LIC-09-0074, Transmittal of Fort Calhoun Station (Fcs), Unit 1, Core Operating Limit Report (Colr), Revision 38: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
Line 16: Line 16:


=Text=
=Text=
{{#Wiki_filter:Omaha Public Power District Fort Calhoun Station P.O. Box 550, Fort Calhoun, NE 68023 September 14, 2009 LIC-09-0074 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555  
{{#Wiki_filter:OmahaPublic Power District Fort Calhoun Station P.O. Box 550, Fort Calhoun, NE 68023 September 14, 2009 LIC-09-0074 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555


==Reference:==
==Reference:==
 
Docket No. 50-285
Docket No. 50-285  


==SUBJECT:==
==SUBJECT:==
Transmittal of Fort Calhoun Station (FCS), Unit No. 1, Core Operating Limit Report (COLR), Revision 38 Pursuant to FCS Technical Specification 5.9.5d, Revision 38 of the FCS COLR is attached.
Transmittal of Fort Calhoun Station (FCS), Unit No. 1, Core Operating Limit Report (COLR), Revision 38 Pursuant to FCS Technical Specification 5.9.5d, Revision 38 of the FCS COLR is attached. Revision 38, issued on September 1, 2009, revised the Cycle 25 fuel centerline melt limit from 23.416 kw/ft to 22.705 kw/ft.
Revision 38, issued on September 1, 2009, revised the Cycle 25 fuel centerline melt limit from 23.416 kw/ft to 22.705 kw/ft.No regulatory commitments are contained in this submittal.
No regulatory commitments are contained in this submittal.
If you have any questions, please contact Ms. Susan Baughn at (402) 533-7215.Sincerely, T. C. Matthews Manager -Nuclear Licensing TCM/mle  
If you have any questions, please contact Ms. Susan Baughn at (402) 533-7215.
Sincerely, T. C. Matthews Manager - Nuclear Licensing TCM/mle


==Attachment:==
==Attachment:==
 
TDB-VI - Technical Data Book - Core Operating Limit Report - Revision 38 c:         E. E. Collins, NRC Regional Administrator, Region IV (w/o Attachment)
TDB-VI -Technical Data Book -Core Operating Limit Report -Revision 38 c: E. E. Collins, NRC Regional Administrator, Region IV (w/o Attachment)
A. B. Wang, NRC Project Manager (w/o Attachment)
A. B. Wang, NRC Project Manager (w/o Attachment)
J. C. Kirkland, NRC Senior Resident Inspector (w/o Attachment)
J. C. Kirkland, NRC Senior Resident Inspector (w/o Attachment)
Employment with Equal Opportunity PAGE 1 OF 19 Fort Calhoun Station Unit 1 TDB-VI TECHNICAL DATA BOOK CORE OPERATING LIMIT REPORT Change No. EC 46602 Reason for Change Revised Cycle 25 Fuel Centerline Melt Limit from 23.416 kw/ft to 22.705 kw/ft.Requestor C. Waszak Preparer L. Hautzinger Issue Date 09-01-09 3:00 pm R38 FORT CALHOUN STATION TECHNICAL DATA BOOK TDB-VI PAGE 2 OF 19 Fort Calhoun Station, Unit 1 Core Operating Limit Report Due to the critical aspects of the safety analysis inputs contained in this report, changes may not be made to this report without concurrence of the Nuclear Engineering Department.
Employment with Equal Opportunity
R38 FORT CALHOUN STATION TDB-VI TECHNICAL DATA BOOK PAGE 3 OF 19 TABLE OF CONTENTS Item Description Pagqe 1. IN T R O D U C T IO N ............................................................................................
 
6 2. CO RE O PERATING LIM ITS ...........................................................................
PAGE 1 OF 19 Fort Calhoun Station Unit 1 TDB-VI TECHNICAL DATA BOOK CORE OPERATING LIMIT REPORT Change No.       EC 46602 Reason for Change Revised Cycle 25 Fuel Centerline Melt Limit from 23.416 kw/ft to 22.705 kw/ft.
6 3 .T M /LP LIM IT ......................
Requestor         C. Waszak Preparer         L. Hautzinger Issue Date       09-01-09 3:00 pm R38
I .........................................................................  
 
..8 4. MAXIMUM CORE INLET TEMPERATURE  
FORT CALHOUN STATION                                                                         TDB-VI TECHNICAL DATA BOOK                                                                   PAGE 2 OF 19 Fort Calhoun Station, Unit 1 Core Operating Limit Report Due to the critical aspects of the safety analysis inputs contained in this report, changes may not be made to this report without concurrence of the Nuclear Engineering Department.
....................................................
R38
8 5. POWER DEPENDENT INSERTION LIMIT ....................................................
 
8 6. LIN EA R H EA T RA TE ......................................................................................
FORT CALHOUN STATION                                                                                                           TDB-VI TECHNICAL DATA BOOK                                                                                                       PAGE 3 OF 19 TABLE OF CONTENTS Item   Description                                                                                                             Pagqe
9 7. EXCORE MONITORING OF LHR ...................................................................
: 1.       IN T R O D UC T IO N ............................................................................................ 6
9 8. PEA KING FACTO R LIM ITS ...........................................................................
: 2.       CO RE O PERATING LIM ITS ...........................................................................                 6
9 9. D N B M O N IT O R IN G ........................................................................................
: 3.       T M/LP LIM IT ...................... I.........................................................................     .. 8
9 10. FRT AND CORE POWER LIMITATIONS  
: 4.       MAXIMUM CORE INLET TEMPERATURE ....................................................                                   8
........................................................
: 5.       POWER DEPENDENT INSERTION LIMIT ....................................................                                 8
9 11. REFUELING BORON CONCENTRATION  
: 6.       LIN EA R HEA T RA TE ......................................................................................           9
......................................................
: 7.       EXCORE MONITORING OF LHR ...................................................................                         9
9 12. AXIAL POWER DISTRIBUTION  
: 8.       PEA KING FACTO R LIM ITS ...........................................................................                 9
..................................................................
: 9.       D N B MO NIT O R IN G ........................................................................................       9
10 13. SHUTDOWN MARGIN WITH Tcold > 210-F .................................................
: 10.     FRT AND CORE POWER LIMITATIONS ........................................................                             9
10 14. MOST NEGATIVE MODERATOR TEMPERATURE COEFFICIENT  
: 11.     REFUELING BORON CONCENTRATION ...................................................... 9
............
: 12. AXIAL POWER DISTRIBUTION ..................................................................                           10
10 15. STEAM GENERATOR DIFFERENTIAL PRESSURE ...................................
: 13.     SHUTDOWN MARGIN WITH Tcold > 210-F .................................................                                 10
10 R38 FORT CALHOUN STATION TDB-VI TECHNICAL DATA BOOK PAGE 4 OF 19 LIST OF TABLES Table No. Title Page 1 T M /LP C oeffi cients ..........................................................................................
: 14.     MOST NEGATIVE MODERATOR TEMPERATURE COEFFICIENT ............ 10
8 2 Refueling Boron Concentrations  
: 15. STEAM GENERATOR DIFFERENTIAL PRESSURE ...................................                                             10 R38
.....................................................................
 
