MONTHYEARPLA-8145, Biennial 10 CFR 50.59 and 72.48 Summary Report and Changes to Regulatory Commitments - PLA-81452024-10-21021 October 2024 Biennial 10 CFR 50.59 and 72.48 Summary Report and Changes to Regulatory Commitments - PLA-8145 PLA-8148, Registration for the Use of Spent Fuel Storage Casks 311, 308, and 3102024-10-15015 October 2024 Registration for the Use of Spent Fuel Storage Casks 311, 308, and 310 PLA-8141, Response to Request for Additional Information Regarding Relief Request 1RR06, PLA-81412024-09-18018 September 2024 Response to Request for Additional Information Regarding Relief Request 1RR06, PLA-8141 PLA-8142, Registration for the Use of Spent Fuel Storage Casks 306, 309, and 307 - PLA-81422024-09-18018 September 2024 Registration for the Use of Spent Fuel Storage Casks 306, 309, and 307 - PLA-8142 PLA-8117, 23rd Refueling Outage Owners Activity Report (PLA-8117)2024-07-23023 July 2024 23rd Refueling Outage Owners Activity Report (PLA-8117) PLA-8126, Response to Request for Confirmation of Information Regarding Relief Request 1RR062024-05-29029 May 2024 Response to Request for Confirmation of Information Regarding Relief Request 1RR06 PLA-8122, Annual Radiological Environmental Operating Report (PLA-8122)2024-05-28028 May 2024 Annual Radiological Environmental Operating Report (PLA-8122) PLA-8115, Relief Request IRR06 One Time Extension to the Fourth 10-Year Inservice Testing Program Interval (PLA-8115)2024-05-23023 May 2024 Relief Request IRR06 One Time Extension to the Fourth 10-Year Inservice Testing Program Interval (PLA-8115) PLA-8101, Re 2023 Annual Report of Radiation Exposure2024-04-22022 April 2024 Re 2023 Annual Report of Radiation Exposure PLA-8095, 2023 Annual Radiological Environmental Operating Report (PLA-8095)2024-04-22022 April 2024 2023 Annual Radiological Environmental Operating Report (PLA-8095) PLA-8094, Radioactive Effluent Release Report and Offsite Dose Calculation Manual PLA-80942024-04-22022 April 2024 Radioactive Effluent Release Report and Offsite Dose Calculation Manual PLA-8094 PLA-8113, Response to Request for Additional Information Regarding Relief Request 4RR-11 (PLA-8113)2024-04-11011 April 2024 Response to Request for Additional Information Regarding Relief Request 4RR-11 (PLA-8113) PLA-8102, Annual Environmental Operating Report (Nonradiological) PLA-81022024-04-11011 April 2024 Annual Environmental Operating Report (Nonradiological) PLA-8102 PLA-8112, Relief Request 4RR-11 Relief from End of Interval Boundary Leakage Test PLA-81122024-04-0909 April 2024 Relief Request 4RR-11 Relief from End of Interval Boundary Leakage Test PLA-8112 PLA-8110, Submittal of Unit 1 Cycle 24 Core Operating License Report (Pla 8110)2024-04-0404 April 2024 Submittal of Unit 1 Cycle 24 Core Operating License Report (Pla 8110) PLA-8100, Property Insurance Program (PLA-8100)2024-04-0101 April 2024 Property Insurance Program (PLA-8100) PLA-8109, Supplement to Request for Exemption from Certain Requirements of 10 CR 72.212 and 10 CFR 72.214 Resulting from Fuel Basket Design Control Compliance (PLA-8109)2024-03-21021 March 2024 Supplement to Request for Exemption from Certain Requirements of 10 CR 72.212 and 10 CFR 72.214 Resulting from Fuel Basket Design Control Compliance (PLA-8109) PLA-8107, Request for Exemption from Certain Requirements of 10 CFR 72.212 and 10 CFR 72.214 Resulting from Fuel Basket Design Control Compliance2024-03-19019 March 2024 Request for Exemption from Certain Requirements of 10 CFR 72.212 and 10 CFR 72.214 Resulting from Fuel Basket Design Control Compliance PLA-8099, Proof of Financial Protection and Guarantee of Payment of Deferred Premiums (PLA-8099)2024-02-13013 February 2024 Proof of Financial Protection and Guarantee of Payment of Deferred Premiums (PLA-8099) PLA-8096, Response to Request for Additional Information Regarding Proposed Relief Request for the Fifth 10-Year