ML12090A668: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 1: | Line 1: | ||
{{Adams | |||
| number = ML12090A668 | |||
| issue date = 01/30/2012 | |||
| title = Entergy Pre-Filed Hearing Exhibit ENT000381, NL-12-032, Letter from F. Dacimo, Entergy, to NRC, Correction to Previous Response Regarding Unit 1 Buried Piping (Jan. 30 2012) | |||
| author name = | |||
| author affiliation = Entergy Nuclear Northeast | |||
| addressee name = | |||
| addressee affiliation = NRC/Document Control Desk, NRC/NRR | |||
| docket = 05000247, 05000286 | |||
| license number = DPR-026, DPR-064 | |||
| contact person = SECY RAS | |||
| case reference number = RAS 22150, 50-247-LR, 50-286-LR, ASLBP 07-858-03-LR-BD01, NL-12-032 | |||
| package number = ML12090A648 | |||
| document type = Legal-Pre-Filed Exhibits | |||
| page count = 2 | |||
}} | |||
=Text= | |||
{{#Wiki_filter:ENT000381 Submitted: | |||
March 30 , 2012 ---Entergy: Entergy Nuclear Northeast Indian Point Energy Center 450 Broadway, GSB P,O, Box 249 Buchanan, NY 10511-0249 Tel (914) 254-2055 NL-12-032 January 30, 2012 Fred Dacimo Vice President Operations License Renewal U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 | |||
==SUBJECT:== | |||
==REFERENCE:== | |||
==Dear Sir or Madam:== | |||
Correction to Previous Response Regarding Unit 1 Buried Piping Indian Point Nuclear Generating Unit Nos. 1, 2 & 3 Docket Nos. 50-003, 50-247 and 50-286 License Nos. DPR-5, DPR-26 and DPR-64 1. NRC Letter dated December 30, 2008, "Request for Additional Information for the Review of the Indian Point Nuclear Generating Unit Numbers 2 and 3, License Renewal Application | |||
-Miscellaneous Items" 2. Entergy letter (NL-09-018)," Reply to Request for Additional Information | |||
-Miscellaneous Items," dated January 27,2009 3. NRC Letter dated May 20, 2009, "Request for Additional Information for the Review of the Indian Point Nuclear Generating Unit Numbers 2 and 3, License Renewal Application | |||
-Offsite Power, Refueling Cavity, and Unit 2 auxiliary Feedwater Pump Room Fire Event" 4. Entergy letter (NL-09-079)," Reply to Request for Additional Information Regarding Offsite Power, Refueling Cavity, and Unit 2 Auxiliary Feedwater Pump Room Fire Event," dated June 12, 2009 Entergy Nuclear Operations, Inc is providing a correction, as shown in Attachment 1 and Attachment 2, the response provided references 2 and 4 for license renewal application 1 Entergy an to Reference 2 added components to the scope of license renewal for the auxiliary feedwater pump room fire event Reference 4 provided additional information on aging management review results for added components. In these RAI's, the portion of the Unit 1 river water system from the pump discharge to the intertie to Indian Point Unit 2 service water system was added to the scope of license renewal. The components in this portion of the river water system were added the new LRA Table 1 table identified only outdoo r as the a ENT000381 Submitted: | |||
March 30 , 2012 ---Entergy: Entergy Nuclear Northeast Indian Point Energy Center 450 Broadway, GSB P,O, Box 249 Buchanan, NY 10511-0249 Tel (914) 254-2055 NL-12-032 January 30, 2012 Fred Dacimo Vice President Operations License Renewal U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 | |||
==SUBJECT:== | |||
==REFERENCE:== | |||
==Dear Sir or Madam:== | |||
Correction to Previous Response Regarding Unit 1 Buried Piping Indian Point Nuclear Generating Unit Nos. 1, 2 & 3 Docket Nos. 50-003, 50-247 and 50-286 License Nos. DPR-5, DPR-26 and DPR-64 1. NRC Letter dated December 30, 2008, "Request for Additional Information for the Review of the Indian Point Nuclear Generating Unit Numbers 2 and 3, License Renewal Application | |||
-Miscellaneous Items" 2. Entergy letter (NL-09-018)," Reply to Request for Additional Information | |||
-Miscellaneous Items," dated January 27,2009 3. NRC Letter dated May 20, 2009, "Request for Additional Information for the Review of the Indian Point Nuclear Generating Unit Numbers 2 and 3, License Renewal Application | |||
-Offsite Power, Refueling Cavity, and Unit 2 auxiliary Feedwater Pump Room Fire Event" 4. Entergy letter (NL-09-079)," Reply to Request for Additional Information Regarding Offsite Power, Refueling Cavity, and Unit 2 Auxiliary Feedwater Pump Room Fire Event," dated June 12, 2009 Entergy Nuclear Operations, Inc is providing a correction, as shown in Attachment 1 and Attachment 2, the response provided references 2 and 4 for license renewal application 1 Entergy an to Reference 2 added components to the scope of license renewal for the auxiliary feedwater pump room fire event Reference 4 provided additional information on aging management review results for added components. In these RAI's, the portion of the Unit 1 river water system from the pump discharge to the intertie to Indian Point Unit 2 service water system was added to the scope of license renewal. The components in this portion of the river water system were added the new LRA Table 1 table identified only outdoo r as the a is buried and line items of piping and bolting with 3.4.2-5-11-IP2. | |||