9 R38 FORT CALHOUN STATION TECHNICAL DATA BOOK TDB-VI PAGE 5 OF 19 LIST OF FIGURES Figure No.1 2 3 4 5 6 7 8 9 Title Page Thermal Margin/Low Pressure for 4 Pump Operation  
FORT CALHOUN STATION                                                                                                       TDB-VI TECHNICAL DATA BOOK                                                                                                 PAGE 4 OF 19 LIST OF TABLES Table No. Title                                                                                                             Page 1     T M/LP C oeffi cients .......................................................................................... 8 2     Refueling Boron Concentrations .....................................................................               9 R38
.....................................
 
11 Power Dependent Insertion Limit ...................................................................
FORT CALHOUN STATION                                                                                                             TDB-VI TECHNICAL DATA BOOK                                                                                                       PAGE 5 OF 19 LIST OF FIGURES Figure No. Title                                                                                                                  Page 1     Thermal Margin/Low Pressure for 4 Pump Operation .....................................                                   11 2      Power Dependent Insertion Limit ...................................................................                       12 3      Allowable Peak Linear Heat Rate vs. Burnup ................................................                               13 4      Excore Monitoring of LH R ................................................................................               14 5      D N B Mo nito ring ............................................................................................       . . 15 6      FRT   and Core Power Limitations ....................................................................                     16 7      Axial Power Distribution LSSS for 4 Pump Operation ..................................... 17 8      Axial Power Distribution Limits for 4 Pump Operation with Incores Inoperable.. 18 9      Minimum Boric Acid Storage Tank Level vs. Stored Boric Acid Storage Tank C o nce ntratio n ................................................................................................     .. 19 R38
12 Allowable Peak Linear Heat Rate vs. Burnup ................................................
 
