPWR-AS xiii OCTOBER, 1986

5539e
1d

_ . - - - , _ . - . - _ _ . . . _ _ - _ - _ _ . _ - - . _ _ ..-__) .

TABLE OF CONTENTS (Continued)

KEY TO " REFERENCE SAR SECTION STATUS" COLUMN:

Category 1 Those sections which are complete and for which no additional information is to be provided for the PDA application.

Category II Those sections which are complete insofar as providing material relevant to this system module but for which additional information will be provided in support of subsequent modules.

Category III Those sections for which information on interfacing systems will be provided at a later date.

S Those sections for which categorization is not applicable. Only the section titles are included for clarity.

O O

WAPWR-AS xiv OCTOBER, 1986 5539e:1d

4 TABLE OF CONTENTS (Continued)

LIST OF TABLES Number Title Pace 1.6-1 Material Incorporated by Reference 1.6-2 1.8-1 Standard Rev; i Plan Deviations 1.8-2 9.1-1 New Fuel Storage Design Data 9.1-57 9.1-2 Spent Fuel Storage Design Data 9.1-58 9.1.3 Spent Fuel Pit Cooling System - Failure Mode and 9.1-59 Effects Analyses 9.1-4 Spent Fuel Cask Bridge Crane and Polar Crane Data 9.1-61 9.2-1 Essential Service Water System - Flow versus 9.2-26 Operation Mode 9.2-2 Component Cooling Water System - Flows and Heat Loads 9.2-27 9.2-3 Component Cooling Water System - Failure Mode 9.2-31 f and Effects Analysis 9.2-4 Principal Reactor Makeup Water System - Equipment 9.2-43 Parameters 9.3-1 Sampling System - Principal Equipment Parameters 9.3-50 9.3-2 Post Accident Sampling System - Failure Modes 9.3-51 and Effects Analysis 9.3-3 Chemical and Volume Control - System Parameters 9.3-57 9.3-4 Chemical and Volume Control System - Principal 9.3-58 Component Data Summary 9.3-5 System Parameters 9.3-67 Os 9.3-6 Equipment Design Parameters 9.3-68 9.4-1 Main Control Room Air Handling System - Single 9.4-46 Active Failure Analysis 9.4-2 Switchgear Room Air Handling System - Single 9.4-48 Active Failure Analysis 9.4-3 Reactor External Building Ventilation System - Single 9.4-49 Active Failure Analysis O

WAPWR-AS xv OCTOBER, 1986 5539e:1d

TABLE OF CONTENTS (Continued)

Oll LIST OF TABLES i Number Title Page 9.4-4 Annulus Air Cleanup and Fuel Building Emergency 9.4-52 Exhaust - Single Active Failure Analysis 9.4-5 Diesel Generator Building Ventilation System - Single 9.4-53 Active Failure Analysis 9.4-6 Essential Chilled Water System - Single Active 9.4-55 Failure Analysis 9.5-1 Communication Equipment and Locations Available for 9.5-1 Safe Shutdown O

l l

l l

O l

l O

l WAPWR-AS xvi OCTOBER, 1986 5539e:1d

TABLE OF CONTENTS (Continued)

LIST OF FIGURES O

V Number Title 9.1-1 Westinghouse APWR Spent Fuel Pit Cooling System (EFD) 9.1-2 Westinghouse APWR Spent Fuel Pit Cooling System (Purification) (EFD) 9.1-3 Westinghouse APWR Refueling Machine 9.1-4 Westinghouse APWR Fuel Handling Machine 9.1-5 Westinghouse APWR New Fuel Elevator 9.1-6 Westinghouse APWR Fuel Transfer System 9.1-7 Westinghouse APWR New Fuel Handling Tool 9.2-1 Westinghouse APWR Component Cooling Water System (EFD) 9.2-2 Westinghouse APWR Reactor Makeup Water System (EFD) 9.3-1 Westinghouse APWR Process and Post Accident Sampling System (EFD) 9.3-2 Westinghouse APWR Chemical and Volume Control System (EFD) 9.3-3 Westinghouse APWR Boron Recycle System (EFD) 9.4-1 (Sn. 1) Main Control Room Air Handling System 9.4-1 (Sh. 2) Main Control Room Air ilandling System - Normal Operation "A" Train Active 9.4-1 (Sh. 3) Main Control Room Air Handling System - Normal Operation "B" Train Active 9.4-1 (Sh. 4) Main Control Room Air Handling System - Emergency w Recirculation Condition "A" Train Active 9.4-1 (Sh. 5) Main Control Room Air Handling System - Emergency Recirculation Condition "B" Train Active 9.4-1 (Sh. 6) Main Control Room Air Handling System - Emergency Makeup Condition "A" Train Active d 9.4-1 (Sh. 7) Main Control Room Air Handling System - Emergency Makeup

' Condition "B" Train Active O

WAPWR-AS xvii OCTOBER, 1986 5539e:1d

TABLE OF CONTENTS (Continued)

LIST OF FIGURES Number Title 9.4-2 "A" Switchgear Room Air Handling System 9.4-3 "B" Switchgear Room Air Handling System 9.4-4 Reactor External Building Ventilation System g 9.4-5 Reactor External Building Safeguard Component Area Cooling W System 9.4-6 Reactor External Building CCW Pump Room Cooling System Charging Pump Room Cooling System 9.4-7 Reactor External Building EFW Pump Room and Main Steam Piping Room Ventilation 9.4-8 Annulus Air Clean-up and Fuel Building Emergency Exhaust System 9.4-9 (Sh. 1) Annulus Air Clean-up and Fuel Building Emergency Exhaust System - Annulus Draw Down Mode 9.4-9 (Sh. 2) Annulus Air Clean-up and Fuel Building Emergency Exhaust System - Annulus Recirculation Mode 9.4-10 Annulus Air Clean-up and Fuel Building Emergency Exhaust System - Fuel Building Exhaust Mode 9.4-11 Containment Cooling and Ventilation System 9.4-12 Diesel Generator Room Ventilation System 9.4-13 Essential Chilled Water System z i

l 0-l

O l

WAPWR-AS xviii OCTOBER, 1986 5539e:1d