Master Report - Tables 1 and 2
ML15239B221
Person / Time
Site: Susquehanna  Talen Energy icon.png
Issue date: 11/03/2015
From:
Susquehanna
To: Quinn-Willingham L
NRC/NRO/DSEA/RHMB
Quinn-Willingham L
References
Download: ML15239B221 (3)


Text

Susquehanna, Units 1 & 2 Table 1. Current Design Basis Flood Hazards for Use in the MSA Mechanism Stillwater Waves/ Design Basis Reference Elevation Runup Hazard Elevation Local Intense Precipitation Engineered Safeguards Service 694.8 ft MSL 0.0 ft 694.8 ft MSL Letter dated September 24, 2015 to Water (ESSW) Pumphouse the NRC, "Susquehanna Steam (South side) Electric Station Flood Hazards Reevaluation Report Information to Support Audit", ADAMS Accession No. ML15267A600.

ESSW Pumphouse Valve 697.3 ft MSL 0.0 ft 697.3 ft MSL Email dated October 2, 2015 to the Chamber NRC, "Susquehanna: Follow-on Audit Question", ADAMS Accession No.

ML15288A563.

Common Diesel Generator 679.0 ft MSL 0.0 ft 679.0 ft MSL Letter dated September 24, 2015 to Building the NRC, "Susquehanna Steam Electric Station Flood Hazards Reevaluation Report Information to Support Audit", ADAMS Accession No. ML15267A600.

Unit 1 Reactor Building 672.0 ft MSL 0.0 ft 672.0 ft MSL Letter dated September 24, 2015 to the NRC, "Susquehanna Steam Electric Station Flood Hazards Reevaluation Report Information to Support Audit", ADAMS Accession No. ML15267A600.

Unit 2 Reactor Building 672.0 ft MSL 0.0 ft 672.0 ft MSL Letter dated September 24, 2015 to the NRC, "Susquehanna Steam Electric Station Flood Hazards Reevaluation Report Information to Support Audit", ADAMS Accession No. ML15267A600.

Common Diesel 'E' Building 678.0 ft MSL: 0.0 ft 678.0 ft MSL: Letter dated September 24, 2015 to the NRC, "Susquehanna Steam Electric Station Flood Hazards Reevaluation Report Information to Support Audit", ADAMS Accession No. ML15267A600.

Susquehanna, Units 1 & 2 Table 1. Current Design Basis Flood Hazards for Use in the MSA Mechanism Stillwater Waves/ Design Basis Reference Elevation Runup Hazard Elevation Spray Pond 682.4 ft MSL 2.4 ft 684.8 ft MSL FSAR Table 4-3 Streams and Rivers Susquehanna River 545.7 ft MSL 2.3 ft 548.0 ft MSL FHRR Section 2.2.2 Failure of Dams and Onsite Water Control/Storage Structures Offsite Dam Failure No Impact No Impact No Impact FHRR Section 2.2.3 and Section on the Site on the Site on the Site 2.2.3 & 2.2.7 Identified Identified Identified Cooling Tower Basin Rupture 694.8 ft MSL Not 694.8 ft MSL Letter dated September 24, 2015 to applicable the NRC, "Susquehanna Steam Electric Station Flood Hazards Reevaluation Report Information to Support Audit", ADAMS Accession No. ML15267A600.

Storm Surge No Impact No Impact No Impact FHRR Section 2.2.4 on the Site on the Site on the Site Identified Identified Identified Seiche No Impact No Impact No Impact FHRR Section 2.2.4 on the Site on the Site on the Site Identified Identified Identified Tsunami No Impact No Impact No Impact FHRR Section 2.2.4 on the Site on the Site on the Site Identified Identified Identified Ice-Induced Flooding No Impact No Impact No Impact FHRR Section 2.2.5 on the Site on the Site on the Site Identified Identified Identified

Susquehanna, Units 1 & 2 Table 1. Current Design Basis Flood Hazards for Use in the MSA Mechanism Stillwater Waves/ Design Basis Reference Elevation Runup Hazard Elevation Channel Migrations/Diversions No Impact No Impact No Impact FHRR Section 2.2.6 on the SIte on the Site on the Site Identified Identified Identified Note 1: Reported values are rounded to the nearest one-tenth of a foot.