13 Excore M onitoring of LH R ................................................................................
FORT CALHOUN STATION                                                                       TDB-VI TECHNICAL DATA BOOK                                                                 PAGE 6 OF 19 CORE OPERATING LIMIT REPORT
14 D N B M o nito ring ............................................................................................  
: 1. INTRODUCTION This report provides the cycle-specific limits for operation of the Fort Calhoun Station Unit 1 for Cycle 25 operation. It includes limits for:
..15 FRT and Core Power Limitations  
* TM/LP LSSS for 4 Pump Operation     (PVAR)
....................................................................
    " Core Inlet Temperature     (TIN)
16 Axial Power Distribution LSSS for 4 Pump Operation  
* Power Dependent Insertion Limit (PDIL)
.....................................
* Allowable Peak Linear Heat Rate
17 Axial Power Distribution Limits for 4 Pump Operation with Incores Inoperable..
* Excore Monitoring of LHR
18 Minimum Boric Acid Storage Tank Level vs. Stored Boric Acid Storage Tank C o nce ntratio n ................................................................................................  
* Integrated Radial Peaking Factor (FRT)
.. 19 R38 FORT CALHOUN STATION TDB-VI TECHNICAL DATA BOOK PAGE 6 OF 19 CORE OPERATING LIMIT REPORT 1. INTRODUCTION This report provides the cycle-specific limits for operation of the Fort Calhoun Station Unit 1 for Cycle 25 operation.
* DNB Monitoring
It includes limits for:* TM/LP LSSS for 4 Pump Operation (PVAR)" Core Inlet Temperature (TIN)* Power Dependent Insertion Limit (PDIL)* Allowable Peak Linear Heat Rate* Excore Monitoring of LHR* Integrated Radial Peaking Factor (FRT)* DNB Monitoring
* FRT versus Power Trade-off Curve
* FRT versus Power Trade-off Curve" Refueling Boron Concentration" Axial Power Distribution (APD)* Shutdown Margin with TCOLD > 210°F* Most Negative Moderator Temperature Coefficient These limits are applicable for the duration of the cycle. For subsequent cycles the limits will be reviewed and revised as necessary.
    " Refueling Boron Concentration
In addition, this report includes a number of cycle-specific coefficients used in the generation of certain reactor protective system trip setpoints or allowable increases in radial peaking factors.2. CORE OPERATING LIMITS All values and limits in this TDB section apply to Cycle 25 operation.
    " Axial Power Distribution (APD)
This cycle must be operated within the bounds of these limits and all others specified in the Technical Specifications.
* Shutdown Margin with   TCOLD > 210°F
This report has been prepared in accordance with the requirements of Technical Specification 5.9.5. The list of references below are complete citations of topical reports and include the report number, title, revision, date, and any supplements in accordance with the basis for NRC approval of License Amendment No. 196 which eliminated these specific entries from Technical Specification 5.9.5. NRC approval of Amendment No. 196 is consistent with the requirements of the Technical Specification Task Force, Improved Standard Technical Specification Change Traveler, "Revise Topical Report References in ITS 5.6.5 COLR" (TSTF-363-A, Rev. 0). In accordance with this Traveler and Amendment No. 196, this information must be maintained within this TDB section.R38 FORT CALHOUN STATION TDB-VI TECHNICAL DATA BOOK PAGE 7 OF 19 The values and limits presented within this TDB section have been derived using the NRC approved methodologies listed below:* OPPD-NA-8301, "Reload Core Analysis Methodology Overview," Revision 8, dated August 2004. (TAC No. MC4304)* OPPD-NA-8302, "Reload Core Analysis Methodology, Neutronics Design Methods and Verification," Revision 6, dated August 2004. (TAC No. MC4304)" OPPD-NA-8303, "Reload Core Analysis Methodology, Transient and Accident Methods and Verification," Revision 7, dated August 2005. (TAC No. MC4304)" XN-75-32(P)(A)
* Most Negative Moderator Temperature Coefficient These limits are applicable for the duration of the cycle. For subsequent cycles the limits will be reviewed and revised as necessary. In addition, this report includes a number of cycle-specific coefficients used in the generation of certain reactor protective system trip setpoints or allowable increases in radial peaking factors.
Supplements 1, 2, 3, & 4, "Computational Procedure for Evaluating Fuel Rod Bowing," October 1983." XN-NF-79-56(P)(A), Revision 1, Supplement 1, "Gadolinia Fuel Properties of LWR Fuel Safety Evaluation," November 1981." XN-NF-82-06(P)(A) and Supplements 2, 4, and 5, "Qualification of Exxon Nuclear Fuel for Extended Burnup," Revision 1, October 1986.* XN-NF-85-92(P)(A), "Exxon Nuclear Uranium Dioxide/Gadolinia Irradiation Examination and Thermal Conductivity Results," August 1985." ANF-88-133(P)(A) and Supplement 1, "Qualification of Advanced Nuclear Fuels PWR Design Methodology for Rod Burnups of 62 GWd/MTU," December 1991.* EMF-92-116(P)(A), "Generic Mechanical Design Criteria for PWR Fuel Designs," Revision 0, February 1999." XN-NF-78-44(P)(A), "A Generic Analysis of the Control Rod Ejection Transient for Pressurized Water Reactors," October 1983.* XN-NF-82-21 (P)(A), "Application of Exxon Nuclear Company PWR Thermal Margin Methodology to Mixed Core Configurations," Revision 1, September 1983.* EMF-1 961 (P)(A), "Statistical Setpoint/Transient Methodology for Combustion Engineering Type Reactors," Revision 0, July 2000.* ANF-89-151 (P)(A), "ANF-RELAP Methodology for Pressurized Water Reactors: Analysis of Non-LOCA Chapter 15 Events," Revision 0, May 1992." EMF-92-153(P)(A), "HTP: Departure from Nucleate Boiling Correlation for High Thermal Performance Fuel," Revision 1, January 2005.* XN-NF-82-49(P)(A), Supplement 1, "Exxon Nuclear Company Evaluation Model Revised EXEM PWR Small Break Model," Revision 1, December 1994.* EMF-2103(P)(A), "Realistic Large Break LOCA Methodology for Pressurized Water Reactors," Revision 0, April 2003.* EMF-2328(P)(A), "PWR Small Break LOCA Evaluation Model, S-RELAP5 Based," Revision 0, March 2001.* EMF-96-029(P)(A)
: 2. CORE OPERATING LIMITS All values and limits in this TDB section apply to Cycle 25 operation. This cycle must be operated within the bounds of these limits and all others specified in the Technical Specifications.
Volume 1, EMF-96-029(P)(A)
This report has been prepared in accordance with the requirements of Technical Specification 5.9.5. The list of references below are complete citations of topical reports and include the report number, title, revision, date, and any supplements in accordance with the basis for NRC approval of License Amendment No. 196 which eliminated these specific entries from Technical Specification 5.9.5. NRC approval of Amendment No. 196 is consistent with the requirements of the Technical Specification Task Force, Improved Standard Technical Specification Change Traveler, "Revise Topical Report References in ITS 5.6.5 COLR" (TSTF-363-A, Rev. 0). In accordance with this Traveler and Amendment No. 196, this information must be maintained within this TDB section.
Volume 2, EMF-96-029(P)(A)
R38
Attachment, "Reactor Analysis System for PWRs, Volume 1 -Methodology Description, Volume 2 -Benchmarking Results," January 1997.* EMF-2310(P)(A), "SRP Chapter 15 Non-LOCA Methodology for Pressurized Water Reactors," Revision 1, May 2004.* BAW-10240(P)(A), "Incorporation of M5TM Properties in Framatome ANP Approved Methods," Revision 0, May 2004.R38 FORT CALHOUN STATION TECHNICAL DATA BOOK TDB-VI PAGE 8 OF 19 3. TM/LP LIMIT The TM/LP coefficients are shown below: Table 1 -TM/LP Coefficients Coefficient a 13 Value 29.6 20.63-12372 The TM/LP setpoint is calculated by the PVAR equation, shown below and in Figure 1: PVAR = 29.6 PF(B) AI(Y)B + 20.63TIN -12372 PF(B) = 1.0= -0.008(B)+1.8
 