Inservice Test Program Interval2024-01-0404 January 2024 Response to Request for Additional Information Regarding Proposed Relief Request for the Fifth 10-Year Inservice Test Program Interval PLA-8077, Emergency Plan Revision 67 (PLA-8077)2023-12-27027 December 2023 Emergency Plan Revision 67 (PLA-8077) PLA-8088, Request for Exemption from Enhanced Weapons, Firearms Background Checks and Security Event Notifications Implementation (PLA-8088)2023-12-0505 December 2023 Request for Exemption from Enhanced Weapons, Firearms Background Checks and Security Event Notifications Implementation (PLA-8088) PLA-8089, Submittal of Revision to Inservice Testing Program Plan2023-12-0505 December 2023 Submittal of Revision to Inservice Testing Program Plan PLA-8084, Application to Revise Technical Specifications to Adopt TSTF-568, Revise Applicability of BWR TS 3.6.2.5 and TS 3.6.3.22023-11-29029 November 2023 Application to Revise Technical Specifications to Adopt TSTF-568, Revise Applicability of BWR TS 3.6.2.5 and TS 3.6.3.2 PLA-8091, Response to Request for Additional Information Regarding Proposed Relief Request for the Fifth 10-Year Inseervice Inspection Interval (PLA-8091)2023-11-0808 November 2023 Response to Request for Additional Information Regarding Proposed Relief Request for the Fifth 10-Year Inseervice Inspection Interval (PLA-8091) PLA-8082, Proposed Amendment to Licenses NPF-14 and NPF-22: Application to Revise Technical Specifications to Adopt TSTF-563, Revise Instrument Testing Definitions to Incorporate the Surveillance Frequency Control Program2023-11-0202 November 2023 Proposed Amendment to Licenses NPF-14 and NPF-22: Application to Revise Technical Specifications to Adopt TSTF-563, Revise Instrument Testing Definitions to Incorporate the Surveillance Frequency Control Program PLA-8080, Proposed Relief for Valve 251130 (PLA-8080)2023-08-14014 August 2023 Proposed Relief for Valve 251130 (PLA-8080) PLA-8074, Proposed Relief Request for the Fifth 10-Year Inservice Test Program Interval2023-08-0303 August 2023 Proposed Relief Request for the Fifth 10-Year Inservice Test Program Interval PLA-8076, Unit 2 - 21st Refueling Outage Owners Activity Report (PLA-8076)2023-07-20020 July 2023 Unit 2 - 21st Refueling Outage Owners Activity Report (PLA-8076) PLA-8078, Submittal of Unit 2 Cycle 22 Core Operating Limits Report, Revision 1, PLA-80782023-07-0505 July 2023 Submittal of Unit 2 Cycle 22 Core Operating Limits Report, Revision 1, PLA-8078 PLA-8054, Proposed Amendment to Licenses NPF-14 and NPF-22: Remove Control Rod Operability Separation Criteria and Replace Reference to Banked Position Withdrawal Sequence with the Analyzed Rod Position Sequence2023-06-0808 June 2023 Proposed Amendment to Licenses NPF-14 and NPF-22: Remove Control Rod Operability Separation Criteria and Replace Reference to Banked Position Withdrawal Sequence with the Analyzed Rod Position Sequence PLA-8073, Proposed Relief Request for the Fifth 10-Year Inservice Inspection Interval2023-06-0101 June 2023 Proposed Relief Request for the Fifth 10-Year Inservice Inspection Interval PLA-8067, Notification of Completion of Emergence from Bankruptcy (PLA-8067)2023-05-17017 May 2023 Notification of Completion of Emergence from Bankruptcy (PLA-8067) PLA-8064, Response to NRC Regulatory Issue Summary 2023-01 (PLA-8064)2023-05-17017 May 2023 Response to NRC Regulatory Issue Summary 2023-01 (PLA-8064) PLA-8066, Notification of Planned Closing Date and Information Identified in March 30, 2023 Order, PLA-80662023-05-0808 May 2023 Notification of Planned Closing Date and Information Identified in March 30, 2023 Order, PLA-8066 PLA-8053, Radiation Exposure Information and Reporting System2023-04-27027 April 2023 Radiation Exposure Information and Reporting System PLA-8058, Annual Radiological Environmental Operating Report (PLA-8058)2023-04-26026 April 2023 Annual Radiological