TABLE 3.6-1 (continued)
TABLE 3.6-1 (continued)
CONTAINMENT ISOLATION VALVES VALVE NUMBER                   FUNCTION                 ISOLATION TIME (seconds)
CONTAINMENT ISOLATION VALVES VALVE NUMBER FUNCTION ISOLATION TIME (seconds)
LRV-45             iso. LR test panel from RB             NA LRV-44                           "
LRV-45 iso. LR test panel from RB NA LRV-44 NA LRV-46 NA LRV-87 & 88*
NA LRV-46                           "
iso. H recombiner ports from RB NA 2
NA LRV-87 & 88*       iso. H2recombiner ports from RB       NA LRV-89 & 90*                     "
LRV-89 & 90*
NA LRV-91 & 92*                     "
NA LRV-91 & 92*
NA LRV-93 & 94*                     "
NA LRV-93 & 94*
NA
NA 3.
: 3. MSV-146 #           iso. misc. waste storage             NA tank from RCSG-1B                     NA
MSV-146 #
                  - MSV-128 #                       "
iso. misc. waste storage NA tank from RCSG-1B NA
NA
- MSV-128 #
: 4. _ NGV-62             iso. NG system from steam             NA generators NGV-81 #                         "
NA 4.
NA NGV-82             iso. NG system from pzr.               NA
_ NGV-62 iso. NG system from steam NA generators NGV-81 #
: 3. SAV-24             iso. SA from RB                       NA SAV-23 & 122                     "
NA NGV-82 iso. NG system from pzr.
NA
NA 3.
: 6. SFV-18             iso SF system                           NA SFV-19                           "
SAV-24 iso. SA from RB NA SAV-23 & 122 NA 6.
NA SFV-Il9 #         iso. Fuel Transfer tubes from           NA F.T. Canal SFV-120 #                       "
SFV-18 iso SF system NA SFV-19 NA SFV-Il9 #
NA 7     WSV-1             Iso. containment monitoring             NA system from RB WSV-2                           "
iso. Fuel Transfer tubes from NA F.T. Canal SFV-120 #
NA D. PENETRATIONS REQUIRING TYPE B TESTS Blind Flange 119               iso. RB                   NA Blind Flange 120                     "
NA 7
NA Blind Flange 202                     "
WSV-1 Iso. containment monitoring NA system from RB WSV-2 NA D. PENETRATIONS REQUIRING TYPE B TESTS Blind Flange 119 iso. RB NA Blind Flange 120 NA Blind Flange 202 NA B507010303 850625 PDR ADOCK 05000302 P
NA B507010303 850625 PDR   ADOCK 05000302 P                   PDR CRYSTAL RIVER - UNIT 3                 3/4 6-21 L}}
PDR CRYSTAL RIVER - UNIT 3 3/4 6-21 L}}

Latest revision as of 15:41, 12 December 2024

Proposed Tech Spec Page 3/4 6-21 Re Containment Isolation Valves
ML20127M628
Person / Time
Site: Crystal River 
Issue date: 06/25/1985
From:
FLORIDA POWER CORP.
To:
Shared Package
ML20127M614 List:
References
NUDOCS 8507010303
Download: ML20127M628 (1)


Text

_

TABLE 3.6-1 (continued)

CONTAINMENT ISOLATION VALVES VALVE NUMBER FUNCTION ISOLATION TIME (seconds)

LRV-45 iso. LR test panel from RB NA LRV-44 NA LRV-46 NA LRV-87 & 88*

iso. H recombiner ports from RB NA 2

LRV-89 & 90*

NA LRV-91 & 92*

NA LRV-93 & 94*

NA 3.

MSV-146 #

iso. misc. waste storage NA tank from RCSG-1B NA

- MSV-128 #

NA 4.

_ NGV-62 iso. NG system from steam NA generators NGV-81 #

NA NGV-82 iso. NG system from pzr.

NA 3.

SAV-24 iso. SA from RB NA SAV-23 & 122 NA 6.

SFV-18 iso SF system NA SFV-19 NA SFV-Il9 #

iso. Fuel Transfer tubes from NA F.T. Canal SFV-120 #

NA 7

WSV-1 Iso. containment monitoring NA system from RB WSV-2 NA D. PENETRATIONS REQUIRING TYPE B TESTS Blind Flange 119 iso. RB NA Blind Flange 120 NA Blind Flange 202 NA B507010303 850625 PDR ADOCK 05000302 P