Technical Specification 5.7.1.a requires, in part, that each
high radiation area, in which the intensity of radiation is > 100 mrem/hr but < 1000 mrem/hr, measured at 30 cm from the radiation source or from any surface the radiation penetrates, shall be barricaded and conspicuously posted as a
high radiation area. Contrary to the above, on October 14, 2008, the licensee was transferring Unit 1 condensate phase separator resin to the vendors equipment for receiving the resin; however, the licensee did not barricade nor conspicuously post the areas that contained the pipes used for transferring the resin as a
high radiation area. Licensee evaluations performed after the event showed that the intensity of radiation was >100 mrem/hr but <1000 mrem/hr measured at 30 cm from the pipe surfaces in those areas. This finding was entered in the licensees corrective action program as Condition Report 2008110421. This finding is of very low safety significance because there was no evidence of unauthorized worker entry into the area and no unexpected /unintended radiation exposures to licensee personnel