St. Lucie, Unit 2 - NRC Generic Letter 2006-01: Steam Generator Tube Integrity and Associated Technical Specifications (TAC No. MD0105)
ML072080045
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 07/27/2007
From: Mozafari B L
NRC/NRR/ADRO/DORL/LPLII-2
To: Stall J A
Florida Power & Light Co
Mozafari B L, NRR/ADRO/DORL, 415-2020
References
GL-06-001, TAC MD0105
Download: ML072080045 (4)


Text

July 27, 2007Mr. J. A. StallSenior Vice President, Nuclear and Chief Nuclear Officer Florida Power and Light Company P.O. Box 14000 Juno Beach, FL 33408-0420

SUBJECT:

ST. LUCIE, UNIT 2 - NRC GENERIC LETTER 2006-01: STEAMGENERATOR TUBE INTEGRITY AND ASSOCIATED TECHNICAL SPECIFICATIONS (TAC NO. MD0105)

Dear Mr. Stall:

On January 20, 2006, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter(GL) 2006-01, "Steam Generator [SG] Tube Integrity and Associated Technical Specifications

[TSs]" (see Agencywide Document Access and Management System (ADAMS) Accession No. ML060200385). This GL requested that addressees either submit a description of their program for ensuring SG tube integrity for the interval between inspections or adopt alternative TS requirements for ensuring SG tube integrity. By letter dated February 17, 2006, Florida Power and Light Company, the licensee for St. Lucie,Unit 2, submitted a response to GL 2006-01 (ADAMS Accession No. ML060530640). This response provided a regulatory commitment to submit a request to modify the SG portion of the TSs. By application to the NRC dated May 25, 2006, the licensee requested changes to the TSs for St. Lucie, Unit 2, to adopt the alternative TS requirements for ensuring SG tube integrity (ML061510346). The new TSs were modeled after Technical Specification Task Force (TSTF)

Traveler, TSTF-449, "Steam Generator Tube Integrity" (ML051090200). By letters dated January 22, 2007 (ML070250070) and April 16, 2007 (ML071210531), the licensee provided the NRC supplements to the original application. On May 29, 2007, the NRC staff issued Amendment No. 147 to the St. Lucie, Unit 2, Facility Operating License that approved the new SG TSs (ML071490483).The NRC staff finds the licensee's adoption of new SG TSs modeled after TSTF-449 to be anacceptable and complete response to GL 2006-01. This completes the NRC staff's efforts on TAC No. MD0105. If you have any questions regarding this letter, please contact me at 301-415-2020.Sincerely, /RA/Brenda L. Mozafari, Senior Project Manager Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor RegulationDocket No. 50-389 cc: See next page

ML060530640). This response provided a regulatory commitment to submit a request to modify the SG portion of the TSs. By application to the NRC dated May 25, 2006, the licensee requested changes to the TSs for St. Lucie, Unit 2, to adopt the alternative TS requirements for ensuring SG tube integrity (ML061510346). The new TSs were modeled after Technical Specification Task Force (TSTF)

Traveler, TSTF-449, "Steam Generator Tube Integrity" (ML051090200). By letters dated January 22, 2007 (ML070250070) and April 16, 2007 (ML071210531), the licensee provided the NRC supplements to the original application. On May 29, 2007, the NRC staff issued Amendment No. 147 to the St. Lucie, Unit 2, Facility Operating License that approved the new SG TSs (ML071490483).The NRC staff finds the licensee's adoption of new SG TSs modeled after TSTF-449 to be anacceptable and complete response to GL 2006-01. This completes the NRC staff's efforts on TAC No. MD0105. If you have any questions regarding this letter, please contact me at 301-415-2020.Sincerely, /RA/Brenda L. Mozafari, Senior Project Manager Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor RegulationDocket No. 50-389cc: See next page DISTRIBUTION

PUBLICLPL2-2 R/FRidsNrrDorlLpl2-2RidsNrrPMBMozafariRidsNrrLABClayton (Hard Copy)RidsOgcRpRidsAcrsAcnwMailCenterRidsNrrDciCsgbRidsRgn2MailCenterRidsNrrDorlDprADAMS ACCESSION NO: ML072080045OFFICELPL2-2/PMLPL2-2/LANRR/CSGB/BCLPL2-2/BCNAMEBMozafariBClaytonAHiserTBoyce/LRaghavan forDATE 07/27/200707/27/200707/27/200707/27/2007 Florida Power and Light CompanyST. LUCIE PLANT cc:Mr. William E. Webster Vice President, Nuclear Operations, South Region Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420 Senior Resident Inspector St. Lucie Plant U.S. Nuclear Regulatory Commission P.O. Box 6090 Jensen Beach, Florida 34957 Craig Fugate, Director Division of Emergency Preparedness Department of Community Affairs 2740 Centerview Drive Tallahassee, Florida 32399-2100 M. S. Ross, Managing Attorney Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420

Marjan Mashhadi, Senior Attorney Florida Power & Light Company 801 Pennsylvania Avenue, NW.

Suite 220 Washington, DC 20004Mr. Douglas Anderson County Administrator St. Lucie County 2300 Virginia Avenue Fort Pierce, Florida 34982

Mr. William A. Passetti, Chief Department of Health Bureau of Radiation Control 2020 Capital Circle, SE, Bin #C21 Tallahassee, Florida 32399-1741Mr. Gordon L. Johnston Site Vice President St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957-2000Mr. Christopher R. CostanzoPlant General Manager St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957Mr. Terry PattersonLicensing Manager St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957Don E. GrissetteVice President, Nuclear Training and Performance Improvement Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420Mr. Rajiv S. KundalkarVice President - Nuclear Technical Services Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408-0420Mr. J. KammelRadiological Emergency Planning Administrator Department of Public Safety 6000 Southeast Tower Drive Stuart, Florida 34997Mr. Bill ParksOperations Manager St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957-2000Mr. Seth B. DustonTraining Manager St. Lucie Nuclear Plant 6351 South Ocean Drive Jensen Beach, Florida 34957-2000