ML12090A660

From kanterella
Jump to navigation Jump to search
Entergy Pre-Filed Hearing Exhibit ENT000375, Curriculum Vitae of Robert C. Lee
ML12090A660
Person / Time
Site: Indian Point  
Issue date: 03/30/2012
From: Richard Lee
Entergy Nuclear Operations
To:
Atomic Safety and Licensing Board Panel
SECY RAS
Shared Package
ML12090A648 List:
References
RAS 22150, 50-247-LR, 50-286-LR, ASLBP 07-858-03-LR-BD01
Download: ML12090A660 (2)


Text

ROBERT C. LEE EDUCATION Bachelor of Science in Mechanical Engineering City College of New York, 1973 Post graduate courses in Mechanical Engineering Rensselaer Polytechnic Institute, Hartford Graduate Center, 1974-5 LICENSE New York State Professional Engineer, License #61749 EXPERIENCE November 2008 Senior Mechanical Engineer, Code Programs to Current Entergy Nuclear Operations Indian Point 2 and 3, Buchanan, NY 10511 Developed and implemented site Buried Piping and Tank Inspection and Monitoring Program. Assumed ownership of the following ASME Code Programs:

Inservice Testing, Primary Containment Leakage Rate Testing and Pressure Testing.

November 2000 Senior Engineer, Mechanical Design to November 2008 Entergy Nuclear Northeast Indian Point 2 & 3, Buchanan, NY October 1984 Senior Engineer, Mechanical Design to November 2000 New York Power Authority 123 Main Street, White Plains, NY 10601 (1984 - 1995)

Indian Point 3 Nuclear Power Plant, Buchanan, NY 10511 (1995 - 2000)

Design Engineer providing onsite engineering support on design basis issues, NRC inspections, NRC bulletins and generic letters, short and intermediate term engineering projects. Prepared plant modification packages for the installation of replacement hydrogen coolers, replacement pump mechanical seals, hydrogen dryers, etc. Responsible Engineer for Service Water and Weld Channel and Containment Penetration Pressurization and Isolation Valve Seal Water Systems Design Basis Documents, cognizant of all updates of the documents. (1995 -

2000)

Lead Design Engineer responsible for the preparation of multi-discipline design modification packages for original plant equipment replacements and/or new installations. Specific tasks included modification proposal and scope definition, equipment technical specification, procurement support through equipment delivery, and field engineering support during installation and testing. Major equipment installed included reactor water clean-up pumps, emergency service water pumps, valves, intake travelling water screens and strainers. (1984 - 1995)

Robert C. Lee Page 2 ENT000375 Submitted: March 30, 2012

September 1981 Mechanical Engineer, Mechanical Design to October 1984 New York Power Authority 123 Main Street, White Plains, NY 10601 Lead Design Engineer for power generating station circulating water system upgrade modification, successfully applying adjustable speed (1250 HP) motor drives. Developed technical specifications for replacement circulating water pumps, test program for hydraulic model test laboratory and mechanical installation specifications. Provided on-site engineering support for equipment installation and testing.

Lead design engineer for nuclear power generating station cooling water angled intake screen system conceptual design study. Provided engineering oversight of A/E's development of a conceptual design of an angled screen system for cooling water intake for cost estimating and presentation to environmental regulatory agencies.

January 1979 Mechanical Engineer to March 1981 Bendix Corporation, Electric Power Division 118 State Highway 35, Eatontown, NJ 07724 Responsible for the mechanical design of compact rotating electric power generating and static controls systems for application in commercial and military aircraft and land vehicles. Work included: structural design, thermal analysis, failure analysis, material and component specification, equipment qualification, test program development, test fixture design and proposal writing.

December 1975 Nuclear Steam Supply Engineer, Reactor Design to January 1979 Combustion Engineering, Power Systems Division 1000 Prospect Hill Road, Windsor, CT 06095 Performed dynamic analysis of nuclear reactor internals and core components in accordance with Nuclear Regulatory Commission requirements. Efforts included finite element buckling analyses of core support barrel, computer model simulation of a reactor internals for the determination of the dynamic response to loads imposed by postulated coolant pipe breaks and seismic excitations; computation of flange stiffnesses, pressure and force time histories.

July 1973 Analytical Engineer, Structural Design to August 1975 Pratt & Whitney Aircraft 400 Main Street, East Hartford, CT 06108 Performed vibration analyses on jet engine rotor frames and components; conducted critical speed and forced response studies of industrial gas turbines and jet engines. Co-ordinated a static structure load test program to evaluate the flight worthiness of the JT8D refan (Quiet Engine).