= 1.4 AI(Y) = -0.6666(Y 1) + 1.000-= +0.3333(Yi)  
FORT CALHOUN STATION                                                                   TDB-VI TECHNICAL DATA BOOK                                                           PAGE 7 OF 19 The values and limits presented within this TDB section have been derived using the NRC approved methodologies listed below:
+ 1.000 for B > 100%for 50% < B < 100%for B _ 50%for Y 1 -< 0.00 for Y 1> 0.00 Where: B = High Auctioneered thermal (AT) or Nuclear Power, % of rated power Y = Axial Shape Index, asiu TIN = Core Inlet Temperature, OF PVAR = Reactor Coolant System Pressure, psia 4. MAXIMUM CORE INLET TEMPERATURE The maximum core inlet temperature (TIN) shall not exceed 545 0 F. This value includes instrumentation uncertainty of +/-2 0 F (Ref: FCS Calculation FC06292, 6/9/95).This limit is not applicable during either a thermal power ramp in excess of 5% of rated thermal power per minute or a thermal power step greater than 10% of rated thermal power.5. POWER DEPENDENT INSERTION LIMIT The power dependent insertion limit is defined in Figure 2.R38 FORT CALHOUN STATION TECHNICAL DATA BOOK TDB-VI PAGE 9 OF 19 6. LINEAR HEAT RATE The allowable peak linear heat rate is shown in Figure 3.7. EXCORE MONITORING OF LHR The allowable operation for power versus axial shape index for monitoring of LHR with excore detectors is shown in Figure 4.8. PEAKING FACTOR LIMITS The maximum full power value for the integrated radial peaking factor (FRT) is 1.732.9. DNB MONITORING The core operating limits for monitoring of DNB are provided in Figure 5. This figure provides the allowable power versus axial shape index for the cycle.10. FRT AND CORE POWER LIMITATIONS Core power limitations versus FRT are shown in Figure 6.11. REFUELING BORON CONCENTRATION The refueling boron concentration is required to ensure a shutdown margin of not less than 5% with all CEAs withdrawn.
* OPPD-NA-8301, "Reload Core Analysis Methodology Overview," Revision 8, dated August 2004. (TAC No. MC4304)
The refueling boron concentration must be at least 1,900 ppm through the end of Cycle 24 operation and is valid until the beginning of core reload for Cycle 25.Listed below in Table 2 are the refueling boron concentration values for Cycle 25 operations:
* OPPD-NA-8302, "Reload Core Analysis Methodology, Neutronics Design Methods and Verification," Revision 6, dated August 2004. (TAC No. MC4304)
Table 2 -Refueling Boron Concentrations Cycle Average Burnup (MWD/MTU)BOC> 2,000>4,000 Refueling Boron Concentration (ppm)2,141 2,014 1,900 R38 FORT CALHOUN STATION TDB-VI TECHNICAL DATA BOOK PAGE 10 OF 19 12. AXIAL POWER DISTRIBUTION The axial power trip is provided to ensure that excessive axial peaking will not cause fuel damage. The Axial Shape Index is determined from the axially split excore detectors.
    " OPPD-NA-8303, "Reload Core Analysis Methodology, Transient and Accident Methods and Verification," Revision 7, dated August 2005. (TAC No. MC4304)
The setpoint functions, shown in Figure 7 ensure that neither a DNBR of less than the minimum DNBR safety limit nor a fuel centerline temperature greater than the associated safety limit (that which would result in fuel melting) will exist as a consequence of axial power maldistributions.
    " XN-75-32(P)(A) Supplements 1, 2, 3, & 4, "Computational Procedure for Evaluating Fuel Rod Bowing," October 1983.
The calculated cycle-specific FCM temperature for Cycle 25 corresponds to 22.705 kw/ft. Allowances have been made for instrumentation inaccuracies and uncertainties associated with the excore symmetric offset -incore axial peaking relationship.
    " XN-NF-79-56(P)(A), Revision 1, Supplement 1, "Gadolinia Fuel Properties of LWR Fuel Safety Evaluation," November 1981.
Figure 8 combines the LHR LCO tent from Figure 4, the DNB LCO tent from Figure 5, and the APD LSSS tent from Figure 7 into one figure for a visual comparison of the different limits.13. SHUTDOWN MARGIN WITH Tcold>* 210&deg;F Whenever the reactor is in hot shutdown, hot standby or power operation conditions, the shutdown margin shall be _3.6% Ak/k. With the shutdown margin <3.6% Ak/k, initiate and continue boration until the required shutdown margin is achieved.14. MOST NEGATIVE MODERATOR TEMPERATURE COEFFICIENT The moderator temperature coefficient (MTC) shall be more positive than-3.30 x 10-4 Ap/0 F, including uncertainties, at rated power.15. STEAM GENERATOR DIFFERENTIAL PRESSURE The steam generator differential pressure trip of Technical Specification Table 2-11, Item 9 at 135 psid ensures that neither a DNBR of less than the minimum DNBR safety limit nor a fuel centerline temperature greater than the associated safety limit (that which would result in fuel melting) will exist as a consequence of axial power maldistributions resulting from asymmetric steam generator transients.
    " XN-NF-82-06(P)(A) and Supplements 2, 4, and 5, "Qualification of Exxon Nuclear Fuel for Extended Burnup," Revision 1, October 1986.
The calculated cycle-specific FCM temperature for Cycle 25 corresponds to 22.705 kw/ft.R38 FORT CALHOUN STATION TECHNICAL DATA BOOK TDB-VI PAGE 11 OF 19 R38 FORT CALHOUN STATION TECHNICAL DATA BOOK TDB-VI PAGE 12 OF 19 R38 FORT CALHOUN STATION TECHNICAL DATA BOOK TDB-VI PAGE 13 OF 19 18 16 14 LI..S12 w I-uJ&#xfd;z-0 w Z 6 4 2 UNACCEPTABLE OPERATION 15.5 KW/FT ACCEPTABLE OPERATION 44 4 4 4 t 4 0 5000 10000 15000 20000 BURNUP (MWD/MTU)COLR ALLOWABLE PEAK LINEAR HEAT RATE FIGURE ALWBEVS. BURNUP1 3 R38 FORT CALHOUN STATION TECHNICAL DATA BOOK TDB-VI PAGE 14 OF 19 R38 FORT CALHOUN STATION TECHNICAL DATA BOOK TDB-VI PAGE 15 OF 19 R38 FORT CALHOUN STATION TECHNICAL DATA BOOK TDB-VI PAGE 16 OF 19 R38 FORT CALHOUN STATION TECHNICAL DATA BOOK TDB-VI PAGE 17 OF 19 R38 FORT CALHOUN STATION TECHNICAL DATA BOOK TDB-VI PAGE 18 OF 19 R38 FORT CALHOUN STATION TECHNICAL DATA BOOK TDB-VI PAGE 19 OF 19 R38}}
* XN-NF-85-92(P)(A), "Exxon Nuclear Uranium Dioxide/Gadolinia Irradiation Examination and Thermal Conductivity Results," August 1985.
    " ANF-88-133(P)(A) and Supplement 1, "Qualification of Advanced Nuclear Fuels PWR Design Methodology for Rod Burnups of 62 GWd/MTU," December 1991.
* EMF-92-116(P)(A), "Generic Mechanical Design Criteria for PWR Fuel Designs,"
Revision 0, February 1999.
    " XN-NF-78-44(P)(A), "A Generic Analysis of the Control Rod Ejection Transient for Pressurized Water Reactors," October 1983.
* XN-NF-82-21 (P)(A), "Application of Exxon Nuclear Company PWR Thermal Margin Methodology to Mixed Core Configurations," Revision 1, September 1983.
* EMF-1 961 (P)(A), "Statistical Setpoint/Transient Methodology for Combustion Engineering Type Reactors," Revision 0, July 2000.
* ANF-89-151 (P)(A), "ANF-RELAP Methodology for Pressurized Water Reactors:
Analysis of Non-LOCA Chapter 15 Events," Revision 0, May 1992.
    " EMF-92-153(P)(A), "HTP: Departure from Nucleate Boiling Correlation for High Thermal Performance Fuel," Revision 1, January 2005.
* XN-NF-82-49(P)(A), Supplement 1, "Exxon Nuclear Company Evaluation Model Revised EXEM PWR Small Break Model," Revision 1, December 1994.
* EMF-2103(P)(A), "Realistic Large Break LOCA Methodology for Pressurized Water Reactors," Revision 0, April 2003.
* EMF-2328(P)(A), "PWR Small Break LOCA Evaluation Model, S-RELAP5 Based,"
Revision 0, March 2001.
* EMF-96-029(P)(A) Volume 1, EMF-96-029(P)(A) Volume 2, EMF-96-029(P)(A)
Attachment, "Reactor Analysis System for PWRs, Volume 1 - Methodology Description, Volume 2 - Benchmarking Results," January 1997.
* EMF-2310(P)(A), "SRP Chapter 15 Non-LOCA Methodology for Pressurized Water Reactors," Revision 1, May 2004.
* BAW-10240(P)(A), "Incorporation of M5TM Properties in Framatome ANP Approved Methods," Revision 0, May 2004.
R38
 
