_ .- - . - - -. - - . - - . - ~ - - - - - - - - - -
1 E0P: TITLE:
LOSS OF ALL AC POWER RECOVERY WITH SI REV: 11
.ECA-0.2 REQUIRED PAGE 1 of 9 O
(_f ROCHESTER GAS AND ELECTRIC CORPORATION GINNA STATION CONTROLLED COPY NUMBER b e
RESPONSIBLE)hANAGER j JR -H4f EFFECTIVE DATE CATEGORY 1.0 REVIEWED BY:
U 9812210279 981214 I t-
' PDR ADOCK 05000244, 1 P PDR Q _ _
. .. ~ - . . . - _ . . - . -
. - . . . . . . . - _ . . ~ . . ~ - . ~ . - . ~ . . . - . . . .
4 l , E0P: TITLE:
l LOSS OF ALL AC POWER RECOVERY WITH SI REV: 11 ECA-0.2 REQUIRED i
PAGE 2 of 9 IO lJ A. PURPOSE - This procedure provides actions to use engineered safeguards systems to recover plant conditions following restoration of AC emergency power.
B. ENTRY CONDITIONS / SYMPTOMS
- 1. ENTRY CONDITIONS - This procedure is entered from:
l a. ECA-0.0, LOSS OF ALL AC POWER, when AC emergency l power is restored and SI is required.
l b. ECA-0.1, LOSS OF ALL AC POWER RECOVERY WITHOUT SI REQUIRED, if SI is required.
I h
l O
l l
l
E0P: TITLE:
LOSS OF ALL AC POWER RECOVERY WITH SI REV: 11 ECA-0*2 4
REQUIRED TAGE 3 of 9 G
V -
STEP -
ACTION / EXPECTED RESPONSE RESPONSENOTUBTi.1NEDl NOTE: o CSFSTs should be monitored for information only. FR procedures
- should not be implemented prior to completion of Step 10.
l o Adverse CNMT values should be used whenever CNMT pressure is greater than 4 psig or CNMT radiation is greater than 10+05 R/hr.
1 Reset SI 2 Check RCP CCW Isolation Status:
- a. CCW pumps - BOTH PUMPS OFF a. Go to Step 3.
l b. RCP CCW return valves - CLOSED b. Manually close valves as l necessary:
i e MOV-759A i' . MOV-759B o RCP CCW thermal barrier j outlet valves l
- A0V-754B l
l -OR-l' o RCP CCW supply valves e MOV-749A ;
e MOV-749B
- i i i 3 Check RWST Level - GREATER Co to ES-1.3. TRANSFEP. TO COLD LEG THAN 28% RECIRCULATION, Step 1.
l l
l l
I i
l a
LOP: 'ilI LE:
LOSS OF ALL AC' POWER RECOVERY WITH SI REV: 11 ECA-0.2 4
REQUIRED PAGE 4 of 9 O -
STEP -
ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED F_QIB: SI actuation to establish safeguards valve alignment is not recommended.
4 Manually Align SI And RHR Pumps To Establish SI Injection:
- OPEN suction valve from RWST open.
. MOV-825A e MOV-825A
= MOV-825B e MOV-825B
- b. Verify SI pump C discharge b. Manually open valves as valves - OPEN necessary.
. MOV-871A e MOV-871B
- c. RHR pump discharge to Rx vessel c. Ensure at least one deluge valve O
deluge - OPEN open.
. MOV-852A e MOV-852A e MOV-852B e MOV-852B O _
E0P: TITLE:
LOSS OF ALL AC POWER RECOVERY WITH SI REV: 11 ECA-0.2 REQUIRED PAGE 5 of 9 p .
V STEP -
ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED CAUTION THE LOADS PLACED ON THE ENERGIZED AC EMERGENCY BUS SHOULD NOT EXCEED THE CAPACITY OF THE POWER SOURCE.
5 Manually Load Following -
Safeguards Equipment On AC Emergency Bus: 1
- a. Start all SI pumps a. Perform the following:
- 1) Start available SI pumps.
o H SI pump A M available. THEN ensure MOV-871B closed, o H SI pump B M available. THEN ensure MOV-871A closed,
o Pressure - GREATER THAN 250 psig [465 psig adverse CNMT) o Pressure - STABLE OR INCREASING
- c. Place RHR pump switches in AUTO
- d. Start all available CNMT RECIRC fans
-a _ L z_ - . . . . ._ , A -...A __ ._.A ., .m.R _-. h E0P: TITLE: l LOSS OF ALL AC POWER RECOVERY WITH SI REV: 11 j 4
ECA-0.2 REQUIRED l PAGE 6 of 9
('~\ ,
I (_ /
STEP --
ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED i
l CAUTION l
o IF CST LEVEL DECREASES TO LESS TRAN 5 FEET. THEN ALTERNATE WATER SOURCES FOR AFW PUMPS WILL BE NECESSARY (REFER TO ER-AFW.I. ALTERNATE WATER SUPPLY TO AFW PUMPS).
