Line 3: |
Line 3: |
| | issue date = 04/11/2012 | | | issue date = 04/11/2012 |
| | title = Supplemental Response to Request for Additional Information Related to the Proposed Administrative Changes to the Technical Specifications | | | title = Supplemental Response to Request for Additional Information Related to the Proposed Administrative Changes to the Technical Specifications |
| | author name = Jesse M D | | | author name = Jesse M |
| | author affiliation = Exelon Generation Co, LLC, Exelon Nuclear | | | author affiliation = Exelon Generation Co, LLC, Exelon Nuclear |
| | addressee name = | | | addressee name = |
Line 26: |
Line 26: |
| ==References:== | | ==References:== |
|
| |
|
| (1)Letter from P.Bamford (U.S.Nuclear Regulatory Commission) to M.J.Padlio (Exelon Generation Company, LLC),"Three Mile Island Nuclear Station, Unit 1 Request for Additional Information Regarding Proposed License Amendment Revising Technical Specifications to Incorporate Administrative Changes" (TAC NO.ME7357)" dated December 19, 2011 (ML 113360596) | | (1)Letter from P.Bamford (U.S.Nuclear Regulatory Commission) to M.J.Padlio (Exelon Generation Company, LLC),"Three Mile Island Nuclear Station, Unit 1 Request for Additional Information Regarding Proposed License Amendment Revising Technical Specifications to Incorporate Administrative Changes" (TAC NO.ME7357)" dated December 19, 2011 (ML113360596) |
| Letter from M.D.Jesse (Exelon Generation Company, LLC)to U.S.Nuclear Regulatory Commission,'Three Mile Island Unit 1 Response to Request for Additional Information Related to Proposed Administrative Changes to the Technical Specifications" dated January 20,2012 (ML 12020A091) | | Letter from M.D.Jesse (Exelon Generation Company, LLC)to U.S.Nuclear Regulatory Commission,'Three Mile Island Unit 1 Response to Request for Additional Information Related to Proposed Administrative Changes to the Technical Specifications" dated January 20,2012 (ML12020A091) |
| USNRC request for additional information (RAI), Reference 1, included several observations regarding the eXisting Three Mile Island, Unit 1 (TMI, Unit 1)Technical Specifications (TSs).The observations included the following statement: | | USNRC request for additional information (RAI), Reference 1, included several observations regarding the eXisting Three Mile Island, Unit 1 (TMI, Unit 1)Technical Specifications (TSs).The observations included the following statement: |
| "...the NRC staff notes that TS 5.1.1 refers to a"weather tower" depicted on Figure 5-3.Both the existing and revised Figure 5-3 depictions show a"weather station." Exelon should consider making this terminology consistent." In the Reference 2 RAI response, TMI, Unit 1 requested a revision to TS 5.1.1 on page 5-1 to state"weather station" consistent with Figure 5-3 and the NRC observation. | | "...the NRC staff notes that TS 5.1.1 refers to a"weather tower" depicted on Figure 5-3.Both the existing and revised Figure 5-3 depictions show a"weather station." Exelon should consider making this terminology consistent." In the Reference 2 RAI response, TMI, Unit 1 requested a revision to TS 5.1.1 on page 5-1 to state"weather station" consistent with Figure 5-3 and the NRC observation. |
Line 33: |
Line 33: |
| Therefore, TMI, Unit 1 withdraws the request to update TS 5.1.1 on page 5-1 to state"weather station" in the Reference 2 submittal. | | Therefore, TMI, Unit 1 withdraws the request to update TS 5.1.1 on page 5-1 to state"weather station" in the Reference 2 submittal. |
| Attachment 1 provides the revised TS page mark-ups showing the withdrawn change.Attachment 2 provides the revised page showing the proposed changes. | | Attachment 1 provides the revised TS page mark-ups showing the withdrawn change.Attachment 2 provides the revised page showing the proposed changes. |
| U.S.Nuclear Regulatory Commission April 11, 2012 2 TMI, Unit 1 has determined that the information provided in response to this request for additional information does not impact the conclusions of the No Significant Hazards Consideration or Environmental Consideration as stated in the original submittal dated October 18, 2011 (ML 112911548). | | U.S.Nuclear Regulatory Commission April 11, 2012 2 TMI, Unit 1 has determined that the information provided in response to this request for additional information does not impact the conclusions of the No Significant Hazards Consideration or Environmental Consideration as stated in the original submittal dated October 18, 2011 (ML112911548). |
