ENS 41444: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
 
Line 17: Line 17:
| event date = 02/15/2005 20:55 EST
| event date = 02/15/2005 20:55 EST
| last update date = 03/30/2005
| last update date = 03/30/2005
| title = Possible Failure To Meet Design Basis Requirements Of Positive Pressure In The Control Tower Envelope Following A Design Basis Accident.
| title = Possible Failure to Meet Design Basis Requirements of Positive Pressure in the Control Tower Envelope Following a Design Basis Accident.
| event text = The licensee provided the following information:
| event text = The licensee provided the following information:
During operator rounds it was discovered that a double door for the control tower habitability envelope was propped open [from painting earlier in the day].  This condition would have resulted in not meeting the design basis requirements of maintaining a positive pressure inside the control tower envelope following a design basis accident.  The doors were immediately closed.
During operator rounds it was discovered that a double door for the control tower habitability envelope was propped open [from painting earlier in the day].  This condition would have resulted in not meeting the design basis requirements of maintaining a positive pressure inside the control tower envelope following a design basis accident.  The doors were immediately closed.

Latest revision as of 21:21, 1 March 2018

ENS 41444 +/- *RETRACTED*
Where
Three Mile Island Constellation icon.png
Pennsylvania (NRC Region 1)
Reporting
10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition

10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident
Time - Person (Reporting Time:+239.07 h9.961 days <br />1.423 weeks <br />0.327 months <br />)
Opened: Randy Campbell
00:59 Feb 26, 2005
NRC Officer: Chauncey Gould
Last Updated: Mar 30, 2005
41444 - NRC Website
Loading map...