I o IF S/G NR LEVEL DECREASES TO LESS THAN 5% [25% ADVERSE CNMT] AND FEED FLOW
' l IS LESS THAN 200 GPM, THEN THE MDAFW PUMPS SHOULD BE MANUALLY LOADED ON AC l EMERGENCY BUS TO SUPPLY WATER TO THE S/G(S).
4 l
NOTE: o If MDAFW pump operation is not required, pump switches should be l maintained in PULL-STOP to prevent automatic start.
o TDAFW pump flow control valves fail open on loss of IA.
- 6 Monitor Intact S/G Levels:
fx i() a. Narrow range level - GREATER THAN 5% [25% adverse CNMT]
- a. Maintain total feed flow greater than 200 gpm until narrow range level greater than 5% [25%
adverse CNMT] in at least one S/G.
IE feed flow less than 200 gpm, THEN perform the following:
- 1) Verify MDAFW pump discharge valve to intact S/G(s) open.
. S/G A, MOV-4007 e S/G B, MOV-4008
- 2) Manually start MDAFW pumps as necessary (228 KW).
- b. Control feed flow to maintain narrow range level between 17%
l [25% adverse CNMT] and 50%
,T U
f i
LOP: TITLE:
LOSS OF ALL AC POWER RECOVERY WITH SI REV: 11
. ECA-0.2 REQUIRED PAGE 7 of 9 b'i l O l STEP -
ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED 1
l l 7 Verify CI And CVI:
1
- a. CI and CVI annunciators - LIT a. Depress manual CI pushbutton.
- Annunciator A-26. CNMT '
ISOIATION l
- Annunciator A-25. CONTAINMENT l VENTILATION ISOLATION l i
- lights - BRIGHT valves. IE valves can EI be '
verified closed by MCB indication THEN dispatch A0 to locally close valves (Refer to Attachment CI/CVI).
- c. CNMT RECIRC fan coolers SW c. Dispatch A0 to locally fail apen outlet valve status lights - valves.
BRIGHT i e A0V-4561 e A0V-4562 i
1 b[h I
LOP: ilTLE:
LOSS OF ALL AC POWER RECOVERY WITH SI RW: 11 ECA-0.2 4
REQUIRED PAGE 8 of 9
.O V
STEP -
ACTION / EXPECTED RESPONSE RESPONSE NOT OBTAINED 8 Verify CNMT Spray Not IE CNMT pressure is less than 28 Required: psig. THEN perform the following:
o Annunciator A-27. CNMT SPRAY - a. Reset CNMT spray.
EXTINGUISHED
- b. Place CNMT spray pump dinharge o CNMT pressure - LESS THAN 28 PSIG valve switches to CLOSE to deenergize open contactor.
IF NOT, THEN perform the following:
- a. Depress manual CNMT spray pushbuttons (2 of 2).
- b. Ensure CNMT spray pump discharge valves open.
o CNMT spray pump A:
- MOV-860A e MOV-860B o CNMT spray pump B:
- MOV-8600 e MOV-860D c'. Ensure NaOH tank outlet valves open.
- d. Start both CNMT spray pumps.
- e. Go to step 10.
O O
(
. . - . _ . - . . . . _ . ~ . . - . _ - _ - . . . . . . - . . . _ _ . . .
se
- E0P
- TITLE:
LOSS OF ALL AC POWER RECOVERY WITH SI REV: 11 ECA-0.2 i REQUIRED PAGE 9 of 9 0 -
STEP -
ACTION / EXPECTED RESPONSE -<
RESPONSE NOT OBTAINED 9 Place CNMT Spray Pumps In AUTO 10 Check RCP Seal Injection Locally close valves before Needle Valves - CLOSED starting charging pump.
e V-300A
= V-300B HQI_E: FR procedures may now be implemented as necessary.
11 Go to E-1, LOSS OF REACTOR OR SECONDAR'I COOLANT, Step 1
-END-O i
l a
p 4
I