| Additionally, there are no regulatory commitments contained in this submittal. | | Additionally, there are no regulatory commitments contained in this submittal. |
| Should you have any questions concerning this letter, ple,::lse contact Ms.Wendy Croft at (610)765-5726.I declare under penalty of perjury that the foregoing is true and correct.Executed on the 11 th day of April,2012. | | Should you have any questions concerning this letter, ple,::lse contact Ms.Wendy Croft at (610)765-5726.I declare under penalty of perjury that the foregoing is true and correct.Executed on the 11 th day of April,2012. |
Letter Sequence Supplement |
---|
|
|
|
|
---|
Category:Letter type:TMI
MONTHYEARTMI-24-007, Re 2023 Commitment Revision Summary Report2024-04-29029 April 2024 Re 2023 Commitment Revision Summary Report TMI-23-018, Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation2023-11-22022 November 2023 Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation TMI-23-013, Radiological Emergency Plan Document Revision2023-05-30030 May 2023 Radiological Emergency Plan Document Revision TMI-23-009, Submittal of Changes to Technical Specifications Bases2023-04-13013 April 2023 Submittal of Changes to Technical Specifications Bases TMI-23-004, Updated Site-Specific Decommissioning Cost Estimate for Three Mile Island Nuclear Station, Unit 12023-03-21021 March 2023 Updated Site-Specific Decommissioning Cost Estimate for Three Mile Island Nuclear Station, Unit 1 TMI-23-005, Updated Spent Fuel Management Plan2023-03-21021 March 2023 Updated Spent Fuel Management Plan TMI-23-002, Radiological Emergency Plan Document Revision2023-02-23023 February 2023 Radiological Emergency Plan Document Revision TMI-22-028, Radiological Emergency Plan Document Revisions2022-09-27027 September 2022 Radiological Emergency Plan Document Revisions TMI-22-016, 2021 Annual Radiological Effluent Release Report2022-04-25025 April 2022 2021 Annual Radiological Effluent Release Report TMI-22-017, 2021 Annual Radiological Environmental Operating Report2022-04-25025 April 2022 2021 Annual Radiological Environmental Operating Report TMI-22-018, 10 CFR 20.2206(b) Personnel Radiation Exposure Report for 20212022-04-19019 April 2022 10 CFR 20.2206(b) Personnel Radiation Exposure Report for 2021 TMI-22-015, Submittal of Changes to Technical Specifications Bases2022-04-13013 April 2022 Submittal of Changes to Technical Specifications Bases TMI-22-009, Registration of Use of Casks to Store Spent Fuel2022-03-0909 March 2022 Registration of Use of Casks to Store Spent Fuel TMI-22-008, 2021 Aircraft Movement Data Annual Report for TMI-12022-02-28028 February 2022 2021 Aircraft Movement Data Annual Report for TMI-1 TMI-22-004, Registration of Use of Casks to Store Spent Fuel2022-02-0606 February 2022 Registration of Use of Casks to Store Spent Fuel TMI-21-027, Supplement to License Amendment Request - Proposed Changes to the Three Mile Island Emergency Plan for Independent Spent Fuel Storage Installation Only Emergency Plan and Emergency Action Level Scheme2021-08-30030 August 2021 Supplement to License Amendment Request - Proposed Changes to the Three Mile Island Emergency Plan for Independent Spent Fuel Storage Installation Only Emergency Plan and Emergency Action Level Scheme TMI-21-024, 90-Day Notification Prior to First Storage of Spent Fuel2021-06-15015 June 2021 90-Day Notification Prior to First Storage of Spent Fuel TMI-21-025, Notification Pursuant to 10 CFR 72.140(d) of Intent to Apply Previously Approved 10 CFR 50, Appendix B, Quality Assurance Program to Independent Spent Fuel Storage Installation Activities2021-06-15015 June 2021 Notification Pursuant to 10 CFR 72.140(d) of Intent to Apply Previously Approved 10 CFR 50, Appendix B, Quality Assurance Program to Independent Spent Fuel Storage Installation Activities TMI-21-026, Demonstration of Compliance with NRC Order EA-20-103, Issuance of Order for Implementation of