(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Letter Sequence Other |
---|
EPID:L-2018-LLA-0252, Package: Application for Amendment No. 8 to the Model No. Magnastor Storage Cask - RAI (Approved, Closed) |
|
MONTHYEARML18299A0082018-10-25025 October 2018 Letter to W. Fowler Receipt of Test Data for Thermal Performance Test for Magnastor Storage System for Certificate of Compliance No. 1031 - Acknowledgement Letter Project stage: Other ML19056A0582019-02-22022 February 2019 Enclosure 1: Non-Proprietary RAI (Letter to W. Fowler Application for Amendment No. 8 to the Model No. Magnastor Storage Cask - Request for Additional Information) Project stage: RAI ML19056A0562019-02-22022 February 2019 Package: Application for Amendment No. 8 to the Model No. Magnastor Storage Cask - RAI Project stage: Request ML19056A0572019-02-22022 February 2019 Letter to W. Fowler Application for Amendment No. 8 to the Model No. Magnastor Storage Cask - Request for Additional Information Project stage: RAI ML19135A6932019-05-15015 May 2019 Notice of Closed Meeting with NAC International to Discuss Proprietary Thermal Analysis Details for Amendment No. 8 to the Model No. Magnastor Storage Cask Project stage: Meeting ML20036E0822020-02-20020 February 2020 Final Certificate of Compliance for Spent Fuel Storage Casks Amendment No. 8 Project stage: Other ML20036E0812020-02-20020 February 2020 Final CoC 1031 A8 TS Appendix B Project stage: Other ML20036E0802020-02-20020 February 2020 Final CoC 1031 A8 Technical Specifications and Design Features Appendix a Project stage: Other ML20036E0842020-02-20020 February 2020 Transmittal Letter Magnastor Amendment 8 Project stage: Other ML20036E0832020-02-20020 February 2020 Safety Evaluation Report, Amendment No. 8 Project stage: Approval 2019-02-22
[Table View] |
|
---|
Category:Letter
MONTHYEARML24008A2482024-01-0808 January 2024 NAC International, Response to Apparent Violations (a and B) in NRC Inspection Report 72-1031/2023-201; EA-2023-069 ML23283A2382023-12-0707 December 2023 NAC International, Inc. - U.S. Nuclear Regulatory Commission Inspection Report 72-1031/2023-201 ML23250A3242023-09-12012 September 2023 1. Transmittal Letter Magnastor Issuance of Amendment Nos 11 and 12 and Revision of Amendment Nos 0 Through 9 ML23166B0832023-07-0505 July 2023 Independence Spent Fuel Storage Installation - Issuance of Exemption ML23143A3912023-05-23023 May 2023 Independent Spent Fuel Storage Installation - Request for Exemption from NAC-MAGNASTOR Certificate of Compliance 72-1031 - Cask Lid Batch 3 Design Requirements ML23074A2522023-03-29029 March 2023 Application for Amendment No. 13 to the Model No. Magnastor Storage Cask Request for Additional Information ML23076A2272023-03-17017 March 2023 Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Transportable Storage Canister Identification Numbers AMZDFX165 and AMZDFX166 and Vertical Concrete Cask Identification Numbers ML23005A2572023-01-0505 January 2023 Request to Withdraw Administrative Controls for Adverse Weather Events During Operations from Magnastor Amendment 12 Supplement ML22349A4682022-12-19019 December 2022 Amendment No. 10 to Certificate of Compliance No. 1031 for the Magnastor Storage System ML22340A5902022-12-0808 December 2022 Acknowledgement Letter - Magnastor Amendment 13 ML22327A2252022-11-23023 November 2022 NAC International - Magnastor Cask System Users CoC Amendment 12 Supplement and Intent to Adopt Letters ML22321A2682022-11-17017 November 2022 Supplement to the Submission of an Amendment Request for the NAC International Magnastor Cask System, Amendment No. 13 ML22308A1942022-11-0909 November 2022 NAC International, Inc. - U.S. Nuclear Regulatory Commission Report No. 72-1031/2022-201 ML22287A0382022-10-13013 October 2022 Supplement to the Submission of an Amendment Request for the NAC International Magnastor Cask System, Amendment