FORT CALHOUN STATION                                                                     TDB-VI TECHNICAL DATA BOOK                                                               PAGE 8 OF 19
: 3. TM/LP LIMIT The TM/LP coefficients are shown below:
Table 1 -TM/LP Coefficients Coefficient                     Value a                           29.6 20.63 13
                                                      -12372 The TM/LP setpoint is calculated by the PVAR equation, shown below and in Figure 1:
PVAR = 29.6 PF(B) AI(Y)B + 20.63TIN - 12372 PF(B) = 1.0                           for B > 100%
                                  = -0.008(B)+1.8                 for 50% < B < 100%
                                  = 1.4                           for B _ 50%
AI(Y) = -0.6666(Y1 ) + 1.000           for Y1 -<0.00
                                  -= +0.3333(Yi) + 1.000         for Y1 > 0.00 Where:
B = High Auctioneered thermal (AT) or Nuclear Power, % of rated power Y = Axial Shape Index, asiu TIN = Core Inlet Temperature, OF PVAR = Reactor Coolant System Pressure, psia
: 4. MAXIMUM CORE INLET TEMPERATURE The maximum core inlet temperature (TIN) shall not exceed 5450 F. This value includes instrumentation uncertainty of +/-20 F (Ref: FCS Calculation FC06292, 6/9/95).
This limit is not applicable during either a thermal power ramp in excess of 5% of rated thermal power per minute or a thermal power step greater than 10% of rated thermal power.
: 5. POWER DEPENDENT INSERTION LIMIT The power dependent insertion limit is defined in Figure 2.
R38
 
FORT CALHOUN STATION                                                                   TDB-VI TECHNICAL DATA BOOK                                                             PAGE 9 OF 19
: 6. LINEAR HEAT RATE The allowable peak linear heat rate is shown in Figure 3.
: 7. EXCORE MONITORING OF LHR The allowable operation for power versus axial shape index for monitoring of LHR with excore detectors is shown in Figure 4.
: 8. PEAKING FACTOR LIMITS The maximum full power value for the integrated radial peaking factor (FRT) is 1.732.
: 9. DNB MONITORING The core operating limits for monitoring of DNB are provided in Figure 5. This figure provides the allowable power versus axial shape index for the cycle.
: 10. FRT AND CORE POWER LIMITATIONS Core power limitations versus FRT are shown in Figure 6.
: 11. REFUELING BORON CONCENTRATION The refueling boron concentration is required to ensure a shutdown margin of not less than 5% with all CEAs withdrawn. The refueling boron concentration must be at least 1,900 ppm through the end of Cycle 24 operation and is valid until the beginning of core reload for Cycle 25.
Listed below in Table 2 are the refueling boron concentration values for Cycle 25 operations:
Table 2 - Refueling Boron Concentrations Cycle Average Burnup                 Refueling Boron (MWD/MTU)                     Concentration (ppm)
BOC                             2,141
                          > 2,000                           2,014
                          >4,000                           1,900 R38
 
FORT CALHOUN STATION                                                                       TDB-VI TECHNICAL DATA BOOK                                                               PAGE 10 OF 19
: 12. AXIAL POWER DISTRIBUTION The axial power trip is provided to ensure that excessive axial peaking will not cause fuel damage. The Axial Shape Index is determined from the axially split excore detectors.
The setpoint functions, shown in Figure 7 ensure that neither a DNBR of less than the minimum DNBR safety limit nor a fuel centerline temperature greater than the associated safety limit (that which would result in fuel melting) will exist as a consequence of axial power maldistributions. The calculated cycle-specific FCM temperature for Cycle 25 corresponds to 22.705 kw/ft. Allowances have been made for instrumentation inaccuracies and uncertainties associated with the excore symmetric offset - incore axial peaking relationship. Figure 8 combines the LHR LCO tent from Figure 4, the DNB LCO tent from Figure 5, and the APD LSSS tent from Figure 7 into one figure for a visual comparison of the different limits.
: 13. SHUTDOWN MARGIN WITH             Tcold>* 210&deg;F Whenever the reactor is in hot shutdown, hot standby or power operation conditions, the shutdown margin shall be _3.6% Ak/k. With the shutdown margin <3.6% Ak/k, initiate and continue boration until the required shutdown margin is achieved.
: 14. MOST NEGATIVE MODERATOR TEMPERATURE COEFFICIENT The moderator temperature coefficient (MTC) shall be more positive than
    -3.30 x 10-4 Ap/ 0 F, including uncertainties, at rated power.
: 15. STEAM GENERATOR DIFFERENTIAL PRESSURE The steam generator differential pressure trip of Technical Specification Table 2-11, Item 9 at 135 psid ensures that neither a DNBR of less than the minimum DNBR safety limit nor a fuel centerline temperature greater than the associated safety limit (that which would result in fuel melting) will exist as a consequence of axial power maldistributions resulting from asymmetric steam generator transients. The calculated cycle-specific FCM temperature for Cycle 25 corresponds to 22.705 kw/ft.
R38
 