Additional Security Measures & Fingerprinting for Unescorted Access at Independent Spent Fuel Storage Installation2021-06-15015 June 2021 Demonstration of Compliance with NRC Order EA-20-103, Issuance of Order for Implementation of Additional Security Measures & Fingerprinting for Unescorted Access at Independent Spent Fuel Storage Installation TMI-21-018, License Amendment Request - Revised Three Mile Island Nuclear Station License in Support of Independent Spent Fuel Storage Installation (ISFSI) Only Security Plan2021-04-29029 April 2021 License Amendment Request - Revised Three Mile Island Nuclear Station License in Support of Independent Spent Fuel Storage Installation (ISFSI) Only Security Plan TMI-21-019, Submittal of 2020 Annual Radiological Environmental Operating Report2021-04-27027 April 2021 Submittal of 2020 Annual Radiological Environmental Operating Report TMI-21-017, Submittal of 2020 Annual Radiological Effluent Release Report2021-04-27027 April 2021 Submittal of 2020 Annual Radiological Effluent Release Report TMI-21-021, (TMI-1) and Unit 2 (TMI-2) - 10 CFR 20.2206(b) Personnel Radiation Exposure Report for 20202021-04-27027 April 2021 (TMI-1) and Unit 2 (TMI-2) - 10 CFR 20.2206(b) Personnel Radiation Exposure Report for 2020 TMI-21-009, License Amendment Request - Proposed Changes to the Three Mile Island Emergency Plan for Independent Spent Fuel Storage Installation Only Emergency Plan and Emergency Action Level Scheme2021-03-0404 March 2021 License Amendment Request - Proposed Changes to the Three Mile Island Emergency Plan for Independent Spent Fuel Storage Installation Only Emergency Plan and Emergency Action Level Scheme TMI-20-027, Request for Rescission of Security and Safeguards Order EA-02-026 ICM B.1.a from Three Mile Island Nuclear Station Renewed Facility License2020-10-0909 October 2020 Request for Rescission of Security and Safeguards Order EA-02-026 ICM B.1.a from Three Mile Island Nuclear Station Renewed Facility License TMI-20-026, Response to NRC Order EA-20-103, Issuance of Order for Implementation of Additional Security Measures & Fingerprinting for Unescorted Access at Three Mile Island Generating Station Independent Spent Fuel Storage Installation2020-09-15015 September 2020 Response to NRC Order EA-20-103, Issuance of Order for Implementation of Additional Security Measures & Fingerprinting for Unescorted Access at Three Mile Island Generating Station Independent Spent Fuel Storage Installation TMI-20-025, Letter Re Inadvertent Submittal of Exelon Generation Company, LLC - Rev. 95 to NO-AA-10, Quality Assurance Topical Report2020-07-16016 July 2020 Letter Re Inadvertent Submittal of Exelon Generation Company, LLC - Rev. 95 to NO-AA-10, Quality Assurance Topical Report TMI-20-021, Response to Request for Additional Information Regarding License Amendment Request - Deletion of PDTS 3/4.1.4, Handling of Irradiated Fuel with the Fuel Handling Building Crane, and Two Minor Administrative2020-07-0808 July 2020 Response to Request for Additional Information Regarding License Amendment Request - Deletion of PDTS 3/4.1.4, Handling of Irradiated Fuel with the Fuel Handling Building Crane, and Two Minor Administrative TMI-20-015, 2018-2019 Biennial 10 CFR 50.59 Summary Report and 2019 Commitment Revision Summary Report2020-04-30030 April 2020 2018-2019 Biennial 10 CFR 50.59 Summary Report and 2019 Commitment Revision Summary Report TMI-20-016, 2019 Annual Radiological Environmental Operating Report2020-04-30030 April 2020 2019 Annual Radiological Environmental Operating Report TMI-20-017, 2019 Annual Radiological Effluent Release Report2020-04-30030 April 2020 2019 Annual Radiological Effluent Release Report TMI-20-012, Island Nuclear Station, Unit 1 - Submittal of Changes to Technical Specifications Bases2020-04-13013 April 2020 Island Nuclear Station, Unit 1 - Submittal of Changes to Technical Specifications Bases TMI-20-002, Annual Notification of Property Insurance Coverage2020-03-25025 March 2020 Annual Notification of Property Insurance Coverage TMI-20-006, Notification of Revision of Commitment for Amended Post-Shutdown Decommissioning Activities Report (PSDAR) for Three Mile Island, Unit 2 in Accordance with 10 CFR 50.82(a)(7)2020-03-0202 