| event text = At 0159 EDT on 09/08/2021, the HPCI pump discharge valve failed to reopen during a valve surveillance, resulting in the HPCI system being declared INOPERABLE.  HPCI does not have a redundant system; therefore, this condition is being reported as an eight-hour, non-emergency notification per 10 CFR 50.72(b)(3)(v).  Reactor Core Isolation Cooling system and low pressure Emergency Core Cooling Systems were OPERABLE during this time.   
| event text = At 0159 EDT on 09/08/2021, the HPCI pump discharge valve failed to reopen during a valve surveillance, resulting in the HPCI system being declared INOPERABLE.  HPCI does not have a redundant system; therefore, this condition is being reported as an eight-hour, non-emergency notification per 10 CFR 50.72(b)(3)(v).  Reactor Core Isolation Cooling system and low pressure Emergency Core Cooling Systems were OPERABLE during this time.   
There was no impact on the health and safety of the public or plant personnel.  The NRC Resident Inspector has been notified.
There was no impact on the health and safety of the public or plant personnel.  The NRC Resident Inspector has been notified.
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2021/20210909en.html#en55448
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2021/20210910en.html#en55448
}}{{unit info
}}{{unit info
| Unit = 1
| Unit = 1

Latest revision as of 06:30, 10 September 2021

ENS 55448 +/-
Where
Hatch Southern Nuclear icon.png
Georgia (NRC Region 2)
Reporting
10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident
Time - Person (Reporting Time:+2.68 h0.112 days <br />0.016 weeks <br />0.00367 months <br />)
Opened: Ryan Fannin
08:40 Sep 8, 2021
NRC Officer: Brian Lin
Last Updated: Sep 8, 2021
55448 - NRC Website