No. 13 ML22257A2562022-09-14014 September 2022 Registration of Dry Spent Fuel Transportable Storage Canisters Identification Numbers AMZDFX170 and AMZDFX174 and Vertical Concrete Cask Identification Numbers AMZDNE170 and AMZDNE174 ML22230D0802022-08-18018 August 2022 Independent Spent Fuel Storage Installation - Registration of Dry Spent Fuel Transportable Storage Container ML22216A1102022-08-0404 August 2022 Magnastor Cask System Users CoC Amendments 0 Thru 9 Intent to Adopt Letters ML22208A0782022-07-27027 July 2022 Registration of Use of Cask to Store Spent Fuel ML22196A0232022-07-15015 July 2022 Submittal of Supplemental Information to the Nrc'S Request for Additional Information for the NAC International Magnastor Cask System Amendment No. 11 ML22201A0662022-07-13013 July 2022 NAC International, Inc., Submittal of Data Disk for the Magnastor Cask System, Amendment No. 13 ML22194A9082022-07-13013 July 2022 NAC, Submittal of an Amendment Request for the NAC International Magnastor Cask System, Amendment No. 13 ML22111A3572022-05-16016 May 2022 Letter Issuing Exemption to Catawba ML22111A3112022-05-16016 May 2022 Letter Issuing Exemption to McGuire ML22111A2842022-05-13013 May 2022 Independence Spent Fuel Storage Installation - Issuance of Exemption ML22110A1112022-05-13013 May 2022 Letter Issuing Exemption to TMI-1 ML22125A1532022-05-0505 May 2022 Registration of Use of Casks to Store Spent Fuel ML22118B1622022-04-28028 April 2022 Request for Exemption from NAC-MAGNASTOR Certificate of Compliance 72-1031 - Cask Lid Design Requirements - Supplement RS-22-062, Supplemental Information to Exemption to the Requirements of Certificate of Compliance No. 1031 for the NAC Magnastor Storage System2022-04-26026 April 2022 Supplemental Information to Exemption to the Requirements of Certificate of Compliance No. 1031 for the NAC Magnastor Storage System ML22108A1972022-04-18018 April 2022 RAI Response to Nac'S Amendment Request for the NAC International Magnastor Cask System Amendment No. 12 ML22095A1012022-04-12012 April 2022 Application for Amendment No. 12 to the Model No. Magnastor Storage Cask - Request for Additional Information ML22101A0042022-04-0707 April 2022 Registration of Use of Casks to Store Spent Fuel ML22090A0982022-03-31031 March 2022 Independent Spent Fuel Storage Installation - Request for Exemption from NAC-MAGNASTOR Certificate of Compliance 72-1031 - Cask Lid Design Requirements ML22082A2762022-03-23023 March 2022 Independent Spent Fuel Storage Installation - Registration of Dry Spent Fuel Transportable Storage Canister Identification Numbers AMZDFX164 and AMZDFX168 and Vertical Concrete Cask Identification Numbers ML22077A7692022-03-18018 March 2022 Supplement to Nac'S Amendment Request for the NAC International Magnastor Cask System Amendment No. 12 ML22024A3742022-01-24024 January 2022 Submission of an Amendment Requestfor the NAC International Magnastor Cask System Amendment No. 12 ML22018A0592022-01-11011 January 2022 NAC International, Inc., Submittal of Supplemental Information to the Nrc'S Request for Additional Information for the NAC International Magnastor Cask System Amendment No.11 ML21277A0452021-09-24024 September 2021 Submittal of Final Safety Analysis Report (Fsar), Revision 12, for the NAC Magnastor Cask System ML21251A5302021-09-0202 September 2021 Supplemental Responses to the NRCs Request for Additional Information for the NAC International Magnastor Cask System Amendment No. 10 ML21242A0502021-08-23023 August 2021 Submission of Responses to the Nrc'S Request for Additional Information for the NAC International Magnastor Cask System Amendment No. 11 ML21174A0732021-07-12012 July 2021 Application for Amendment No. 10 to the Model No. Magnastor Storage Cask - Second Request for Additional Information ML21183A1872021-07-0202 July 2021 Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Transportable