March 2020 Notification of Revision of Commitment for Amended Post-Shutdown Decommissioning Activities Report (PSDAR) for Three Mile Island, Unit 2 in Accordance with 10 CFR 50.82(a)(7) TMI-19-112, Application for Order Approving License Transfer and Conforming License Amendments2019-11-12012 November 2019 Application for Order Approving License Transfer and Conforming License Amendments TMI-19-097, License Amendment Request - License Condition Revision for Removal of Cyber Security Plan Requirements2019-10-31031 October 2019 License Amendment Request - License Condition Revision for Removal of Cyber Security Plan Requirements TMI-18-100, Supplement 2 to License Amendment Request - Proposed Changes to Technical Specifications Sections 1.0, Definitions, and 6.0, Administrative Controls for Permanently Defueled Condition2018-10-29029 October 2018 Supplement 2 to License Amendment Request - Proposed Changes to Technical Specifications Sections 1.0, Definitions, and 6.0, Administrative Controls for Permanently Defueled Condition TMI-18-088, Response to Request for Additional Information: TMI Fall 2017 Steam Generator Tube Inspection Report2018-08-21021 August 2018 Response to Request for Additional Information: TMI Fall 2017 Steam Generator Tube Inspection Report TMI-18-024, Biennial 10 CFR 50.59 and Pdms SAR Report2018-04-24024 April 2018 Biennial 10 CFR 50.59 and Pdms SAR Report TMI-18-044, Transmittal of Radiological Emergency Plans; EP-AA-1009, Revision 28, EP-TM-1000, Revision 0 and EP-AA-1000, Revision 292018-03-29029 March 2018 Transmittal of Radiological Emergency Plans; EP-AA-1009, Revision 28, EP-TM-1000, Revision 0 and EP-AA-1000, Revision 29 TMI-18-004, Decommissioning Funding Status Report for the Three Mile Island Nuclear Station, Unit 22018-03-16016 March 2018 Decommissioning Funding Status Report for the Three Mile Island Nuclear Station, Unit 2 TMI-18-017, Annual Report2018-02-12012 February 2018 Annual Report TMI-17-093, Transmittal of Radiological Emergency Plan Annex Procedure EP-AA-1009, Revision 252017-08-18018 August 2017 Transmittal of Radiological Emergency Plan Annex Procedure EP-AA-1009, Revision 25 TMI-17-060, Request for Approval of Certified Fuel Handler Training Program2017-07-10010 July 2017 Request for Approval of Certified Fuel Handler Training Program TMI-17-051, Supplement to Plant-Specific Path and Schedule for Resolution of Generic Letter 2004-02, Dated May 16, 20132017-05-16016 May 2017 Supplement to Plant-Specific Path and Schedule for Resolution of Generic Letter 2004-02, Dated May 16, 2013 TMI-17-035, Submittal of Changes to Technical Specifications Bases2017-04-13013 April 2017 Submittal of Changes to Technical Specifications Bases TMI-17-034, Submittal of 2016 Commitment Revision Report as Required by SECY-00-0045 (NEI 99-04)2017-03-31031 March 2017 Submittal of 2016 Commitment Revision Report as Required by SECY-00-0045 (NEI 99-04) TMI-17-006, Decommissioning Funding Status Report2017-03-24024 March 2017 Decommissioning Funding Status Report TMI-16-097, Supplemental Information Related to Security Plan, Training and Qualification Plan, and Safeguards Contingency Plan, Revision 172016-10-20020 October 2016 Supplemental Information Related to Security Plan, Training and Qualification Plan, and Safeguards Contingency Plan, Revision 17 TMI-16-090, Submittal of Inspection Plan for Reactor Internals, A/Lai 7 Component Evaluation2016-09-16016 September 2016 Submittal of Inspection Plan for Reactor Internals, A/Lai #7 Component Evaluation 2024-04-29
[Table view] Category:Technical Specifications
MONTHYEARML23033A1032023-01-27027 January 2023 Supplement to License Amendment Request - Proposed Changes to TMl-2 Possession Only License and Technical Specifications ML22087A3942022-03-28028 March 2022 Supplemental Information Supporting License Amendment Request - Proposed Revision to License Conditions and Permanently Defueled Technical Specifications for Permanent Removal of Irradiated Fuel from the Spent Fuel Pool (ISFSI-Only Technica ML21118A0572021-04-13013 April 2021 Submittal of Changes to Technical Specifications Bases ML20352A3812020-12-18018 December 2020 TMI-2 License Transfer Conforming Amendment ML20261H9252020-12-0202 December 