Environmental Operating Report (PLA-8058) PLA-8041, Radioactive Effluent Release Report and Offsite Dose Calculation Manual (PLA-8041)2023-04-25025 April 2023 Radioactive Effluent Release Report and Offsite Dose Calculation Manual (PLA-8041) PLA-8047, 2022 Annual Environmental Operating Report (Nonradiological), PLA-80472023-04-19019 April 2023 2022 Annual Environmental Operating Report (Nonradiological), PLA-8047 PLA-8062, Supplement to Relief Request 4RR-10 Relief from Code Seal Weld Requirement for Valve 252F007B, PLA-80622023-04-11011 April 2023 Supplement to Relief Request 4RR-10 Relief from Code Seal Weld Requirement for Valve 252F007B, PLA-8062 PLA-8061, Relief Request 4RR-10 Relief from Code Seal Weld Requirement for Valve 25F007B, PLA-80612023-04-10010 April 2023 Relief Request 4RR-10 Relief from Code Seal Weld Requirement for Valve 25F007B, PLA-8061 PLA-8060, Submittal of Unit 2 Cycle 22 Core Operating Limits Report (PLA-8060)2023-03-30030 March 2023 Submittal of Unit 2 Cycle 22 Core Operating Limits Report (PLA-8060) PLA-8057, Application for Order Approving Indirect Transfer of Control of Licenses and Approving Conforming License Amendments- Supplemental Information, PLA-80572023-03-15015 March 2023 Application for Order Approving Indirect Transfer of Control of Licenses and Approving Conforming License Amendments- Supplemental Information, PLA-8057 PLA-8052, (Sses), Proof of Financial Protection and Guarantee of Payment of Deferred Premiums2023-02-13013 February 2023 (Sses), Proof of Financial Protection and Guarantee of Payment of Deferred Premiums PLA-8048, Response to Request for Additional Information Regarding License Amendment Requesting Temporary Addition of Analyzed Rod Position Sequence2023-01-14014 January 2023 Response to Request for Additional Information Regarding License Amendment Requesting Temporary Addition of Analyzed Rod Position Sequence PLA-8042, Proposed Emergency Amendment to License NPF-22: Temporary Addition of Analyzed Rod Position Sequence2023-01-10010 January 2023 Proposed Emergency Amendment to License NPF-22: Temporary Addition of Analyzed Rod Position Sequence PLA-8039, Application for Order Approving Indirect Transfer of Control of License Amendments - Supplemental Information2022-12-22022 December 2022 Application for Order Approving Indirect Transfer of Control of License Amendments - Supplemental Information PLA-8038, Notification of Petition for Bankruptcy (PLA-8038)2022-12-14014 December 2022 Notification of Petition for Bankruptcy (PLA-8038) PLA-8036, Registration for the Use of Spent Fuel Storage Casks 203, 202, and 204, PLA-80362022-11-30030 November 2022 Registration for the Use of Spent Fuel Storage Casks 203, 202, and 204, PLA-8036 PLA-8035, Registration for the Use of Spent Fuel Storage Casks 205, 200, and 201, PLA-80352022-11-0808 November 2022 Registration for the Use of Spent Fuel Storage Casks 205, 200, and 201, PLA-8035 2024-09-18
[Table view] |
Text
Britt T. McKInney PPL Susquehanna, LLC Sr. Vice President & Chief Nuclear Officer 769 Salem Boulevard Berwick, PA 18603 Tel. 570.542.3149 Fax 570.542.1504 PI btmcklnney@pplweb.com "iiN T JUL 2 0 2006 Mr. Stuart A. Richards, Deputy Director Division of Inspection and Regional Support Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 SUSQUEHANNA STEAM ELECTRIC STATION GROUNDWATER PROTECTION -
DATA COLLECTION QUESTIONNAIRE Docket Nos. 50-387 PLA-6086 and 50-388
Dear Mr. Richards:
The nuclear industry, in conjunction with the Nuclear Energy Institute, has developed a questionnaire to facilitate the collection of groundwater data at commercial nuclear reactor sites. The objective of the questionnaire is to compile baseline information about the current status of site programs for monitoring and protecting groundwater and to share that information with the NRC. The completed questionnaire for PPL Susquehanna, LLC is enclosed.