Appendix B.1.6 of the license rer water system in the list of systems containing con Tanks Inspection Program. The buried piping in 1 management review had been included and reme established in response to the industry initiative 0 If you have any questions, or require additional in at 914-254-6710. | |||
I declare under penalty of perjury that the foregoil 3Q) 2d 1 :z-}} |
Revision as of 09:27, 18 March 2019
ML12090A668 | |
Person / Time | |
---|---|
Site: | |
Issue date: | 01/30/2012 |
From: | Entergy Nuclear Northeast |
To: | Document Control Desk, Office of Nuclear Reactor Regulation |
SECY RAS | |
Shared Package | |
ML12090A648 | List: |
References | |
RAS 22150, 50-247-LR, 50-286-LR, ASLBP 07-858-03-LR-BD01, NL-12-032 | |
Download: ML12090A668 (2) | |
Text
ENT000381 Submitted:
March 30 , 2012 ---Entergy: Entergy Nuclear Northeast Indian Point Energy Center 450 Broadway, GSB P,O, Box 249 Buchanan, NY 10511-0249 Tel (914) 254-2055 NL-12-032 January 30, 2012 Fred Dacimo Vice President Operations License Renewal U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001
SUBJECT:
REFERENCE:
Dear Sir or Madam:
Correction to Previous Response Regarding Unit 1 Buried Piping Indian Point Nuclear Generating Unit Nos. 1, 2 & 3 Docket Nos.50-003, 50-247 and 50-286 License Nos. DPR-5, DPR-26 and DPR-64 1. NRC Letter dated December 30, 2008, "Request for Additional Information for the Review of the Indian Point Nuclear Generating Unit Numbers 2 and 3, License Renewal Application
-Miscellaneous Items" 2. Entergy letter (NL-09-018)," Reply to Request for Additional Information
-Miscellaneous Items," dated January 27,2009 3. NRC Letter dated May 20, 2009, "Request for Additional Information for the Review of the Indian Point Nuclear Generating Unit Numbers 2 and 3, License Renewal Application
-Offsite Power, Refueling Cavity, and Unit 2 auxiliary Feedwater Pump Room Fire Event" 4. Entergy letter (NL-09-079)," Reply to Request for Additional Information Regarding Offsite Power, Refueling Cavity, and Unit 2 Auxiliary Feedwater Pump Room Fire Event," dated June 12, 2009 Entergy Nuclear Operations, Inc is providing a correction, as shown in Attachment 1 and Attachment 2, the response provided references 2 and 4 for license renewal application 1 Entergy an to Reference 2 added components to the scope of license renewal for the auxiliary feedwater pump room fire event Reference 4 provided additional information on aging management review results for added components. In these RAI's, the portion of the Unit 1 river water system from the pump discharge to the intertie to Indian Point Unit 2 service water system was added to the scope of license renewal. The components in this portion of the river water system were added the new LRA Table 1 table identified only outdoo r as the a ENT000381 Submitted:
March 30 , 2012 ---Entergy: Entergy Nuclear Northeast Indian Point Energy Center 450 Broadway, GSB P,O, Box 249 Buchanan, NY 10511-0249 Tel (914) 254-2055 NL-12-032 January 30, 2012 Fred Dacimo Vice President Operations License Renewal U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001
SUBJECT:
REFERENCE:
Dear Sir or Madam:
Correction to Previous Response Regarding Unit 1 Buried Piping Indian Point Nuclear Generating Unit Nos. 1, 2 & 3 Docket Nos.50-003, 50-247 and 50-286 License Nos. DPR-5, DPR-26 and DPR-64 1. NRC Letter dated December 30, 2008, "Request for Additional Information for the Review of the Indian Point Nuclear Generating Unit Numbers 2 and 3, License Renewal Application
-Miscellaneous Items" 2. Entergy letter (NL-09-018)," Reply to Request for Additional Information
-Miscellaneous Items," dated January 27,2009 3. NRC Letter dated May 20, 2009, "Request for Additional Information for the Review of the Indian Point Nuclear Generating Unit Numbers 2 and 3, License Renewal Application
-Offsite Power, Refueling Cavity, and Unit 2 auxiliary Feedwater Pump Room Fire Event" 4. Entergy letter (NL-09-079)," Reply to Request for Additional Information Regarding Offsite Power, Refueling Cavity, and Unit 2 Auxiliary Feedwater Pump Room Fire Event," dated June 12, 2009 Entergy Nuclear Operations, Inc is providing a correction, as shown in Attachment 1 and Attachment 2, the response provided references 2 and 4 for license renewal application 1 Entergy an to Reference 2 added components to the scope of license renewal for the auxiliary feedwater pump room fire event Reference 4 provided additional information on aging management review results for added components. In these RAI's, the portion of the Unit 1 river water system from the pump discharge to the intertie to Indian Point Unit 2 service water system was added to the scope of license renewal. The components in this portion of the river water system were added the new LRA Table 1 table identified only outdoo r as the a is buried and line items of piping and bolting with 3.4.2-5-11-IP2.
Appendix B.1.6 of the license rer water system in the list of systems containing con Tanks Inspection Program. The buried piping in 1 management review had been included and reme established in response to the industry initiative 0 If you have any questions, or require additional in at 914-254-6710.
I declare under penalty of perjury that the foregoil 3Q) 2d 1 :z-