2020 Issuance of Amendment No. 299 for Unit 1 Permanently Defueled Emergency Plan and Emergency Action Level Scheme Changes ML19065A1142019-04-18018 April 2019 Issuance of Amendment No. 296 for Unit 1 Changes to Emergency Plan for Post-Shutdown and Permanently Defueled Condition ML19065A2172019-03-0606 March 2019 Supplement - License Amendment Request - Proposed Defueled Technical Specifications and Revised License Conditions for Permanently Defueled Condition ML15225A1582015-10-0101 October 2015 Issuance of Amendment for Temporary Restoration of the Borated Water Storage Tank Cleanup and Recirculation Operation (TAC No. 6504) ML15090A5842015-07-28028 July 2015 Issuance of Amendments Technical Specifications to Modify Reactor Coolant System Pressure Isolation Check Valve Maximum Allowable Leakage Limits ML15141A0582015-07-28028 July 2015 Issuance of Amendments Regarding Emergency Action Level Schemes (TAC Nos. MF4232-MF4251) TMI-15-072, Supplement to License Amendment Request - Modify Reactor Coolant System Pressure Isolation Check Valve Technical Specification Maximum Allowable Leakage Limts2015-06-10010 June 2015 Supplement to License Amendment Request - Modify Reactor Coolant System Pressure Isolation Check Valve Technical Specification Maximum Allowable Leakage Limts TMI-15-064, Supplement to the Application to Revise Technical Specifications to Adopt TSTF-523, Generic Letter 2008-01, Managing Gas Accumulation, Revision 2, Using the Consolidated Line Item Improvement Process2015-05-0707 May 2015 Supplement to the Application to Revise Technical Specifications to Adopt TSTF-523, Generic Letter 2008-01, Managing Gas Accumulation, Revision 2, Using the Consolidated Line Item Improvement Process TMI-13-033, Technical Specification Change Request 352, Revise Technical Specification 3.14.2 and the Licensing Basis Flood Hazard Contained in the Updated Final Safety Analysis Report2013-04-10010 April 2013 Technical Specification Change Request 352, Revise Technical Specification 3.14.2 and the Licensing Basis Flood Hazard Contained in the Updated Final Safety Analysis Report TMI-12-169, Request for Amendment to Eliminate Certain Technical Specification Reporting Requirements2013-02-0404 February 2013 Request for Amendment to Eliminate Certain Technical Specification Reporting Requirements TMI-12-064, Supplemental Response to Request for Additional Information Related to the Proposed Administrative Changes to the Technical Specifications2012-04-11011 April 2012 Supplemental Response to Request for Additional Information Related to the Proposed Administrative Changes to the Technical Specifications TMI-11-171, Response to Request for Additional Information Related to the Proposed Administrative Changes to the Technical Specifications2012-01-20020 January 2012 Response to Request for Additional Information Related to the Proposed Administrative Changes to the Technical Specifications TMI-11-103, License Amendment Request to Revise Technical Specifications to Incorporate Administrative Changes2011-10-18018 October 2011 License Amendment Request to Revise Technical Specifications to Incorporate Administrative Changes TMI-10-035, Technical Specification Change Request No. 351: Maximum Allowable Power with Inoperable Main Steam Safety Valves2010-09-24024 September 2010 Technical Specification Change Request No. 351: Maximum Allowable Power with Inoperable Main Steam Safety Valves ML1003204932010-03-11011 March 2010 License Amendment Technical Specification Changes Adopting TSTF-490-A, Revision 0, Deletion of E-Bar Definition and Revision to Reactor Coolant System Specific Activity Technical Specification ML0927104632009-10-22022 October 2009 Renewed Facility Operating License ML0927104012009-10-22022 October 2009 Issuance of Renewed Facility Operating License No. DPR-50 for Three Mile Island, Unit 1 TMI-09-082, Response to Request for Additional Information Related to License Amendment Request No. 326 to Adopt TSTF-490-A, Revision 0, Deletion of E Bar Definition and Revision to Reactor Coolant System Specific Activity Technical....2009-07-0202 July 2009 Response to Request for Additional Information Related to License Amendment Request No. 326 to Adopt TSTF-490-A, Revision 0, Deletion