This submittal contains no new regulatory commitments.
Please contact Richard Doty at (610) 774-7932 if you have questions about the enclosed information.
Sincerely, B. T. McKinney
Document Control Desk PLA-6086
Attachment:
Groundwater Protection Data Collection Questionnaire cc: USNRC Document Control Desk Samuel Collins, USNRC Regional Administrator - Region I Mr. A. J. Blamey, NRC Sr. Resident Inspector Mr. R. V. Guzman, NRC Project Manager Ralph Andersen, Nuclear Energy Institute Mr. R. Janati, DEP/BRP
Attachment to PLA-6086 Groundwater Protection Data Collection Questionnaire
Attachment to PLA-6086 Page 1 of 4 Industry Groundwater Protection Initiative Voluntary Data Collection Questionnaire Plant: Susquehanna Steam Electric Station
- 1. Briefly describe the program and/or methods used for detection of leakage or spills from plant systems, structures, and components that have a potential for an inadvertent release of radioactivity from plant operations into groundwater.
ANSWER:
- Susquehanna SES has identified seven systems that are more likely to contaminate groundwater with tritium than the other plant systems: Cooling Tower (via blowdown line), Emergency Service Water, Fuel Pool, Residual Heat Removal Service Water, Ultimate Heat Sink, Condensate Transfer, and Radwaste. In the case of the Fuel Pools, a liner leakage detection system is monitored to detect leakage. There are no inspection programs to determine the condition of underground piping associated with the systems mentioned above that include underground piping. There are no inspection programs to monitor the integrity of the concrete berms around the above-surface Condensate Storage Tanks and Refueling Water Storage Tank.
The Susquehanna plant has an underdrain (French drain) system which is installed around the entire perimeter of the power block immediately above the building base slab. Groundwater, which may infiltrate into this piping system would flow to one of three foundation drain manholes. Without sump pumps, accumulation of water would occur in those manholes until the water reached the elevation of overflow pipes (to the station storm drain system). However, sump pumps are in place and actuate to direct
-the water to the overflow pipes at a level below the overflow elevation. There is no periodic radioactive-material sampling system in place at these manholes; however, a sampling program is in development as described in the answer to question 2.
- All plant systems are periodically and routinely walked down by Operations and Systems Engineering personnel independently. Additionally, Health Physics personnel perform walk-downs of radiologically controlled areas of the station.
(As noted above, there are no inspections of the underground piping). The expected response to the discovery of a system leak or spill is the notification of supervision and the generation of a Condition Report, which leads to evaluation of appropriate corrective actions. A bi-annual surveillance test is performed on the Ultimate Heat Sink for indications of gross leakage into groundwater.
- Groundwater sampling is conducted as part of the Radiological Environmental Monitoring Program (REMP). i
Attachment to PLA-6086 Page 2 of 4 Spills of potentially radioactive materials are addressed in accordance with established procedures. These procedures include notifications to appropriate plant personnel and initiation of appropriate control and clean-up actions.
- 2. Briefly describe the program and/or methods for monitoring onsite groundwater for the presence of radioactivity released from plant operations.
ANSWER:
- The REMP groundwater monitoring program consists of quarterly sampling of four wells. These wells are located within the site boundary but are outside of the Protected Area boundary (security fencing). The four wells are used for domestic water (drinking and various system support) supply to buildings within the site boundary. The water is sampled from faucets within the applicable buildings being supplied by the respective wells. The wells vary in location from 1,400 to 4,500 feet from the centerline of the Unit 1/2 reactor buildings. A well located approximately 6 miles from the site is sampled (quarterly) as a "control" location.
