MONTHYEARML18299A0082018-10-25025 October 2018 Letter to W. Fowler Receipt of Test Data for Thermal Performance Test for Magnastor Storage System for Certificate of Compliance No. 1031 - Acknowledgement Letter Project stage: Other ML19056A0582019-02-22022 February 2019 Enclosure 1: Non-Proprietary RAI (Letter to W. Fowler Application for Amendment No. 8 to the Model No. Magnastor Storage Cask - Request for Additional Information) Project stage: RAI ML19056A0562019-02-22022 February 2019 Package: Application for Amendment No. 8 to the Model No. Magnastor Storage Cask - RAI Project stage: Request ML19056A0572019-02-22022 February 2019 Letter to W. Fowler Application for Amendment No. 8 to the Model No. Magnastor Storage Cask - Request for Additional Information Project stage: RAI ML19135A6932019-05-15015 May 2019 Notice of Closed Meeting with NAC International to Discuss Proprietary Thermal Analysis Details for Amendment No. 8 to the Model No. Magnastor Storage Cask Project stage: Meeting ML20036E0822020-02-20020 February 2020 Final Certificate of Compliance for Spent Fuel Storage Casks Amendment No. 8 Project stage: Other ML20036E0812020-02-20020 February 2020 Final CoC 1031 A8 TS Appendix B Project stage: Other ML20036E0802020-02-20020 February 2020 Final CoC 1031 A8 Technical Specifications and Design Features Appendix a Project stage: Other ML20036E0842020-02-20020 February 2020 Transmittal Letter Magnastor Amendment 8 Project stage: Other ML20036E0832020-02-20020 February 2020 Safety Evaluation Report, Amendment No. 8 Project stage: Approval 2019-02-22
[Table View] |
|
---|
Category:Request for Additional Information (RAI)
MONTHYEARML24226B2182024-09-0606 September 2024 Cover Letter - Request for Additional Information for Review of the Magnastor Storage System Amendment No. 15, Certificate of Compliance No. 1031 ML24226B2202024-09-0606 September 2024 Enclosure - Request for Additional Information - Magnastor Amendment 15 - Non-Proprietary RAIs ML24120A0362024-05-0707 May 2024 Application for Amendment No. 14 to the Model No. Magnastor Storage Cask - Request for Additional Information ML23074A2522023-03-29029 March 2023 Application for Amendment No. 13 to the Model No. Magnastor Storage Cask – Request for Additional Information ML22095A1022022-04-13013 April 2022 Enclosure 1 Magnastor Amendment 12 RAI 1 Non-Proprietary ML21174A0742021-07-12012 July 2021 Request for Additional Information Magnastor Storage System Amendment No. 10 ML21047A2012021-02-26026 February 2021 Non-proprietary Request for Additional Information Enclosure ML21047A1992021-02-26026 February 2021 Application for Amendment No. 11 to the Model No. Magnastor Storage Cask - First Request for Additional Information ML20258A1612020-10-0808 October 2020 Magnastor Amd 10 non-proprietary RAI Enclosure ML20064D4672020-03-0404 March 2020 Application for Amendment No. 10 to the Model No. Magnastor Storage Cask - Request for Supplemental Information ML19354B6372020-01-0707 January 2020 Exemption Request for NAC Magnastor Cask Loaded to Incorrect Helium Backfill Density Request for Additional Information ML20086J5522019-10-0909 October 2019 Request for Additional Information - Enclosure ML19056A0582019-02-22022 February 2019 Enclosure 1: Non-Proprietary RAI (Letter to W. Fowler Application for Amendment No. 8 to the Model No. Magnastor Storage Cask - Request for Additional Information) ML18032A4412018-02-0101 February 2018 Enclosure 1: Request for Additional Information (Non-Proprietary) (Letter to W. Fowler Application for Amendment No. 8 to the Model No. Magnastor Storage Cask-Request for Additional Information) 2024-09-06
[Table view] |
Text
Non-Proprietary Request for Additional Information Docket No. 72-1031 Certificate of Compliance No. 1031 Model No. MAGNASTOR Storage System By application dated September 12, 2018 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML18257A079), as supplemented on November 11, 2018 (ADAMS Accession No. ML18331A180), NAC International (NAC or the applicant) submitted an application, in accordance with Title 10 of the Code of Federal Regulations (10 CFR) Part 72, for Amendment No. 8 to Certificate of Compliance No. 1031 for the Model No. MAGNASTOR storage system. This request for additional information identifies information needed by the U.S. Nuclear Regulatory Commission staff in connection with its review of the application. The requested information is listed by chapter number and title in the applicants safety analysis report (SAR). The NRC staff used NUREG-1536, Standard Review Plan for Spent Fuel Dry Storage Systems at a General License Facility Final Report, in its review of the application.
Each question describes information needed by the staff for it to complete its review of the application and to determine whether the applicant has demonstrated compliance with regulatory requirements.
Thermal Evaluation
- 1. See Enclosure 2.
- 2. Verify that a two-dimensional (2-D) computational fluid dynamics (CFD) thermal model accurately captures the heat transfer characteristics of the test performed to validate MAGNASTOR thermal analysis.
[Proprietary information removed-See enclosure 2]
The certificate of compliance condition states, in part, that "The heat transfer characteristics and thermal performance of the MAGNASTOR SYSTEM will be validated by recorded mass flow measurements in the air flow cooling passages of the first system placed in service with a heat load equal to or greater than 30 kW. The analysis provided by the applicant does not appear to accomplish this. The applicant may need to develop a more detailed three-dimensional (3-D) model in order to accurately capture the heat transfer characteristics of the test designed for this specific purpose. When performing validation, solution verification (to obtain the discretization error), and uncertainty quantification studies the staff uses American Society of Mechanical Engineers (ASME) Verification and Validation (V&V) 20-2009 Standard for Verification and Validation in Computational Fluid Dynamics and Heat Transfer and NUREG-2152 Computational Fluid Dynamics Best Practice Guidelines for Dry Cask Applications.
The staff needs this information to confirm that the applicants thermal model adequately captures the heat transfer characteristics of the designed test to validate the MAGNASTOR thermal analysis, as required by the certificate of compliance.
This information is necessary to verify the requirements of 10 CFR 72.236(f), (l), and (m).
Enclosure 1