FORT CALHOUN STATION       TDB-VI TECHNICAL DATA BOOK PAGE 11 OF 19 R38
 
FORT CALHOUN STATION       TDB-VI TECHNICAL DATA BOOK PAGE 12 OF 19 R38
 
FORT CALHOUN STATION                                           TDB-VI TECHNICAL DATA BOOK                                     PAGE 13 OF 19 18 UNACCEPTABLE OPERATION 16 15.5 KW/FT 14 LI..                   ACCEPTABLE OPERATION S12 w
I-
        -0
        &#xfd;z wuJ 44 Z
6               4         4         4 4               t         4 2
0           5000     10000     15000 20000 BURNUP (MWD/MTU)
COLR             ALLOWABLE PEAK LINEAR HEAT RATE FIGURE ALWBEVS. BURNUP1                   3 R38
 
FORT CALHOUN STATION       TDB-VI TECHNICAL DATA BOOK PAGE 14 OF 19 R38
 
FORT CALHOUN STATION       TDB-VI TECHNICAL DATA BOOK PAGE 15 OF 19 R38
 
FORT CALHOUN STATION       TDB-VI TECHNICAL DATA BOOK PAGE 16 OF 19 R38
 
FORT CALHOUN STATION       TDB-VI TECHNICAL DATA BOOK PAGE 17 OF 19 R38
 
FORT CALHOUN STATION       TDB-VI TECHNICAL DATA BOOK PAGE 18 OF 19 R38
 
FORT CALHOUN STATION       TDB-VI TECHNICAL DATA BOOK PAGE 19 OF 19 R38}}

Latest revision as of 03:06, 14 November 2019

Transmittal of Fort Calhoun Station (Fcs), Unit 1, Core Operating Limit Report (Colr), Revision 38
ML092650388
Person / Time
Site: Fort Calhoun Omaha Public Power District icon.png
Issue date: 09/14/2009
From: Matthews T
Omaha Public Power District
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
LIC-09-0074
Download: ML092650388 (20)


Text

OmahaPublic Power District Fort Calhoun Station P.O. Box 550, Fort Calhoun, NE 68023 September 14, 2009 LIC-09-0074 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555

Reference:

Docket No. 50-285

SUBJECT:

Transmittal of Fort Calhoun Station (FCS), Unit No. 1, Core Operating Limit Report (COLR), Revision 38 Pursuant to FCS Technical Specification 5.9.5d, Revision 38 of the FCS COLR is attached. Revision 38, issued on September 1, 2009, revised the Cycle 25 fuel centerline melt limit from 23.416 kw/ft to 22.705 kw/ft.

No regulatory commitments are contained in this submittal.

If you have any questions, please contact Ms. Susan Baughn at (402) 533-7215.

Sincerely, T. C. Matthews Manager - Nuclear Licensing TCM/mle

Attachment:

TDB-VI - Technical Data Book - Core Operating Limit Report - Revision 38 c: E. E. Collins, NRC Regional Administrator, Region IV (w/o Attachment)

A. B. Wang, NRC Project Manager (w/o Attachment)

J. C. Kirkland, NRC Senior Resident Inspector (w/o Attachment)

Employment with Equal Opportunity

PAGE 1 OF 19 Fort Calhoun Station Unit 1 TDB-VI TECHNICAL DATA BOOK CORE OPERATING LIMIT REPORT Change No. EC 46602 Reason for Change Revised Cycle 25 Fuel Centerline Melt Limit from 23.416 kw/ft to 22.705 kw/ft.

Requestor C. Waszak Preparer L. Hautzinger Issue Date 09-01-09 3:00 pm R38

FORT CALHOUN STATION TDB-VI TECHNICAL DATA BOOK PAGE 2 OF 19 Fort Calhoun Station, Unit 1 Core Operating Limit Report Due to the critical aspects of the safety analysis inputs contained in this report, changes may not be made to this report without concurrence of the Nuclear Engineering Department.

R38

FORT CALHOUN STATION TDB-VI TECHNICAL DATA BOOK PAGE 3 OF 19 TABLE OF CONTENTS Item Description Pagqe

1. IN T R O D UC T IO N ............................................................................................ 6
2. CO RE O PERATING LIM ITS ........................................................................... 6
3. T M/LP LIM IT ...................... I......................................................................... .. 8
4. MAXIMUM CORE INLET TEMPERATURE .................................................... 8
5. POWER DEPENDENT INSERTION LIMIT .................................................... 8
6. LIN EA R HEA T RA TE ...................................................................................... 9
7. EXCORE MONITORING OF LHR ................................................................... 9
8. PEA KING FACTO R LIM ITS ........................................................................... 9
9. D N B MO NIT O R IN G ........................................................................................ 9
10. FRT AND CORE POWER LIMITATIONS ........................................................ 9
11. REFUELING BORON CONCENTRATION ...................................................... 9
12. AXIAL POWER DISTRIBUTION .................................................................. 10
13. SHUTDOWN MARGIN WITH Tcold > 210-F ................................................. 10
14. MOST NEGATIVE MODERATOR TEMPERATURE COEFFICIENT ............ 10
15. STEAM GENERATOR DIFFERENTIAL PRESSURE ................................... 10 R38

FORT CALHOUN STATION TDB-VI TECHNICAL DATA BOOK PAGE 4 OF 19 LIST OF TABLES Table No. Title Page 1 T M/LP C oeffi cients .......................................................................................... 8 2 Refueling Boron Concentrations ..................................................................... 9 R38