of E Bar Definition and Revision to Reactor Coolant System Specific Activity Technical.... ML0831201222008-11-0606 November 2008 License Amendment Request No. 326 to Adopt TSTF-490-A, Revision 0, Deletion of E Bar Definition and Revision to Reactor Coolant System Specific Activity Technical Specification Using the Consolidated Line Item Improvement.. ML0828001742008-09-29029 September 2008 Technical Specification Change Request No. 342 Control Rod Drive Control System Upgrade and Elimination of the Axial Power Shaping Rods ML0827402962008-09-15015 September 2008 Supplement: Technical Specification Change Request for Technical Specification Change Request (Tscr) No. 86 Deletion of Technical Specification Sections 6.5, Review and Audit ML0824703052008-08-28028 August 2008 Technical Specifications, TSTF Change Traveler TSTF-479 & TSTF-497 ML0823907072008-08-21021 August 2008 Revised T.S. Pages Oyster Creek Nuclear Generating Station and Peach Bottom Atomic Power Station, Unit 3-Correction to Facility Operating Licenses ML0821301362008-07-25025 July 2008 Braidwood/Byron/Clinton/Dresden/Lasalle/Oyster Creek/Peach Bottom/Quad Cities/Three Mile Island - Tech Spec Pages for Amds to Change TS Unit Staff Qualifications Education and Experience Eligibility Requirements for Licensed Operators RA-08-024, Amergen, Energy LLC, License Amendment Request to Remove References to NRC Generic Letter 82-12, Nuclear Power Plant Staff Working Hours.2008-04-21021 April 2008 Amergen, Energy LLC, License Amendment Request to Remove References to NRC Generic Letter 82-12, Nuclear Power Plant Staff Working Hours. ML0809101272008-04-16016 April 2008 Technical Specifications to Amendment ML0807700842008-03-14014 March 2008 Additional Information for Technical Specifications Regarding Control Room Envelope Habitability in Accordance with TSTF-448, Revision 3 RS-08-012, Amergen Company, Request for Amendment to Administrative Controls Section of Technical Specifications2008-02-28028 February 2008 Amergen Company, Request for Amendment to Administrative Controls Section of Technical Specifications ML0727100352007-09-27027 September 2007 Tech Spec Pages for Amendment 261 Regarding Steam Generator Tube Integrity Using the Consolidated Line Item Improvement Process and Generic Letter 2006-01 ML0726904252007-09-26026 September 2007 Tech Spec Pages for Amendment 260 Regarding Relocation of Technical Specification Requirements for Refueling and Spent Fuel Pool Area Radiation Monitors ML0725402542007-09-0404 September 2007 Additional Information - Technical Specification Change Request No. 331: Application for Technical Specification Improvement Regarding Steam Generator Tube Integrity RS-07-078, Amergen - License Amendment Request to Change Technical Specification Unit Staff Qualifications Education and Experience Eligibility Requirements for Licensed Operators2007-07-19019 July 2007 Amergen - License Amendment Request to Change Technical Specification Unit Staff Qualifications Education and Experience Eligibility Requirements for Licensed Operators ML0718003192007-06-29029 June 2007 Tech Spec Pages for Amendment 259, One-Time Type a Test Interval Extension ML0715606022007-06-0505 June 2007 Response to Request for Additional Information Concerning Technical Specifications Change Request No. 334 - One-Time Type a Test Interval Extension ML0715202332007-05-31031 May 2007 Response to Request for Additional Information - Technical Specification Change Request No. 331 Application for Technical Specification Improvement Regarding Steam Generator Tube Integrity ML0715202292007-05-31031 May 2007 Additional Information - Technical Specification Change Request No. 333, Relocation of Technical Specification Requirements for Refuel and Spent Fuel Pool Area Radiation Monitors. ML0712302682007-04-27027 April 2007 Submittal of Changes to Technical Specification Bases ML0708609682007-03-22022 March 2007 Technical Specification Change Request No. 335, Incorporating Revised Limit or the Variable Low Reactor Coolant System Pressure-Temperature Core Protection Safety Limit ML0628303312006-10-0606 October 2006 Response to Request for Additional Information, Technical Specification Change Request No. 331: Application for Technical