ML17266A02214 December 1978Reportable Occurrence 335-B-78-08 on 781117:condenser Temp Rise Exceeded 24 F,Caused by Circulating Water Sys Fouling, But Discharge Canal Temp Did Not Exceed 111 F Degrees
ML17266A10424 September 1979RO-335-79-30:on 790921,low Level Trip Setpoint of Reactor Protection Sys Steam Generator in Error by Approx 2%.Caused by Vendor Using Design Specs Rather than as-built Dimensions to Establish Instrument Span.Setpoint Raised
ML17266A10528 September 1979RO 335-79-31:on 790927,during Outage,Qa/Qc Verification of Installation of New Safety Injection Tank Sample Lines Revealed Four Raceway Clips Welded to Containment Vessel Wall.Clips Removed & Reinstalled in Proper Location
ML17266A1568 January 1980RO 335-B-79-05/B:on 791210,during Routine Checks of Recording Thermographs,Ocean Discharge Area Recording Thermograph Flotation Buoy Assembly Found Missing.Caused by Cable Failure from Rough Weather or Vandalism
ML17266A16017 March 1980RO 335-80-13:on 800314,while Plant Was in Cold Shutdown, Field Leads to Excitors on Both Diesel Generator Units Were Found Undersized.Caused by Design Error.Field Leads Will Be Replaced & Permanent Repair Studied
ML17266A19814 April 1980Ro:On 800411,determination Made That Rosemount Model 1152 Pressure Transmitters,Which Actuate Containment Vacuum Relief Valves FCV-25-7 & FCV-25-8,may Be Defective.Cause Not Stated.Transmitters Will Be Replaced
ML17266A20412 May 1980RO 335-80-25:on 800512,during Planned Secondary Plant Cooldown/Depressurization for Turbine Steam Seal Repair, Main Steam Header Would Not Depressurize Following MSIV Closure.Apparently Caused by Mispositioned Valve
ML17266A21115 May 1980RO 335-80-27:on 800514,C-E Informed Util That Partial Draining of RCS While in Mode 5 Is Condition Not Analyzed for Boron Dilution Event.Plant Operating Procedures Revised to Increase Shutdown MarginShutdown Margin
ML17266A21611 June 1980RO 335-80-29:on 800611,ground Occurred on Bus 1B Dc Causing Containment Isolation Valve HCV-14-6 to Fail Closed. Apparently Caused by Water in Solenoid from Steam Leak. Cooldown Continuing.Damaged Valve Seals Will Be Replaced
ML17266A45224 April 1981RO 335-81-19:on 810410,notification Made to NRC of Analyses Utilizing FSAR Assumptions for Certain Postulated Accidents Using Assumption That Reactor Coolant Pressure Tripped Upon Receipt of Sias.Item Determined Not Reportable
ML17301A15021 January 1985Special Rept:On 841220,during Surveillance Run of Diesel Generator 2B While Unit Shut Down,Radiator Cooling Fan Hub Found Loosened & Cracked Circumferentially.Mod Issued to Eliminate Possibility of Set Screw Loosening
ML19253B39619 September 1979RO-335-79-30:on 790918,during Insp & Evaluation of Pipe Restraints & Supports,Two Restraints on ECCS Piping Sys Were Found to Be in Nonconformance.Both Restraint Errors Corrected
ML20003B66419 December 1980Nonroutine Environ Operating Rept 335-B-80-03:on 801202, Ocean Intake Area Recording Thermograph Sys Was Reported Missing.Probably Caused by Storm Surge Wave Action or Commercial Fishing.Sys Was Replaced on 801210
ML20011A79926 October 1981RO 335-81-46:steam Generator Tube Eddy Current Test Performed in Ctr Area of B Steam Generator to Confirm Leak Located by Helium Test.Cause Not Stated.Testing of Rows 1-18 Will Be Completed within 2 to 3 Days
ML20023C4099 May 1983RO 389-83-005:on 830507,safety Injection Tank Isolation Valves Closed W/Plant in Mode 4 Above 276 Psia.Caused by Personnel Error.Procedural Step Overlooked During Plant Heatup.Valves Immediately Opened