NL-15-0606, Independent Spent Fuel Storage Installation (ISFSI) - Registration of Spent Fuel Cask Use: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
Line 3: Line 3:
| issue date = 04/13/2015
| issue date = 04/13/2015
| title = Independent Spent Fuel Storage Installation (ISFSI) - Registration of Spent Fuel Cask Use
| title = Independent Spent Fuel Storage Installation (ISFSI) - Registration of Spent Fuel Cask Use
| author name = Taber B K
| author name = Taber B
| author affiliation = Southern Co, Southern Nuclear Operating Co, Inc
| author affiliation = Southern Co, Southern Nuclear Operating Co, Inc
| addressee name =  
| addressee name =  

Revision as of 00:33, 21 June 2019

Independent Spent Fuel Storage Installation (ISFSI) - Registration of Spent Fuel Cask Use
ML15118A875
Person / Time
Site: Vogtle, 07201039, Holtec  Southern Nuclear icon.png
Issue date: 04/13/2015
From: Taber B
Southern Co, Southern Nuclear Operating Co
To:
Document Control Desk, NRC/NMSS/SFST
References
NL-15-0606
Download: ML15118A875 (2)


Text

B. Keith Taber Vice President Vogtle -Units I & 2 April 13, 2015 Southern Nuclear Operating Company, Inc. 7821 River Road Waynesboro, GA 30830 Tel 706.826.3151 Docket Nos.: 50-424 50-425 72-1039 AlTN: Document Control Desk SOUTHERN A COMPANY NL-15-0606 Director, Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety Safeguards U. S. Nuclear Regulatory Commission Washington, D. C. 20555-0001 Vogtle Electric Generating Plant -Units 1 and 2 Registration of Soent Fuel Cask Use Ladies and Gentlemen:

Southern Nuclear Operating Company (SNC) operates the Vogtle Electric Generating Plant (Vogtle) Independent Spent Fuel Storage Installation (ISFSI) in accordance with the general license provisions of 1 0 CFR 72.21 0. The requirements of 10 CFR 72.212(b)(2) include the registration of a spent fuel cask within 30 days of using a cask for the storage of spent nuclear fuel. Accordingly, SNC provides the following registration information for HI-STORM 100 spent fuel cask systems placed into storage in the Vogtle ISFSI during the past 30 days. Cask Certificate:

Cask Model: MPC Serial Number: Overpack Serial Number: Number of Fuel Bundles: Placed in Service: Cask Certificate:

Cask Model: MPC Serial Number: Overpack Serial Number: Number of Fuel Bundles: Placed in Service: 72-1 014 , Amendment 9 HI-STORM 100S, Version B 0343 218-824 32 March 17, 2015 72-1014, Amendment 9 HI-STORM 100S, Version B 0337 218-818 32 March 27 , 2015 Cask Certificate:

Cask Model: MPC Serial Number: Overpack Serial Number: Number of Fuel Bundles: Placed in Service: 72-1014, Amendment 9 HI-STORM 1 OOS, Version B 0338 218-819 32 Aprii3,2015 This letter contains no NRC commitments.

If you have any questions, please contact Ken McElroy at (205) 992-7369.

B. Keith Taber Vice President Vogtle 1& 2 BKT/ KCW cc: Southern Nuclear Operating Company Mr. S. E. Kuczynski, Chairman, President

& CEO Mr. D. G. Bast, Executive Vice President

& Chief Nuclear Officer Mr. D. R. Madison, Vice President-Fleet Operations Mr. M. D. Meier, Vice President-Regulatory Affairs Mr. B. K. Taber, Vice President-Vogtle 1 & 2 Mr. B. J. Adams, Vice President-Engineering Mr. G.W. Gunn, Regulatory Affairs Manager-Vogtle 1 & 2 RType: CVC7000 U.S. Nuclear Regulatory Commission Mr. V. M. McCree, Regional Administrator Mr. R. E. Martin, NRR Senior Project Manager-Vogtle 1 & 2 Mr. l. M. Cain, Senior Resident Inspector-Vogtle 1 & 2 Mr. R. P. Carrion, Senior Reactor Inspector, Region II