Specification Improvement Regarding Steam Generator Tube Integrity ML0626800402006-09-15015 September 2006 Technical Specifications Change Request No. 334 - One-Time Type a Test Interval Extension ML0614202942006-05-15015 May 2006 Technical Specification Change Request No. 331 - Application for Technical Specification Improvement Regarding Steam Generator Tube Integrity ML0610100612006-04-0808 April 2006 Technical Specification Page Allowed Outage Time Extension from 7 Days to 10 Days for Emergency Diesel Generator EG-Y-1A ML0528702192005-10-13013 October 2005 Issuance of Amendment Elimination of Containment Equipment Hatch Closure Requirement During Refueling, Technical Specifications ML0522703622005-08-12012 August 2005 Tech Spec Pages for Amendment 256 Missed Surveillance Criteria Requirements and Addition of a Technical Specifications Bases Control Program ML0522304032005-08-10010 August 2005 Technical Specification Pages Extension of Reactor Trip System and Reactor Trip Device Functional Test Intervals ML0517506582005-06-17017 June 2005 Tech Spec Pages for Amendment - Monthly Operating Reports and Annual Occupational Radiation Reports 2023-01-27
[Table view] |
Text
10 50.90 April 11, 2 U Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC Three Mile Island Nuclear Station, Unit 1 Renewed Facility Operating License No.
NRC Docket No.50-289
Subject:
Three Mile Island Unit 1 Supplemental Response to Request for Additional Information Related to the Proposed Administrative Changes to the Technical Specifications
References:
(1)Letter from P.Bamford (U.S.Nuclear Regulatory Commission) to M.J.Padlio (Exelon Generation Company, LLC),"Three Mile Island Nuclear Station, Unit 1 Request for Additional Information Regarding Proposed License Amendment Revising Technical Specifications to Incorporate Administrative Changes" (TAC NO.ME7357)" dated December 19, 2011 (ML113360596)
Letter from M.D.Jesse (Exelon Generation Company, LLC)to U.S.Nuclear Regulatory Commission,'Three Mile Island Unit 1 Response to Request for Additional Information Related to Proposed Administrative Changes to the Technical Specifications" dated January 20,2012 (ML12020A091)
USNRC request for additional information (RAI), Reference 1, included several observations regarding the eXisting Three Mile Island, Unit 1 (TMI, Unit 1)Technical Specifications (TSs).The observations included the following statement:
"...the NRC staff notes that TS 5.1.1 refers to a"weather tower" depicted on Figure 5-3.Both the existing and revised Figure 5-3 depictions show a"weather station." Exelon should consider making this terminology consistent." In the Reference 2 RAI response, TMI, Unit 1 requested a revision to TS 5.1.1 on page 5-1 to state"weather station" consistent with Figure 5-3 and the NRC observation.
Reviews of design documents, station drawings, and systems descriptions determined the most correct terminology for the meteorological tower designation in TS 5.1.1 is a"weather tower." The reviews concluded that both a weather tower and a weather station are located at TMI, Unit 1 in the same vicinity, as shown on TS Figure 5-3.Further, the reviews clarified that the weather tower is where the meteorological sensors are located and the weather station houses the signal conditioning and recording instruments.
Therefore, TMI, Unit 1 withdraws the request to update TS 5.1.1 on page 5-1 to state"weather station" in the Reference 2 submittal.
Attachment 1 provides the revised TS page mark-ups showing the withdrawn change.Attachment 2 provides the revised page showing the proposed changes.
U.S.Nuclear Regulatory Commission April 11, 2012 2 TMI, Unit 1 has determined that the information provided in response to this request for additional information does not impact the conclusions of the No Significant Hazards Consideration or Environmental Consideration as stated in the original submittal dated October 18, 2011 (ML112911548).
Additionally, there are no regulatory commitments contained in this submittal.
Should you have any questions concerning this letter, ple,::lse contact Ms.Wendy Croft at (610)765-5726.I declare under penalty of perjury that the foregoing is true and correct.Executed on the 11 th day of April,2012.