Storage Canister Identification Number AMZDFX163 and Vertical Concrete Cask Identification Number AMZDNE163 ML21102A0872021-05-0707 May 2021 NRC Review of NAC Internationals Response Letter to Inspection Report 07201015/2020201 Notice of Violation EA-20-066; and Response to Disputed Notice of Violation ML21118A0432021-04-20020 April 2021 NAC International, Inc., Supplemental Responses to the NRCs Request for Additional Information for the Cask System Amendment No. 10 ML21078A5142021-03-19019 March 2021 Independent Spent Fuel Storage Installation - Registration of Dry Spent Fuel Transportable Storage Canister Identification Number AMZDFX161 and Vertical Concrete Cask Identification Number AMZDNE161 ML21047A1992021-02-26026 February 2021 Application for Amendment No. 11 to the Model No. Magnastor Storage Cask - First Request for Additional Information ML21067A0422021-02-25025 February 2021 Submission of Responses to the Nrc'S Request for Additional Information for the NAC International Magnastor Cask System Amendment No. 10 ML21050A3262021-02-19019 February 2021 Independent Spent Fuel Storage Installation - Registration of Dry Spent Fuel Transportable Storage Canister ML21036A0372021-01-29029 January 2021 NAC International Reply to Notice of Violation (EA-20-066), January 29, 2021 (Docket Nos.: 72-1015, 72-1025, 72-1031) ML20351A4512020-12-16016 December 2020 License Amendment Request, Proposed Revision to License Conditions and Permanently Defueled Technical Specifications for Permanent Removal of Irradiated Fuel from the Spent Fuel Pool (ISFSI-Only Tech Specs) ML20307A1172020-11-10010 November 2020 Transmittal Letter - Amendment No. 9 to Certificate of Compliance No. 1031 for Magnastor Storage System 2024-01-08
[Table view] |
Text
February 20, 2020 Mr. Wren Fowler, Director Licensing, Engineering NAC International 3930 East Jones Bridge Road, Suite 200 Norcross, GA 30092
SUBJECT:
AMENDMENT NO. 8 TO CERTIFICATE OF COMPLIANCE NO. 1031 FOR THE MAGNASTOR STORAGE SYSTEM
Dear Mr. Fowler:
As requested by your application dated September 12, 2018 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML18257A079), as supplemented on November 11, 2018 (ADAMS Accession No. ML18331A180), June 14, 2019 (ADAMS Accession No.ML19171A269), and July 16, 2019 (ADAMS Accession No. ML19199A151),
enclosed is Amendment No. 8 to the Certificate of Compliance No. 1031 for the MAGNASTOR storage system. This amended certificate issued by the U.S. Nuclear Regulatory Commission (NRC) constitutes the approval and conditions for use of the MAGNASTOR storage system for storage of spent nuclear fuel under the general license provisions of Title 10 of the Code of Federal Regulations (10 CFR), Part 72, Subparts K and L. The amendment deletes Technical Specification A5.6 and revises the maximum pellet diameter in TS, Appendix B, Table B2-3 from 0.325 inches to 0.3255 inches for the CE16H1 hybrid fuel assembly.
As stated in the Federal Register (85 FR 1096, January 9, 2020), the effective date of this certificate is March 24, 2020. The NRC safety evaluation report for this amended certificate (including the Technical Specifications) is enclosed. If you have any questions regarding this amended certificate, please contact Bernard White at (301) 415-6577.
Sincerely,
/RA/
Daniel I. Doyle, Acing Chief Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No.: 72-1031
Enclosures:
- 1. Certificate of Compliance No. 1031
- 2. Technical Specifications
- 3. Final Safety Evaluation Report
W. Fowler
SUBJECT:
AMENDMENT NO. 8 TO CERTIFICATE OF COMPLIANCE NO. 1031 FOR THE MAGNASTOR STORAGE SYSTEM DATED: February 20, 2020 Closes EPID No. L-2018-LLA-0252 Distribution:
DFM r/f D. Marcano, NMSS J. Solis, NMSS A. Barto, NMSS ADAMS Package Number: ML20036E079
- via email OFFICE DSFM DSFM DSFM NAME BWhite WWheatley DDoyle DATE 2/6/20 2/18/20 2/20/20 OFFICIAL RECORD COPY