_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
wavue vuLa L46: 4s 6 as.. ve a i fr CONinOL ULOCK:[ ^ l l l l l [pLCASE PRINT ALL HCQUIRED INFC'17.1 AT:C7:
I, . 1 6 NAME * (CENSE EVENI LICENSF NOMuf f) T yg'[
vlLicl nl rl 3l 14 10 l 04-l 0l 0l 0l 0l 0l-l 0l 0l l4 l 1l1l1 l1 l l 0l 3l 1b T Y6*C 26 2G 30 31 32 CAltGOHY " 7PE 1 i DOCKET NUM0ER EVENT OAir .
hCONT l- l - l 7 U 57 lLl l0l5l0l-l0l3l0l2l l 0l 4l 2 l 7 l7 l7 l l0 REPOnf OatE l5 l1l8l7l7 b0 59 60 61 60 69 74 75 OL EVENT DESCniPTION O l 7 0D In Mode 1 ooe ration performing SP-110, regulating rod Group 6 exceeded its insertion l 03 l limit by 5% contraN to Technical Specification 3.1.3.6. Redundancy N/A. First Ot 7 11 D l U4 l occurrence of thh tvoe. The Groun was adiusted to within soecified limits in 12 j
@l 7 00 minutes. CD l
@l 7 09 (LER-7 7-44) 00 l
systru CAUSE CCP ENT COMPONCNT COOE CODE COMPOtJENT COCE SUPPLIER MANUFACTUAEA VOLATON Q lRlBl l Al 7 UD 10 11 lClRlDlRlVlEl 12 lN l [ Dj 1l5 l0 l l Nl 17 43 44 47 48 CAUSE DESCn!PTION 'b ,
90 l
' " Rod Group 6 moved out of its enveJope because of xenon buildup and having Group 7 fully l 00 hl
/ It 9 insertPd with sequence override in effect. Persohnel cautioned to monitor rod index l 7
% limits more closely.
l i ACuiv METHoo or STAtuG % POWER OTHER STATUS 06SCOVE4Y OISCOVEnY OESCRIPTON Q~ (Ej l 0l 8l 6l l N/A l W l N/A
/0 9 10 12 13 l
FOHM OF 44 46 46 00 ACIMtY CONirNT ,
fiftfAStu AMOUNT OF ACTMTY 1P
/ U W
D OF dCELE ASE l 10 N/A l l LOCATION OF AELEASE N/A l 11 44 45 60 PENS 0,NNEL EXPOSURES NUMBER TYPF DESCAIPTOrd 8 1010101 L:J
/ 00 l N/A l '
i 11 1P 13 GO PERSONNEL INJUHTES NUMiti n DESCIUPT ON
] l0l0l0l l N/A l
/ 09 11 12 00 1 Of tulle CONSI OULNCf G
@l
/ 0D N/A
- l 00 LOSS On OAMAGE TO FACILnY tveE ot sCimlCN .
8
/O9 LzJ l 10 N/A
_l 1
PUBLICITY 3l
/ 0D N/A l
00 OITIONAL FACTORS DT See at tached StipplciTntary Information 8002280 2 O .J !
. L'u I
" .m [
NAun 2,_z_s.temr t (LD niONe_ m su-4m l
\ ) SUPPLEMENTARY INFORMATION
%J
- 1. Report No: 50-302/77-44
- 2. Facility: Crystal River Unit #3
- 3. Report Date: 18 May 1977
- 4. Occurrence Date: 27 April 1977
- 5. Identification of occurrence:
Regulating rod insertion limits exceeded contrary to Technical Speci-fication 3.1.3.6.
- 6. Conditions Prior to Occurrence:
Mode 1 power operation. Power reduced to approximately 2108 MWT in ,
order to place Group 7 regulating rods in ful1 insertion during per- 3 formance of Reactor Protective System Functional Test (SP-110). f
- 7. Description of Occurrence:
At 1950 on 27 Apr111977 during the performance of SP-110, Group 6 regulating control rods moved out exceeding insertion limits by 5%.
The Group was adjusted to within limits by 2002, an elapsed time of U 12 minutes.
- 8. Designation of Apparent Cause of Occurrence:
Because of previous experience of Group 7 dropping into core (See LER-77-43), power was run back to allow full insertion of that group during performance of SP-110. Subsequent xenon buildup caused Group 6 to withdraw but, because of sequence override, Group 7. remained fully in-serted. Operator failed to observe that rod index limits were exceeded.
- 9. Analysis of Occurrence:
There were no safety implications with this occurrence.
- 10. Corrective Action:
Operations personnel have been instructed to monitor the rod index limits more closely,
- 11. Failure Data:
This was the first occurrence of this type.
s l
l x_ /
l l
l i
1
! ._._