!\!I;r-h<:>",1 D.Jesse Director, LicensinglQn egulatory Affairs Exelon Generation Company, LLC Attachments:
1.2.Proposed Technical Specification Page (Mark-Up)RevisedTechnicalSpecification Page cc: USNRC Region I, Regional Administrator USNRC Project Manager, TMI, Unit 1 USNRC Senior Resident Inspector, TMI, Unit 1 Director, Bureau of Radiation Protection, PA Department of Environmental Resources Chairman, Board of County Commissioners, Dauphin County, PA Chairman, Board of Supervisors, Londonderry Township, PA R.R.Janati, Commonwealth of Pennsylvania ATTACHMENT 1 Proposed Technical Specification Page (Mark-Up)Three Mile Island Generating Station, Unit 1 Renewed Facility Operating License No.CPR-50 REVISED TECHNICAL SPECIFICATIONS PAGE 5-1 DESIGN FEATURES 5.1 Applicability Applies to the location and extent of the exclusion boundary, restricted area, and low population zone.To define the above by location and distance description.
5.1.1 The Three Mile Island Nuclear Station Unit 1 is located in an area of low population density about ten miles southeast of Harrisburg, PA.It is in Londonderry Township of Dauphin County, Pennsylvania, about two andhalf miles north of the southern tip of Dauphin County, where Dauphin is coterminal with York and Lancaster Counties.The station is located on an island approximately three miles in length..ru stream from York Haven Dam.Figure is an extended plot plan of the site showing the plant orientation and immediate surroundings.
The Exclusion Area as defined in 10 CFR 100.3, is a 2,000 ft.radius, including portions of Three Mile Island, the river surface around it,\,nd a portion of Shelley Island, which is owned by AmerGen Energy eompally, lle.The minimum distance of 2,000 ft.'-------'occurs on the shore.in direction from the shown on Figure for the Exclusion Area.Figure 5-3 showing the physical location of the fence defines the"Restricted Area" surrounding the plant.The minimum distance of the"Restricted Area" is approximately 560 feet and is from the centerline of the TMI Unit 2 Reactor Building to a point on the westerly shoreline of Three Mile Island.The minimum distance to the outer boundary of the low population zone is two miles as shown on T.S.Figure 5-2, which also depicts the site topography for a radius of five miles.T.S.Figure 5-3 depicts the locations of gaseous effluent release points and liquid effluent outfalls (as tabularized on page 5-10), and the meteorological tower location (designated as'weather tower'on the figure).5-1 Amendment No.72,137, 149,2+e-ATTACHMENT 2 Revised Technical Specifications Page Three Mile Island Generating Station, Unit 1 Renewed Facility Operating License No.DPR-50 REVISED TECHNICAL SPECIFICATIONS PAGE 5-1 5.0 DESIGN FEATURES 5.1 Applicability Applies to the location and extent of the exclusion boundary, restricted area, and low population zone.Objective To define the above by location and distance description.
Specification 5.1.1 The Three Mile Island Nuclear Station Unit 1 is located in an area of low population density about ten miles southeast of Harrisburg, PA.It is in Londonderry Township of Dauphin County, Pennsylvania, about two andhalf miles north of the southern tip of Dauphin County, where Dauphin is coterminal with York and Lancaster Counties.The station is located on an island approximately three miles in length situated in the Susquehanna River upstream from York Haven Dam.Figure 5-1 is an extended plot plan of the site showing the plant orientation and immediatesurroundings.The Exclusion Area as defined in 10 CFR 100.3, is a 2,000 ft.radius, including portions of Three Mile Island, the river surface around it, and a portion of Shelley Island, which is owned by Exelon Generation Company, LLC.The minimum distance of 2,000 ft.occurs on the shore of the mainland in a due easterly direction from the plant as shown on Figure 5-1 for the Exclusion Area.Figure 5-3 showing the physical location of the fence defines the"Restricted Area" surrounding the plant.The minimum distance of the"RestrictedArea" is approximately 560 feet and is from the centerline of the TMI Unit 2 Reactor Building to a point on the westerly shoreline of Three Mile Island.The minimum distance to the outer boundary of the low population zone is two miles as shown on T.S.Figure 5-2, which also depicts the site topography for a radius of five miles.T.S.Figure 5-3 depicts the locations of gaseous effluent release points and liquid effluent outfalls (as tabularized on page 5-10), and the meteorological tower location (designated as'weather tower'on the figure).5-1 Amendment No.72,137,149,218