- The plant has a foundation drainage system for collection of groundwater along the perimeter of the reactor and turbine buildings (both units) and the radwaste building, as described in the answer to question 1. Excess water (overflow) collected from the underdrain system in the three manholes is pumped to the storm drain system. The storm water collection basin is sampled/analyzed for tritium and gamma emitting radionuclides quarterly. The three underdrain system manholes are scheduled to be added to the REMP groundwater sampling and analysis program later in 2006.
- Radiological analysis performed on groundwater samples includes tritium and gamma-emitting radionuclides. Typical groundwater sample Minimal Detectable Concentrations (MDC) are as follows:
Radionuclide MDC (pCi/L)
H-3 150 Mn-54 15 Fe-59 30 Co-58/60 15 Zn-65 30 Zr-95 30 Nb-95 15 1-131 1 Cs-134 15 Cs-137 18 Ba-140 60 La-140 15 Gross alpha 2 Gross beta 4
Attachment to PLA-6086 Page 3 of 4
- 3. If applicable, briefly summarize any occurrences of inadvertent releases of radioactive liquids that had the potential to reach groundwater and have been documented in accordance with 10 CFR 50.75(g).
ANSWER:
- Four events have been identified which are judged to have had the potential, however small, for inadvertent release to groundwater. Each event has been documented in the 10 CFR 50.75(g) files.
- The first event occurred in December 1983 (with Unit 1 in operation and Unit 2 under construction) and involved a condensate system leak into a Unit 2 Turbine Building central area sump, which was being pumped to a temporary sump outside the Unit 2 Turbine Building. The areas impacted included the central area sump inside the Unit 2 Turbine Building and the temporary sump outside the Radiologically Controlled Area. Cleanup of the affected sumps (contaminated liquid removal via pumping and sump decontamination) was promptly initiated. The potential for significant contamination of groundwater is believed to be small.
- The second event occurred in April 1988. Liquid from a spill from the Unit 2 condensate system extended beyond the Radiologically Controlled Area boundary at a Turbine Building train bay door. Cleanup of the liquid and affected soil was promptly initiated. Construction of a Tool Room has since occurred in the affected area, with that Tool Room being inside the Radiologically Controlled Area. The potential for significant contamination of groundwater is believed to be small.
- The third event occurred in July 1991. Liquid from the radwaste/condensate-transfer system was inadvertently released into a cement silo building affixed to the radwaste building. The. area impacted was the immediate vicinity of the cement silo building.
Cleanup of the area was promptly initiated. The potential for significant contamination of groundwater is believed to be small.
- The fourth event occurred in February 1995. There was a leak of condensate system water into a drain pipe in the area of the Unit 2 Condensate Storage Tank (CST) berm.
The area impacted was the Unit 2 CST berm area. Monitoring of the liquid in the berm area and the leakage path showed very low levels of radioactive material. The potential for significant contamination of groundwater is believed to be small.
Attachment to PLA-6086 Page 4 of 4
- 4. If applicable, briefly summarize the circumstances associated with any onsite or offsite groundwater monitoring result indicating a concentration in groundwater of radioactivity released from plant operations that exceeds the maximum contaminant level (MCL) established by the USEPA for drinking water.
ANSWER:
- PPL has identified no instances where a groundwater monitoring result indicated a groundwater concentration of tritium or other radionuclide released from plant operations that exceeded the MCL established by the USEPA for drinking water.
- 5. Briefly describe any remediation efforts undertaken or planned to reduce or eliminate levels of radioactivity resulting from plant operations in soil or groundwater onsite or offsite.
ANSWER:
- The potential for contamination of groundwater and/or soils is being re-evaluated as part of the on-going review of events (see question 3) involving inadvertent releases of liquid radioactive materials outside of the Radiologically Controlled Area. At this time, there is no indication that remediation efforts need to be initiated on-site or off-site, based on evaluations and sampling results obtained to date. By virtue of placement of the events in the plant decommissioning files, residual contamination, if any, resultant from the four events listed in the response to question 3, would be considered at the time of plant decommissioning.
- As noted in the response to question 3 above, the spill that occurred in April 1988 involved the removal of soils just outside a Unit 2 train bay door.