Semantic search

Jump to navigation Jump to search
Condition
Printout selection
Options
Parameters [
limit:

The maximum number of results to return
offset:

The offset of the first result
link:

Show values as links
headers:

Display the headers/property names
mainlabel:

The label to give to the main page name
intro:

The text to display before the query results, if there are any
outro:

The text to display after the query results, if there are any
searchlabel:

Text for continuing the search
default:

The text to display if there are no query results
class:

An additional CSS class to set for the table
transpose:

Display table headers vertically and results horizontally
sep:

The separator between results
prefix:

Control display of namespace in printouts
Sort options
Delete
Add sorting condition
 Issue dateTitleTopic
ML20072A84723 January 1990Rev 2 to Calculation 071, Review Statement for Safety Related Calculations
ML20082U5858 May 1991Liner Attachment Welds ServiceabilityNon-Destructive Examination
Safe Shutdown Earthquake
Hydrostatic
Operating Basis Earthquake
Finite Element Analysis
Liquid penetrant
ML20101G04717 June 1992Rev 3 to Calculation 2-FP-0085 Raceway & Firezone R Cable Supports AnalysisSafe Shutdown
Fire Barrier
ML20104B40013 February 1992Rev 1 to Calculation RXE-TA-CP1/0-027, Undervoltage/ Underfrequency Reactor Trip Setpoints
ML20105A79814 August 1992Rev 0 to Calculation of Thermal Response for Sprinkler & Raceway SupportsSafe Shutdown
ML20115B6852 March 1992Rev 0 to 2-NP-GENX-544, Reconciliation of Local Stress Evaluation Using ME215 AnalysisFinite Element Analysis
ML20116A03417 July 1996Rev 0 to Temp Vs Distance Profile for 10 RHR Line Containing Stagnant WaterCoatings
Anchor Darling
ML20127H20912 November 1991Calculation 2-NP-GENX-551, Evaluation of NUREG-0797 Suppl 1A (Sser 14) App a Sections 12.1 & 12.2
ML20128G94922 January 1993Calculation of Weights Due to Fire Protection MatlSafe Shutdown
Fire Barrier
ML20128G95529 December 1992Design Validation of Conduits W/ThermolagSafe Shutdown
ML20128G96824 February 1987Cable Ampacity Derating Factors for Conduits Boxed in W/ Thermolag (TSI Product)
ML20128G9862 October 1992Ampacity of Power Cable Wrapped W/330-660 Installed as Free Air Drop
ML20148F1134 April 1986Rev 0 to Justification of Design Load for Struts/Snubbers & Lugs Used in Conjunction W/Riser Clamp
ML20148F21519 November 1987Rev 0 to Potential Binding of Lugs in Axial Supports
ML20148F25222 May 1987Rev 0 to Evaluation of Fluid Transient Cutoff Forces & Development of Screening Criteria for Piping Sys
ML20148F33528 August 1986Rev 2 to Development of Method for Evaluating Local Stress in Pipe Support Members
ML20148F45916 September 1986Rev 0 to Fatigue Cycle Determination for Pipe Supports
ML20148F49210 September 1986Rev 2 to Documentation of Use of Low Strength A563 Grade a Double Nuts on High Strength SA 193 Grade B-7th D Rod for Richmond Insert Bolt Connection
ML20148F71821 April 1982Rev 1 to Stress Intensification Factors for Lateral Branches Fabricated from `Welded-In' Piping to Be Used in ASME Class 3 & ANSI B31.1 Pipe Stress AnalysisFinite Element Analysis
ML20148F82021 January 1988Rev 0 to Investigation of SIF for Weld Shrinkage
ML20148F86321 January 1988Rev 1 to Parallel SnubbersHydrostatic
Finite Element Analysis
Backfit
ML20207D72323 December 1986Pipe Support Calculation:General Calculation for Richmond Insert/Tube Steel Connections Design Mods
ML20207D74823 December 1986Generic Calculation:Evaluation of Npsi Rear Brackets, Dimension for Design Calculation
ML20210E46125 August 1986Rev 3 to Calculation M-25, Base Plate Prying Action FactorsSafe Shutdown Earthquake
Finite Element Analysis
FLEX
Earthquake
ML20210E49121 March 1986Rev 1 to Calculation M-04, Base Angle Stiffness
ML20210E52215 October 1986Rev 2 to Calculation M-10, Cable Tray - Clip Angle Stiffness
ML20210E57510 October 1986Rev 2 to Calculation M-12, Qualification Procedures for Cable Tray Support Evaluation
ML20210E5997 November 1986Rev 2 to Calculation 020-040-M19, Clip Stiffness Production Value
ML20210E61729 May 1986Rev 0 to Calculation M-27, Thermal Load Position Paper
ML20210E62631 August 1986Rev 0 to Calculation M-28, Justification of Clip Modeling Procedure
ML20210E68131 October 1986Rev 4 to Calculation M-03, Cable Tray Properties
ML20210E70327 May 1986Rev 0 to Calculation M-39, Siderail Extension Study
ML20236L88931 October 1986Rev 1 to CT-1-137-702-S25R, Pipe Support Calculation. Supporting Documentation Encl
ML20236L90919 February 1987Rev 1 to CT-1-137-701-S25R, Pipe Support Calculation
ML20236L93731 July 1986Rev 1 to Calculation CT-1-032, Texas Util Generating Co Comanche Peak Steam Electric Station Containment Spray Sys 15454-NP(H)
ML20247G41131 March 1989Transit Time Flow Meter Calculations