ENS 42684: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
 
Line 16: Line 16:
| event date = 06/30/2006 19:49 EDT
| event date = 06/30/2006 19:49 EDT
| last update date = 07/03/2006
| last update date = 07/03/2006
| title = 24 Hour License Condition Report - Main Steam Isolation Valve Inoperable Greater Than 4 Hours
| title = 24 Hour License Condition Report - Main Steam Isolation Valve Inoperable Greater than 4 Hours
| event text = FPL Energy Seabrook has discovered a condition that was prohibited by the Technical Specifications. This report is being made pursuant to License Condition 2.G of the Seabrook Station Operating License.
| event text = FPL Energy Seabrook has discovered a condition that was prohibited by the Technical Specifications. This report is being made pursuant to License Condition 2.G of the Seabrook Station Operating License.
On July 3 at 0615, it was determined that a MSIV had been inoperable for a period of time longer than allowed by the Technical Specifications.  On June 30 at 1949, an alarm was received indicating a problem with the MSIV.  A troubleshooting and repair plan was developed and the MSIV repaired on July 1 at 1559.
On July 3 at 0615, it was determined that a MSIV had been inoperable for a period of time longer than allowed by the Technical Specifications.  On June 30 at 1949, an alarm was received indicating a problem with the MSIV.  A troubleshooting and repair plan was developed and the MSIV repaired on July 1 at 1559.

Latest revision as of 21:18, 1 March 2018

ENS 42684 +/-
Where
Seabrook NextEra Energy icon.png
New Hampshire (NRC Region 1)
Reporting
Other Unspec Reqmnt
Time - Person (Reporting Time:+64.57 h2.69 days <br />0.384 weeks <br />0.0884 months <br />)
Opened: M. Arsenault
16:23 Jul 3, 2006
NRC Officer: John Mackinnon
Last Updated: Jul 3, 2006
42684 - NRC Website