FORT CALHOUN STATION TDB-VI TECHNICAL DATA BOOK PAGE 5 OF 19 LIST OF FIGURES Figure No. Title Page 1 Thermal Margin/Low Pressure for 4 Pump Operation ..................................... 11 2 Power Dependent Insertion Limit ................................................................... 12 3 Allowable Peak Linear Heat Rate vs. Burnup ................................................ 13 4 Excore Monitoring of LH R ................................................................................ 14 5 D N B Mo nito ring ............................................................................................ . . 15 6 FRT and Core Power Limitations .................................................................... 16 7 Axial Power Distribution LSSS for 4 Pump Operation ..................................... 17 8 Axial Power Distribution Limits for 4 Pump Operation with Incores Inoperable.. 18 9 Minimum Boric Acid Storage Tank Level vs. Stored Boric Acid Storage Tank C o nce ntratio n ................................................................................................ .. 19 R38

FORT CALHOUN STATION TDB-VI TECHNICAL DATA BOOK PAGE 6 OF 19 CORE OPERATING LIMIT REPORT

1. INTRODUCTION This report provides the cycle-specific limits for operation of the Fort Calhoun Station Unit 1 for Cycle 25 operation. It includes limits for:
  • TM/LP LSSS for 4 Pump Operation (PVAR)

" Core Inlet Temperature (TIN)

  • Power Dependent Insertion Limit (PDIL)
  • Allowable Peak Linear Heat Rate
  • Excore Monitoring of LHR
  • Integrated Radial Peaking Factor (FRT)
  • FRT versus Power Trade-off Curve

" Refueling Boron Concentration

" Axial Power Distribution (APD)

  • Most Negative Moderator Temperature Coefficient These limits are applicable for the duration of the cycle. For subsequent cycles the limits will be reviewed and revised as necessary. In addition, this report includes a number of cycle-specific coefficients used in the generation of certain reactor protective system trip setpoints or allowable increases in radial peaking factors.
2. CORE OPERATING LIMITS All values and limits in this TDB section apply to Cycle 25 operation. This cycle must be operated within the bounds of these limits and all others specified in the Technical Specifications.

This report has been prepared in accordance with the requirements of Technical Specification 5.9.5. The list of references below are complete citations of topical reports and include the report number, title, revision, date, and any supplements in accordance with the basis for NRC approval of License Amendment No. 196 which eliminated these specific entries from Technical Specification 5.9.5. NRC approval of Amendment No. 196 is consistent with the requirements of the Technical Specification Task Force, Improved Standard Technical Specification Change Traveler, "Revise Topical Report References in ITS 5.6.5 COLR" (TSTF-363-A, Rev. 0). In accordance with this Traveler and Amendment No. 196, this information must be maintained within this TDB section.

R38

FORT CALHOUN STATION TDB-VI TECHNICAL DATA BOOK PAGE 7 OF 19 The values and limits presented within this TDB section have been derived using the NRC approved methodologies listed below:

  • OPPD-NA-8301, "Reload Core Analysis Methodology Overview," Revision 8, dated August 2004. (TAC No. MC4304)
  • OPPD-NA-8302, "Reload Core Analysis Methodology, Neutronics Design Methods and Verification," Revision 6, dated August 2004. (TAC No. MC4304)

" OPPD-NA-8303, "Reload Core Analysis Methodology, Transient and Accident Methods and Verification," Revision 7, dated August 2005. (TAC No. MC4304)

" XN-75-32(P)(A) Supplements 1, 2, 3, & 4, "Computational Procedure for Evaluating Fuel Rod Bowing," October 1983.

" XN-NF-79-56(P)(A), Revision 1, Supplement 1, "Gadolinia Fuel Properties of LWR Fuel Safety Evaluation," November 1981.

" XN-NF-82-06(P)(A) and Supplements 2, 4, and 5, "Qualification of Exxon Nuclear Fuel for Extended Burnup," Revision 1, October 1986.

  • XN-NF-85-92(P)(A), "Exxon Nuclear Uranium Dioxide/Gadolinia Irradiation Examination and Thermal Conductivity Results," August 1985.

" ANF-88-133(P)(A) and Supplement 1, "Qualification of Advanced Nuclear Fuels PWR Design Methodology for Rod Burnups of 62 GWd/MTU," December 1991.

  • EMF-92-116(P)(A), "Generic Mechanical Design Criteria for PWR Fuel Designs,"

Revision 0, February 1999.

" XN-NF-78-44(P)(A), "A Generic Analysis of the Control Rod Ejection Transient for Pressurized Water Reactors," October 1983.

  • XN-NF-82-21 (P)(A), "Application of Exxon Nuclear Company PWR Thermal Margin Methodology to Mixed Core Configurations," Revision 1, September 1983.
  • EMF-1 961 (P)(A), "Statistical Setpoint/Transient Methodology for Combustion Engineering Type Reactors," Revision 0, July 2000.
  • ANF-89-151 (P)(A), "ANF-RELAP Methodology for Pressurized Water Reactors:

Analysis of Non-LOCA Chapter 15 Events," Revision 0, May 1992.

" EMF-92-153(P)(A), "HTP: Departure from Nucleate Boiling Correlation for High Thermal Performance Fuel," Revision 1, January 2005.

  • XN-NF-82-49(P)(A), Supplement 1, "Exxon Nuclear Company Evaluation Model Revised EXEM PWR Small Break Model," Revision 1, December 1994.
  • EMF-2103(P)(A), "Realistic Large Break LOCA Methodology for Pressurized Water Reactors," Revision 0, April 2003.
  • EMF-2328(P)(A), "PWR Small Break LOCA Evaluation Model, S-RELAP5 Based,"

Revision 0, March 2001.

  • EMF-96-029(P)(A) Volume 1, EMF-96-029(P)(A) Volume 2, EMF-96-029(P)(A)

Attachment, "Reactor Analysis System for PWRs, Volume 1 - Methodology Description, Volume 2 - Benchmarking Results," January 1997.

  • EMF-2310(P)(A), "SRP Chapter 15 Non-LOCA Methodology for Pressurized Water Reactors," Revision 1, May 2004.
  • BAW-10240(P)(A), "Incorporation of M5TM Properties in Framatome ANP Approved Methods," Revision 0, May 2004.

