ML16054A709
ML16054A709 | |
Person / Time | |
---|---|
Site: | Technical Specifications Task Force |
Issue date: | 02/11/2016 |
From: | Mann B Excel Services Corp |
To: | Michelle Honcharik Licensing Processes Branch (DPR) |
Honcharik M | |
Shared Package | |
ML16054A498 | List: |
References | |
TSTF-425 | |
Download: ML16054A709 (2) | |
Text
From: Brian Mann <Brian.Mann@excelservices.com>
Sent: Thursday, February 11, 2016 3:00 PM To: Honcharik, Michelle Cc: TSTF
Subject:
[External_Sender] Industry response to NRC comments on TSTF draft letter regarding TSTF-425, "Relocate Surveillance Frequencies to Licensee Control -
RITSTF Initiative 5b"
- Michelle, We asked industry PRA experts to review the comments provided in your e-mail dated January 8.
Their only comments were on "Proposed Resolution, New Item (3rd Numbering)". The staff proposed adding:
Licensees should submit PRA quality information for their internal events PRA against RG 1.200, Revision 2, submit all peer review F&Os associated with the Internal Events PRA, and address the impact of those F&Os on the application.
The discussion stated:
Clarification Needed. Some licensees only consider an F&O to be open or closed with respect to whether they consider the F&O to be resolved in their model. The NRC currently considers an F&O to be closed if a subsequent peer review of the SR and the F&O considers it to be resolved in the model.
(Therefore, the licensee would no longer have to submit the F&O and disposition as part of the application.) All open F&Os for Internal Events should be provided. F&Os associated with those external events that are evaluated quantitatively should also be provided.
Industry comments:
- The proposed addition should state open F&Os, consistent with the discussion.
- The proposed addition should be clarified to state that only "Finding" level F&Os need be submitted. "Suggestion" level F&Os should not be submitted.
- The proposed addition should be clarified to not require submittal of self-assessment findings for plants that had Internal events peer reviews under RG 1.200 Rev 1.
Therefore, we would propose to add:
Licensees should submit PRA quality information for their internal events PRA against RG 1.200, Revision 2, submit all Finding-level peer review F&Os
associated with the Internal Events PRA that have not been closed by a subsequent peer review, and address the impact of those F&Os on the application. Internal self-assessment findings need not be submitted.
We look forward to discussing this on the 18th.
Brian Brian D. Mann Vice President of Industry Programs EXCEL Services Corporation Direct (240) 880-0490 Main (301) 984-4400 Mobile (804) 339-7034 E-mail: brian.mann@excelservices.com Web: www.excelservices.com Web: www.nukapedia.com