Title | Failure to Comply with Technical Specification LCOs When Reactor Vessel Level Instruments Were Declared Inoperable |
Description | The inspectors identified a finding of very low safety significance and associated NCV for a failure to comply with TS 3.0.2 by not entering TS Limiting Condition for Operation (LCO) 3.3.5.1 Condition A and TS LCO 3.3.6.1 Condition A when required. The inspectors determined that the licensee incorrectly utilized a TS Surveillance Requirement Note that allows a delay in entering the Conditions and Required Actions for the given TS LCO. As a result, the licensee failed to correctly enter the Conditions and Required Actions when reactor level instruments were declared inoperable to perform testing in support of planned maintenance. The licensee entered the issue associated with the failure to comply with TS into their corrective action program. This performance deficiency was determined to be more than minor because it impacted the Equipment Performance attribute of the Mitigating Systems Cornerstone, and adversely affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences (i.e., core damage); and if left uncorrected it could lead to a more significant safety concern. This finding is of very low safety significance because it was not a design/qualification deficiency, did not represent a loss of system safety function, did not result in a loss of function of a single train for greater than its TS-allowable outage time, did not result in a loss of function of nonsafety-related risk-significant equipment and was not risk significant due to external events. This finding has a cross-cutting aspect in the decision making component of Human Performance cross-cutting area (per IMC 0310 H.1(b)), because the licensee did not use conservative assumptions to ensure the proposed action was safe. Specifically, the licensee incorrectly used the TS Surveillance Requirement Note to satisfy maintenance requirements. |
Site: | Perry ![]() |
---|---|
Report | IR 05000440/2010004 Section 4OA2 |
Date counted | Sep 30, 2010 (2010Q3) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71152 |
Inspectors (proximate) | J Cameron L Jones M Marshfield M Phalen P Smagacz R Edwards R Leidy T Hartman V Myers W Slawinskij Cameron L Jones M Marshfield M Phalen P Smagacz R Edwards T Hartman W Slawinsk |
CCA | H.14, Conservative Bias |
INPO aspect | DM.2 |
' | |