R38

FORT CALHOUN STATION TDB-VI TECHNICAL DATA BOOK PAGE 8 OF 19

3. TM/LP LIMIT The TM/LP coefficients are shown below:

Table 1 -TM/LP Coefficients Coefficient Value a 29.6 20.63 13

-12372 The TM/LP setpoint is calculated by the PVAR equation, shown below and in Figure 1:

PVAR = 29.6 PF(B) AI(Y)B + 20.63TIN - 12372 PF(B) = 1.0 for B > 100%

= -0.008(B)+1.8 for 50% < B < 100%

= 1.4 for B _ 50%

AI(Y) = -0.6666(Y1 ) + 1.000 for Y1 -<0.00

-= +0.3333(Yi) + 1.000 for Y1 > 0.00 Where:

B = High Auctioneered thermal (AT) or Nuclear Power, % of rated power Y = Axial Shape Index, asiu TIN = Core Inlet Temperature, OF PVAR = Reactor Coolant System Pressure, psia

4. MAXIMUM CORE INLET TEMPERATURE The maximum core inlet temperature (TIN) shall not exceed 5450 F. This value includes instrumentation uncertainty of +/-20 F (Ref: FCS Calculation FC06292, 6/9/95).

This limit is not applicable during either a thermal power ramp in excess of 5% of rated thermal power per minute or a thermal power step greater than 10% of rated thermal power.

5. POWER DEPENDENT INSERTION LIMIT The power dependent insertion limit is defined in Figure 2.

R38

FORT CALHOUN STATION TDB-VI TECHNICAL DATA BOOK PAGE 9 OF 19

6. LINEAR HEAT RATE The allowable peak linear heat rate is shown in Figure 3.
7. EXCORE MONITORING OF LHR The allowable operation for power versus axial shape index for monitoring of LHR with excore detectors is shown in Figure 4.
8. PEAKING FACTOR LIMITS The maximum full power value for the integrated radial peaking factor (FRT) is 1.732.
9. DNB MONITORING The core operating limits for monitoring of DNB are provided in Figure 5. This figure provides the allowable power versus axial shape index for the cycle.
10. FRT AND CORE POWER LIMITATIONS Core power limitations versus FRT are shown in Figure 6.
11. REFUELING BORON CONCENTRATION The refueling boron concentration is required to ensure a shutdown margin of not less than 5% with all CEAs withdrawn. The refueling boron concentration must be at least 1,900 ppm through the end of Cycle 24 operation and is valid until the beginning of core reload for Cycle 25.

Listed below in Table 2 are the refueling boron concentration values for Cycle 25 operations:

Table 2 - Refueling Boron Concentrations Cycle Average Burnup Refueling Boron (MWD/MTU) Concentration (ppm)

BOC 2,141

> 2,000 2,014

>4,000 1,900 R38

FORT CALHOUN STATION TDB-VI TECHNICAL DATA BOOK PAGE 10 OF 19

12. AXIAL POWER DISTRIBUTION The axial power trip is provided to ensure that excessive axial peaking will not cause fuel damage. The Axial Shape Index is determined from the axially split excore detectors.

The setpoint functions, shown in Figure 7 ensure that neither a DNBR of less than the minimum DNBR safety limit nor a fuel centerline temperature greater than the associated safety limit (that which would result in fuel melting) will exist as a consequence of axial power maldistributions. The calculated cycle-specific FCM temperature for Cycle 25 corresponds to 22.705 kw/ft. Allowances have been made for instrumentation inaccuracies and uncertainties associated with the excore symmetric offset - incore axial peaking relationship. Figure 8 combines the LHR LCO tent from Figure 4, the DNB LCO tent from Figure 5, and the APD LSSS tent from Figure 7 into one figure for a visual comparison of the different limits.

13. SHUTDOWN MARGIN WITH Tcold>* 210°F Whenever the reactor is in hot shutdown, hot standby or power operation conditions, the shutdown margin shall be _3.6% Ak/k. With the shutdown margin <3.6% Ak/k, initiate and continue boration until the required shutdown margin is achieved.
14. MOST NEGATIVE MODERATOR TEMPERATURE COEFFICIENT The moderator temperature coefficient (MTC) shall be more positive than

-3.30 x 10-4 Ap/ 0 F, including uncertainties, at rated power.

15. STEAM GENERATOR DIFFERENTIAL PRESSURE The steam generator differential pressure trip of Technical Specification Table 2-11, Item 9 at 135 psid ensures that neither a DNBR of less than the minimum DNBR safety limit nor a fuel centerline temperature greater than the associated safety limit (that which would result in fuel melting) will exist as a consequence of axial power maldistributions resulting from asymmetric steam generator transients. The calculated cycle-specific FCM temperature for Cycle 25 corresponds to 22.705 kw/ft.

R38

FORT CALHOUN STATION TDB-VI TECHNICAL DATA BOOK PAGE 11 OF 19 R38

FORT CALHOUN STATION TDB-VI TECHNICAL DATA BOOK PAGE 12 OF 19 R38

FORT CALHOUN STATION TDB-VI TECHNICAL DATA BOOK PAGE 13 OF 19 18 UNACCEPTABLE OPERATION 16 15.5 KW/FT 14 LI.. ACCEPTABLE OPERATION S12 w

I-

-0

ýz wuJ 44 Z

6 4 4 4 4 t 4 2

0 5000 10000 15000 20000 BURNUP (MWD/MTU)

COLR ALLOWABLE PEAK LINEAR HEAT RATE FIGURE ALWBEVS. BURNUP1 3 R38

FORT CALHOUN STATION TDB-VI TECHNICAL DATA BOOK PAGE 14 OF 19 R38

FORT CALHOUN STATION TDB-VI TECHNICAL DATA BOOK PAGE 15 OF 19 R38

FORT CALHOUN STATION TDB-VI TECHNICAL DATA BOOK PAGE 16 OF 19 R38

FORT CALHOUN STATION TDB-VI TECHNICAL DATA BOOK PAGE 17 OF 19 R38

FORT CALHOUN STATION TDB-VI TECHNICAL DATA BOOK PAGE 18 OF 19 R38

FORT CALHOUN STATION TDB-VI TECHNICAL DATA BOOK PAGE 19 OF 19 R38